1. Uvod
This manual provides essential information for the installation, operation, and maintenance of your ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System. This system is designed to provide efficient heating and cooling for residential and light commercial applications. Please read this manual thoroughly before attempting any installation or operation to ensure proper function and safety.
2. Sigurnosne informacije
Always prioritize safety. Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death. Consult a qualified installer, service agency, or the gas supplier for information or assistance. The information contained in this manual is intended for use by qualified service personnel only.
- električna sigurnost: Ensure the power supply is disconnected before performing any service or maintenance. All electrical wiring must comply with local and national electrical codes.
- Rukovanje rashladnim sredstvom: This system uses R-454B refrigerant. Only certified technicians should handle refrigerants.
- Instalacija: Installation must be performed by a licensed HVAC professional.
- Lična zaštitna oprema: Always wear appropriate personal protective equipment (PPE) such as gloves and safety glasses during installation and maintenance.
3. Ključne karakteristike
- Tehnologija invertera: Pruža preciznu kontrolu temperature, smanjenu potrošnju energije i tiši rad.
- Visoka efikasnost: 18.8 SEER2 and 9.7 HSPF2 ratings for energy savings.
- Široki radni opseg: Reliable performance from -13°F to 122°F.
- tihi rad: Indoor noise levels as low as 44 dBA, outdoor unit at 60 dBA.
- Izdržljive komponente: Rotary compressor, aluminum coil, and fiberglass-free insulation.
- Ekološki prihvatljivo rashladno sredstvo: Utilizes R-454B refrigerant.
- Fleksibilna instalacija: Supports horizontal and vertical air handler installation.
- Pametne kontrole: Compatible with wired controllers, WiFi, and third-party thermostats.
- Integrated Back-up Heat: Includes a 10kW back-up heat kit for supplemental heating.
4. Components Overview
The ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System includes the following main components:
- Outdoor Condensing Unit (Heat Pump)
- Indoor Air Handler Unit
- 10kW Back-up Heat Kit
- 30' Line Set
- Gauge Electrical Whip
- 60A Non-Fused Disconnect Switch
- WiFi termostat
- Zaštita od prenapona
- CPS Charging Adapter
- Zidni rukav

Slika 1: Gotovoview of the ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System, showing the outdoor unit, indoor air handler, 10kW back-up heat kit, thermostat, line set, and various installation accessories.
5. Postavljanje i instalacija
Installation of this ACiQ heat pump system requires specialized knowledge and tools. It must be performed by a qualified and licensed HVAC technician to ensure safety, compliance with local codes, and optimal performance. Refer to the detailed installation manual provided with the product for specific instructions.
5.1 Provjere prije instalacije
- Verify that the electrical supply matches the unit's requirements (Indoor: 115/208/230V, 60Hz, 1Ph; Outdoor: 208/230V, 60Hz, 1Ph).
- Osigurajte dovoljno prostora za unutrašnju i vanjsku jedinicu, omogućavajući pravilan protok zraka i pristup za održavanje.
- Confirm that the maximum piping length (164 ft / 50m) and height difference (82 ft / 25m) are not exceeded.
5.2 Air Handler Installation
The indoor air handler unit is designed for flexible installation, supporting upflow, downflow, and horizontal configurations to suit various space requirements.

Slika 2: Diagram illustrating the multi-positional capabilities of the indoor air handler unit, showing options for upflow, downflow, and horizontal installation.
5.3 Postavljanje vanjske jedinice
Consider the outdoor unit's dimensions and required clearances for optimal performance and maintenance. The unit features a compact design compared to traditional systems.

Slika 3: Graphic comparing the smaller footprint of the ACiQ outdoor unit (20 inches clearance) versus a traditional unit (36 inches clearance), highlighting its high efficiency and self-cleaning features.
6. Uputstvo za upotrebu
Your ACiQ heat pump system offers advanced control options for comfortable and efficient operation.
6.1 Osnovni načini rada
- Način hlađenja: Provides cooling with a capacity of 31,000 BTU/hr. Operates efficiently from -13°F to 122°F ambient temperatures.
- Način grijanja: Provides heating with a capacity of 30,000 BTU/hr at 47°F. Reliable warmth down to -13°F. The 10kW back-up heat kit provides supplemental heat when needed.
- Način rada ventilatora: Cirkulira zrak bez zagrijavanja ili hlađenja.
- Automatski režim: Automatski se prebacuje između grijanja i hlađenja kako bi se održala zadana temperatura.

Slika 4: The ACiQ outdoor unit installed on a patio, demonstrating its ability to operate effectively in extreme heat conditions, up to 122°F.

Slika 5: The ACiQ outdoor unit partially covered in snow, illustrating its capability to operate in extreme cold temperatures, down to -13°F.
6.2 Smart Controls
The system can be controlled via the included wired thermostat, WiFi-enabled app, or compatible third-party thermostats. The WiFi app allows for remote control and monitoring of your system.

Slika 6: Image showing the ACiQ Smart Home mobile application interface on a smartphone alongside a wired thermostat, demonstrating the system's smart control capabilities for climate management.
7. Održavanje
Regular maintenance ensures the longevity and efficiency of your ACiQ heat pump system. Always disconnect power before performing any maintenance.
- Zamjena filtera zraka: Check and replace air filters in the indoor air handler every 1-3 months, or more frequently if needed. Dirty filters restrict airflow and reduce efficiency.
- Čišćenje vanjske jedinice: Keep the outdoor unit free from debris, leaves, and dirt. Periodically clean the coils with a soft brush or water hose (ensure power is off).
- Sistem odvodnje: Ensure the condensate drain line is clear and free of blockages to prevent water overflow.
- Stručni pregled: Schedule annual inspections and maintenance by a qualified HVAC technician.
8. Otkrivanje problema
This section provides solutions for common issues. For complex problems, contact a qualified HVAC technician.
- Nema napajanja: Check circuit breakers and ensure the disconnect switch is in the ON position.
- Insufficient Heating/Cooling: Verify thermostat settings, check air filters for blockage, and ensure outdoor unit is not obstructed.
- Neobični zvukovi: Minor operational noises are normal. Loud or unusual noises may indicate a problem requiring professional inspection.
- Curenje vode: Check condensate drain line for blockages.
9. Specifikacije

Slika 7: Image displaying the dimensions of both the indoor air handler unit (49.02" H x 21.02" W x 21.02" D) and the outdoor condensing unit (35.04" H x 37.24" W x 16.14" D).

Slika 8: Chart detailing the cooling capacity of the ACiQ system at various outdoor temperatures: 86°F (118% capacity), 95°F (113% capacity), 110°F (99% capacity), and 122°F (48% capacity).

Slika 9: Chart detailing the heating capacity of the ACiQ system at various outdoor temperatures: -22°F (N/A), -13°F (41% capacity), 0°F (57% capacity), 17°F (70% capacity), and 32°F (73% capacity).
| Feature | Detalj |
|---|---|
| Kapacitet hlađenja | 31,000 BTU/h |
| Kapacitet grijanja | 30,000 BTU/hr (at 47°F) |
| SEER2 ocjena | 18.8 |
| HSPF2 ocjena | 9.7 |
| Vrsta rashladnog sredstva | R-454B |
| Napajanje unutrašnje jedinice | 115/208/230V, 60Hz, 1Ph |
| Outdoor Unit Power Supply | 208/230V, 60Hz, 1 faza |
| Maksimalna dužina cijevi | 164 stopa (50m) |
| Maksimalna visinska razlika | 82 stopa (25m) |
| Indoor Unit Dimensions (W × D × H) | 21.02" × 21.02" × 49.02" |
| Outdoor Unit Dimensions (W × D × H) | 37.24" × 16.14" × 31.89" |
| Neto težina unutrašnje jedinice | 128.97 lbs |
| Neto težina vanjske jedinice | 164.02 lbs |
10. Garancija i podrška
ACiQ offers a comprehensive warranty for this heat pump system:
- Garancija na dijelove: 7 godine
- Garancija na kompresor: 12 godine
These warranty terms are valid when the system is installed by a certified technician and registered online with the manufacturer. For technical support, service inquiries, or warranty claims, please refer to the contact information provided in your product packaging or visit the official ACiQ website.