TURBRO Greenland-12K115

TURBRO Greenland 12,000 BTU Ductless Mini Split Inverter AC with Heat Pump User Manual

Model: Greenland-12K115

1. Uvod

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your TURBRO Greenland 12,000 BTU Ductless Mini Split Inverter AC with Heat Pump. Please read this manual thoroughly before installation and use, and retain it for future reference.

Ključne karakteristike:

2. Šta se nalazi u kutiji

Your TURBRO Greenland Mini Split system is typically delivered in two separate boxes. Please verify all packages upon delivery to ensure all components are received before scheduling installation or beginning the installation process.

TURBRO Greenland Mini Split Indoor and Outdoor Units with Remote and App Interface

Figure 1: TURBRO Greenland Mini Split system components.

Box One (Indoor Unit & Accessories):

Box Two (Outdoor Unit & Installation Kit):

3. Podešavanje i instalacija

The TURBRO Greenland Mini Split AC is designed for easy installation with a step-by-step guide and numbered wiring diagram. However, professional installation is recommended to ensure optimal performance and safety.

Video 1: TURBRO Greenland Ductless Mini Split AC Installation Guide. This video provides a visual walkthrough of the installation process.

3.1 Instalacija unutrašnje jedinice

  1. Mounting Plate Placement: Use the provided cardboard template to mark the position for the indoor unit's mounting plate on the wall. Ensure adequate clearance: approximately 8 inches from the ceiling and 14 inches from adjacent walls. Use a level to ensure proper alignment.
  2. Bušenje rupa: Drill pilot holes for the mounting plate screws. For brick or concrete walls, use appropriate masonry drill bits and anchors. For drywall, locate studs or use heavy-duty drywall anchors rated for the unit's weight.
  3. Sigurna montažna ploča: Attach the mounting plate securely to the wall using the appropriate screws.
  4. Drill Conduit Hole: Drill a large hole (typically 2.5-3 inches in diameter) through the wall for the refrigerant lines, drain hose, and electrical cables. Ensure this hole is angled slightly downwards towards the exterior to facilitate drainage.
  5. Electrical Wiring (Indoor Unit): Open the front panel of the indoor unit. Locate the electrical terminal block. Connect the power wires from the outdoor unit to the corresponding terminals (L, N, 1, 2, 3, Ground) as indicated in the wiring diagram. Secure the wires with the cable clamp.
  6. Wrap Lines: Bundle the refrigerant lines, electrical cable, and drain hose together using insulation tape. This protects them and facilitates passage through the wall.
  7. Montiranje unutrašnje jedinice: Carefully feed the bundled lines through the wall hole. Lift the indoor unit and hook it onto the top of the mounting plate, then gently push the bottom until it snaps into place. Ensure the unit is level and securely attached.

3.2 Postavljanje vanjske jedinice

  1. Odabir lokacije: Choose a suitable, level location for the outdoor unit. Ensure at least 12 inches of clearance from the back of the unit to any wall and 20 inches on either side for proper airflow and maintenance.
  2. Install Rubber Feet: Attach the provided rubber feet to the base of the outdoor unit. These help reduce vibration and noise.
  3. Electrical Wiring (Outdoor Unit): Open the wiring cover on the outdoor unit. Connect the electrical wires from the indoor unit and the main power supply to the corresponding terminals (L, N, 1, 2, 3, Ground) as per the wiring diagram. Use liquid-tight conduit for the main power supply for safety and weather protection.
  4. Spojite rashladne vodove: Carefully bend the pre-charged refrigerant lines from the indoor unit to align with the outdoor unit's service ports. Remove protective caps and hand-tighten the flare nuts. Use two wrenches to tighten them to the specified torque.
  5. Spojite odvodno crijevo: Connect the outdoor unit's drain hose to the designated port.

3.3 Puštanje sistema u rad

  1. Vacuum the System: Connect a vacuum pump and gauge set to the low-pressure service port. Run the vacuum pump for at least 15 minutes to remove air and moisture from the refrigerant lines. Close the low-pressure port and monitor the gauge for at least 15 minutes to ensure no leaks are present (the reading should remain at -0.1 MPa).
  2. Release Refrigerant: If the system holds a vacuum, release a small amount of refrigerant into the lines for a leak check. Open the low-pressure valve for 5 seconds, then close it. Apply soapy water to all connections; if bubbles appear, there is a leak that needs to be addressed.
  3. Fully Open Valves: If no leaks are detected, fully open both the low and high-pressure valves to release the refrigerant into the system. Replace all protective caps.
  4. Uključeno: Turn on the dedicated 20-amp circuit breaker in your electrical panel. Your AC unit is now ready for operation.

4. Uputstvo za upotrebu

Your TURBRO Greenland Mini Split offers various operating modes and convenient control options.

4.1 Opcije kontrole

4.2 Načini rada

5. Održavanje

Redovno održavanje osigurava optimalne performanse i dugotrajnost vašeg uređaja.

5.1 Čišćenje filtera

The indoor unit's air filters are easily accessible for cleaning:

  1. Pažljivo otvorite prednju ploču unutrašnje jedinice.
  2. Uklonite filtere za vazduh.
  3. Clean the filters using a vacuum cleaner or by washing them with lukewarm water.
  4. Pustite da se filteri potpuno osuše prije ponovnog umetanja.
  5. Čvrsto zatvorite prednju ploču.

6. Otkrivanje problema

If you encounter issues with your unit, refer to the following common troubleshooting steps. For persistent problems, contact customer support.

7. Specifikacije

FeatureDetalj
BrandTURBRO
ModelGreenland-12K115
Kapacitet hlađenja12,000 BTU
Kapacitet grijanja12,000 BTU
Područje pokrivenostiDo 750 kvadratnih stopa
SEER2 ocjena23
Voltage115V
Wattage920W
Nivo buke (min)27 decibela
Rashladno sredstvoR454B
Posebne karakteristikeDehumidifier, Fast Cooling, Heating & Cooling, Inverter Compressor, WiFi Enabled
Energetski certifikatCertifikat Energy Star
Dimenzije unutrašnje jedinice36.2"W x 12.1"H x 7.7"D (approximate, inferred from image)
Dimenzije vanjske jedinice28.7"W x 21.7"H x 12.0"D (approximate, inferred from image)

8. Jamstvo i podrška

8.1 Informacije o garanciji

The TURBRO Greenland Mini Split Inverter AC comes with a 24-month warranty. Please refer to the full warranty details in the included User Manual for terms and conditions.

8.2 Korisnička podrška

For technical assistance, troubleshooting, or warranty claims, please contact TURBRO Customer Support. Contact information can be found in your User Manual or on the official TURBRO website.