HCALORY TS-M

Hcalory TS-M termovizijska kamera s multimetrom - uputstvo za upotrebu

Model: TS-M

1. Uvod

This user manual provides detailed instructions for the safe and effective operation of your Hcalory TS-M Thermal Imaging Camera with Multimeter. This device integrates thermal imaging capabilities with a professional-grade digital multimeter, offering a versatile tool for diagnostics and measurement in various applications. Please read this manual thoroughly before using the device and retain it for future reference.

2. Sigurnosne informacije

Always observe the following safety precautions to prevent injury and avoid damage to the instrument or the equipment under test.

3. Sadržaj paketa

Verify that all items listed below are present and undamaged upon opening the package. If any item is missing or damaged, contact your retailer.

Contents of Hcalory TS-M package including thermal imager, manual, cables, probes, and case.

Slika 3.1: Sadržaj paketa
The image displays the complete contents of the Hcalory TS-M package. These include (1) an EV Toolkit (carrying case), (2) the Instruction Manual, (3) a USB Charging Cable/Probe, (4) the Thermal Imaging Multimeter 2-in-1 device, (5) Multimeter Probes, and (6) a Macro Magnetic Lens.

  1. Thermal Imaging Multimeter (Model TS-M)
  2. Multimeter Test Leads (Probes)
  3. USB kabl za punjenje
  4. Macro Magnetic Lens
  5. Uputstvo za upotrebu
  6. Carrying Case (EV Toolkit)

4. Proizvod je gotovview

The Hcalory TS-M combines a high-resolution thermal imager with a full-function digital multimeter, designed for efficiency and accuracy in various diagnostic tasks. Its robust construction ensures durability in demanding environments.

Prednje i zadnje view of the Hcalory TS-M Thermal Imaging Multimeter.

Figure 4.1: Device Front and Back View
This image shows the Hcalory TS-M device from both the front and back. The front features the display screen, control buttons, and multimeter input jacks. The back includes the IR camera lens and a macro lens attachment point.

Ključne karakteristike:

5. Podešavanje

5.1 Punjenje uređaja

Before first use, fully charge the Hcalory TS-M. Connect the provided USB charging cable to the device's USB-C port and to a standard USB power adapter (not included) or a computer USB port. The charging indicator on the device will show charging status.

Hcalory TS-M device connected to a charger, showing battery icon and 7 hours of battery life.

Slika 5.1: Punjenje uređaja
The image illustrates the Hcalory TS-M connected via its USB-C port for charging. The display indicates a full battery and an estimated operational time of 7 hours, powered by its 1500 mAh battery.

5.2 Attaching Test Leads

For multimeter functions, insert the red test lead into the VΩ(+) jack and the black test lead into the COM(-) jack. Ensure a secure connection.

5.3 Attaching Macro Lens (Optional)

For detailed thermal inspection of small components, attach the magnetic macro lens to the designated area on the back of the device, over the IR camera lens. The magnetic attachment ensures easy installation and removal.

Hcalory TS-M with a magnetic macro lens attached, showing magnified thermal images.

Figure 5.2: Macro Lens Attachment
This image demonstrates the Hcalory TS-M with its magnetic macro lens attached to the rear. The display shows a comparison of thermal images, highlighting the enhanced detail provided by the 5x magnification of the macro lens compared to 1x without it, useful for pinpoint accuracy on small components.

6. Uputstvo za upotrebu

6.1 Uključivanje/isključivanje napajanja

Pritisnite i držite dugme za napajanje (obično označeno krugom i vertikalnom linijom) da biste uključili ili isključili uređaj.

6.2 Thermal Imaging Mode

Upon powering on, the device typically defaults to thermal imaging mode. The screen will display a thermal image of the environment. Use the navigation buttons (up, down, left, right, OK) to access menus and adjust settings such as color palettes, emissivity, and temperature units.

User holding Hcalory TS-M, displaying a thermal image of an engine.

Figure 6.1: Thermal Imaging in Use
The image shows a user holding the Hcalory TS-M, with its screen displaying a thermal image of an engine. This illustrates the device's capability to provide immediate visual temperature data, aiding in quick problem diagnosis.

6.2.1 TISR Resolution Enhancement

The Hcalory TS-M features TISR (Thermal Imaging Super Resolution) technology, enhancing the thermal image resolution to 240x240 pixels for greater clarity. This feature can typically be toggled on or off via the device's menu settings to suit different inspection needs.

Comparison of thermal images with TISR on (240x240) and TISR off (64x64).

Figure 6.2: TISR Resolution Comparison
This image demonstrates the impact of TISR technology. On the left, a thermal image with TISR enabled shows a resolution of 240x240, providing significantly more detail. On the right, the same scene with TISR off displays a lower resolution of 64x64, highlighting the clarity improvement offered by the enhanced resolution feature.

6.3 Režim multimetra

To switch to multimeter mode, use the mode selection button or navigate through the menu. Once in multimeter mode, select the desired measurement function (e.g., AC Voltage, DC Voltage, Resistance, Continuity, Diode Test) using the function dial or buttons. Connect the test leads to the circuit under test as appropriate for the selected function.

Hcalory TS-M with multimeter probes connected to a circuit board.

Figure 6.3: Multimeter Functionality
The image shows the Hcalory TS-M in use as a multimeter, with its probes connected to a circuit board. The screen displays electrical measurement readings, demonstrating its capability for precise electrical diagnostics.

6.3.1 Common Multimeter Functions:

7. Održavanje

7.1 Čišćenje

Obrišite uređaj casing s oglasomamp cloth and mild detergent. Do not use abrasive cleaners or solvents. Ensure the device is powered off and disconnected from any power source before cleaning. Do not immerse the device in water.

7.2 Njega baterija

The device contains a rechargeable lithium-ion battery. For optimal battery life, avoid fully discharging the battery frequently. If storing the device for an extended period, charge it to approximately 50% every few months.

7.3 Fuse Replacement (Multimeter)

The multimeter functions are protected by internal fuses. If a current measurement function fails, the fuse may need replacement. Refer to the specifications for the correct fuse type and rating. Fuse replacement should only be performed by qualified personnel.

8. Otkrivanje problema

ProblemMogući uzrokRješenje
Uređaj se ne uključuje.Slaba ili prazna baterija.Napunite uređaj pomoću priloženog USB kabla.
Termalna slika je mutna ili nejasna.Lens is dirty; TISR is off.Clean the IR lens with a soft cloth. Enable TISR in settings.
Multimeter readings are incorrect or zero.Incorrect function selected; test leads not properly connected; blown fuse.Verify function selection. Ensure leads are securely connected. Check and replace fuse if necessary (qualified personnel only).
Uređaj se zamrzava ili prestaje reagirati.Softverski kvar.Perform a soft reset by holding the power button for 10-15 seconds. If persistent, a factory reset may be required (refer to advanced settings).

9. Specifikacije

FeatureSpecifikacija
ModelTS-M
BrandKALORIJA
Thermal Resolution240x240 pixels (with TISR)
Temperaturni opseg-68°F to 1022°F (approximately -55°C to 550°C)
Vrsta baterije12V litijum-jonska (uključena)
Kapacitet baterije1500 mAh (5.55 vat sati)
Vrijeme radaDo 7 sati
Težina artikla599 g
Dimenzije paketa24.41 x 15.09 x 6.71 cm
Funkcije multimetraVoltage (AC/DC), Current, Resistance, Continuity, Diode Test
Uključene komponenteThermal Imaging Camera with Multimeter, Test Leads, USB Cable, Macro Lens, Carrying Case, Manual
Zemlja porijeklaKina

10. Garancija i podrška

For warranty information and technical support, please refer to the warranty card included with your product or visit the official Hcalory webSačuvajte račun kao dokaz o kupovini za reklamacije u slučaju reklamacije.

In case of issues not covered in the troubleshooting section, or for service inquiries, please contact Hcalory customer support.

Povezani dokumenti - TS-M

Preview Uputstvo za upotrebu upravljačke ploče 12V električnog klima uređaja
Detaljna uputstva i tehničke specifikacije za kontrolnu ploču Hcalory 12V električnog klima uređaja, koje obuhvataju električne parametre, načine rada, funkcije dugmadi i indikacije grešaka.
Preview Uputstvo za upotrebu Hcalory dizel klima-grijača za automobil
Uputstvo za upotrebu za Hcalory dizelski zračni grijač za automobile, koje pruža uputstva o funkciji, instalaciji, sigurnosti, radu i rješavanju problema.
Preview Uputstvo za upotrebu Hcalory dizel klima-grijača za automobil
Uputstvo za upotrebu za Hcalory dizelski zračni grijač za automobile, koje obuhvata instalaciju, rad, sigurnosne smjernice i kodove grešaka za optimalnu upotrebu u vozilima i drugim okruženjima.
Preview Upute za upotrebu Hcalory automobilskog hladnjaka
Ovaj dokument pruža sveobuhvatna uputstva za upotrebu Hcalory auto frižidera, koja obuhvataju karakteristike, sigurnosne mjere predostrožnosti, osnovni rad, održavanje, rješavanje problema i tehničke specifikacije. Naučite kako da efikasno koristite i održavate svoj Hcalory auto frižider.
Preview Hcalory Diesel Standheizung Benutzerhandbuch und Installationsanleitung
Umfassende Anleitung für Hcalory Dieselstandheizungen, die Installation, Bedienung, Fehlerbehebung und App-Steuerung abdeckt. Enthält Sicherheitshinweise und technische Spezifikationen für Fahrzeug- und Freizeitanwendungen.
Preview Hcalory SS2 Diesel Air parking grijač za automobile korisnički priručnik
Uputstvo za upotrebu za Hcalory dizelski zračni grijač za automobile (Model SS2). Saznajte više o njegovim karakteristikama, radu, instalaciji i rješavanju problema za efikasno grijanje vozila i kabine.