1. Uvod
The ZEBRONICS MLS755 is a Line Interactive Uninterruptible Power Supply (UPS) system designed to provide reliable power backup and protection for various electronic devices. This UPS is specifically engineered to support micro-load applications such as WiFi routers, surveillance systems, PoE switches, smart home hubs, VoIP phones, and small NAS devices. It features advanced microcontroller-based control, a wide input voltage range, and a 3-tier battery management system to ensure stable performance and extended battery life.
2. Sigurnosna uputstva
Please read and follow these safety instructions carefully before installing or operating the UPS. Retain this manual for future reference.
- Ne otvarajte UPS uređajasing. Unutra nema dijelova koje korisnik može sam servisirati. Za sve servisne radove obratite se kvalifikovanom servisnom osoblju.
- Do not install the UPS in direct sunlight, near heat sources, or in environments with excessive dust, humidity, or corrosive substances.
- Ensure proper ventilation around the UPS. Do not block ventilation openings.
- Connect the UPS to a grounded AC power outlet only.
- Do not connect appliances that could overload the UPS, such as laser printers or heaters.
- In case of emergency, press the power button to turn off the UPS and disconnect it from the AC power supply.
3. Sadržaj paketa
Provjerite da li su sve stavke prisutne u paketu:
- ZEBRONICS MLS755 UPS Unit
- Uputstvo za upotrebu
- Power Cable (if included)
4. Proizvod je gotovview
The ZEBRONICS MLS755 UPS provides essential power protection and backup. Familiarize yourself with its components.
Prednja ploča

This image displays the front of the ZEBRONICS MLS755 UPS unit. It features a power button centrally located, surrounded by a red indicator light. Above the power button are three smaller indicator lights: red, yellow, and green, which signify different operational statuses. The Zebronics logo is visible at the bottom front.
- Dugme za napajanje: Koristi se za uključivanje ili isključivanje UPS-a.
- LED indikatori: Display the operational status of the UPS (e.g., AC mode, battery mode, fault, overload).
Rear Panel and Connectivity

This image shows the rear panel of the ZEBRONICS MLS755 UPS, highlighting its connectivity ports and a label with key specifications. The specifications listed include Nominal Voltage (220-240 VAC), Voltage Range (140-300 VAC), Frequency (50/60 Hz), Plug Type (3 Pin Plug), and Input Protection (Internal Fuse). The rear panel features multiple output sockets for connecting devices and an input power cord.
- AC ulaz: Povezuje UPS na glavni izvor napajanja.
- Izlazne utičnice: Provide power backup and surge protection for connected devices.
Vizualizacija ključnih karakteristika

This image illustrates the ZEBRONICS MLS755 UPS in an office setting, with a computer monitor and keyboard visible. The text overlay highlights "LED & Audible Alarms," indicating that the UPS provides visual and sound notifications for status changes or issues.

This image depicts the ZEBRONICS MLS755 UPS with two large green arrows forming a circular motion around it, symbolizing its "Auto restart while AC is recovering" feature. This indicates the UPS automatically resumes operation when main power is restored.

This image shows the ZEBRONICS MLS755 UPS with a graphic representation of electrical energy, illustrating the "Automatic Voltage Regulation (AVR)" feature. This function ensures a stable output voltage to connected devices, protecting them from power fluctuations.

This image presents a grid of nine blue squares, each highlighting a key feature of the ZEBRONICS MLS755 UPS. These features include: Line Interactive UPS, Micro-controller Based, Sleep Mode Charging, Cold Start, Generator Compatible, Boost & Buck AVR, Double Boost, Overload Protection, and Simulated Sine Wave.
Dimenzije proizvoda

This image provides a dimensional view of the ZEBRONICS MLS755 UPS. The measurements indicated are 14.2 cm (height), 28 cm (depth), and 10.1 cm (width). These dimensions help users understand the physical size of the unit for placement considerations.
5. Podešavanje
Follow these steps for initial setup of your UPS:
- Raspakivanje: Pažljivo izvadite UPS iz ambalaže. Pregledajte da li ima oštećenja prilikom transporta.
- plasman: Place the UPS on a flat, stable surface in a well-ventilated area, away from direct sunlight, heat, and moisture. Ensure adequate space around the unit for airflow.
- Početno punjenje: Connect the UPS to a standard grounded AC power outlet. Allow the UPS to charge for at least 6-8 hours before connecting any devices to ensure optimal battery performance. The UPS will charge whether it is turned on or off.
- Povezivanje uređaja: After initial charging, connect your devices (e.g., WiFi router, desktop PC, monitor) to the output sockets on the rear panel of the UPS. Ensure the total power consumption of connected devices does not exceed the UPS's capacity (600VA / 360W).
- Uključeno: Press the power button on the front panel to turn on the UPS. The LED indicators will illuminate to show its status.
6. Uputstvo za upotrebu
Understanding the operation of your ZEBRONICS MLS755 UPS.
Uključivanje/isključivanje
- Uključiti: Press and hold the power button for approximately 2 seconds until the UPS beeps and the indicators light up.
- Ugasiti: Press and hold the power button for approximately 2 seconds until the UPS beeps and the indicators turn off.
LED Indicators and Audible Alarms
The UPS provides visual and audible alerts to communicate its status:
- Zelena LED: Indicates AC mode (normal operation, power supplied from utility).
- Žuta LED dioda: Indicates battery mode (power supplied from UPS battery during an outagi).
- Crveni LED: Indicates a fault, overload, or low battery condition. Refer to the troubleshooting section for details.
- Zvučni alarmi: Various beeping patterns indicate different events such as power failure, low battery, or overload.
Automatic Voltage Regulacija (AVR)
The MLS755 features AVR with double boost and buck functionality. This automatically corrects minor power fluctuations (sags and surges) without switching to battery power, thereby extending battery life and providing stable power to your devices.
Funkcija automatskog ponovnog pokretanja
When AC power is restored after a power outage, the UPS will automatically restart and resume normal operation, ensuring continuous protection for your connected devices.
Micro Load Support
This UPS is optimized for micro-load devices, ensuring that even low-power equipment like WiFi routers receive stable and continuous power during outages. The ZEB Micro Load Sense System ensures consistent performance across a wide input voltage range.
7. Održavanje
Proper maintenance ensures the longevity and optimal performance of your UPS.
- Upravljanje baterijom: The MLS755 incorporates an advanced 3-tier battery management system that optimizes charging and discharging cycles, extending battery life by over 30%.
- Redovno punjenje: To maintain battery health, keep the UPS connected to AC power at all times. If the UPS is stored for an extended period, recharge it every three months for at least 6-8 hours.
- čišćenje: Povremeno čistite vanjski dio UPS-a mekom, suhom krpom. Ne koristite tekuća ili aerosolna sredstva za čišćenje. Osigurajte da su ventilacijski otvori bez prašine i ostataka.
- Zamjena baterije: Batteries are consumable items. When the battery capacity significantly decreases, it may need replacement. Contact authorized service personnel for battery replacement.
8. Otkrivanje problema
Ako naiđete na probleme sa svojim UPS-om, pogledajte sljedeće uobičajene probleme i rješenja:
| Problem | Mogući uzrok | Rješenje |
|---|---|---|
| UPS se ne uključuje | No AC input; Low battery; Power button not pressed correctly | Check AC power connection; Allow UPS to charge; Press and hold power button for 2 seconds |
| UPS beeps continuously in AC mode | Overload; Internal fault | Reduce connected load; Contact service center |
| Kratko vrijeme sigurnosne kopije | Battery not fully charged; Battery end-of-life | Charge UPS for 6-8 hours; Consider battery replacement |
| UPS ne obezbjeđuje napajanje u režimu rada na baterije | Battery deeply discharged; Internal fault | Allow UPS to charge; Contact service center |
If the problem persists after attempting these solutions, please contact ZEBRONICS customer support.
9. Specifikacije
Detailed technical specifications for the ZEBRONICS MLS755 UPS System:
| Feature | Specifikacija |
|---|---|
| Model | MLS755 |
| Kapacitet | 600VA/360W |
| Tip | Line Interactive UPS |
| Ulazni voltage domet | 140-300 VAC |
| Nominal Voltage | 220-240 VAC |
| Frekvencija | 50/60 Hz (Auto Sensing) |
| Izlazni talasni oblik | Simulirani sinusni val |
| Vrsta baterije | Sealed Lead Acid, Maintenance Free |
| Average Battery Life (Backup) | Up to 225 minutes (under micro-load conditions) |
| Vrijeme punjenja | 6-8 sati do 90% kapaciteta |
| Dimenzije (DxŠxV) | 14.2 x 32.6 x 21.3 cm |
| Težina artikla | 3.82 kg |
| Boja | Crna |
| Karakteristike | Microcontroller Based, Micro Load Sense, 3-Tier Battery Management, AVR, Double Boost, Auto Restart, Overload Protection, Generator Compatible |
10. Garancija i podrška
ZEBRONICS products are manufactured under strict quality standards. This product is covered by a limited warranty from the date of purchase. Please retain your purchase receipt as proof of purchase.
For warranty claims, technical support, or service inquiries, please contact ZEBRONICS customer service. You can find contact information on the official ZEBRONICS webweb-mjestu ili putem vašeg lokalnog prodavača.
Proizvođač: Zebronics India Private Limited
Adresa: Br. 13/7, Smith Road, Royapettah, Chennai - 600 002