This manual provides essential information for the installation, operation, and maintenance of your ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System. This system is designed to provide efficient heating and cooling for residential and light commercial applications. Please read this manual thoroughly before attempting any installation or operation to ensure proper function and safety.

2. Sigurnosne informacije

Always prioritize safety. Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death. Consult a qualified installer, service agency, or the gas supplier for information or assistance. The information contained in this manual is intended for use by qualified service personnel only.

  • električna sigurnost: Ensure the power supply is disconnected before performing any service or maintenance. All electrical wiring must comply with local and national electrical codes.
  • Rukovanje rashladnim sredstvom: This system uses R-454B refrigerant. Only certified technicians should handle refrigerants.
  • Instalacija: Installation must be performed by a licensed HVAC professional.
  • Lična zaštitna oprema: Always wear appropriate personal protective equipment (PPE) such as gloves and safety glasses during installation and maintenance.

3. Ključne karakteristike

  • Tehnologija invertera: Pruža preciznu kontrolu temperature, smanjenu potrošnju energije i tiši rad.
  • Visoka efikasnost: 18.8 SEER2 and 9.7 HSPF2 ratings for energy savings.
  • Široki radni opseg: Reliable performance from -13°F to 122°F.
  • tihi rad: Indoor noise levels as low as 44 dBA, outdoor unit at 60 dBA.
  • Izdržljive komponente: Rotary compressor, aluminum coil, and fiberglass-free insulation.
  • Ekološki prihvatljivo rashladno sredstvo: Utilizes R-454B refrigerant.
  • Fleksibilna instalacija: Supports horizontal and vertical air handler installation.
  • Pametne kontrole: Compatible with wired controllers, WiFi, and third-party thermostats.
  • Integrated Back-up Heat: Includes a 10kW back-up heat kit for supplemental heating.

4. Components Overview

The ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System includes the following main components:

  • Outdoor Condensing Unit (Heat Pump)
  • Indoor Air Handler Unit
  • 10kW Back-up Heat Kit
  • 30' Line Set
  • Gauge Electrical Whip
  • 60A Non-Fused Disconnect Switch
  • WiFi termostat
  • Zaštita od prenapona
  • CPS Charging Adapter
  • Zidni rukav
ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System components

Slika 1: Gotovoview of the ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System, showing the outdoor unit, indoor air handler, 10kW back-up heat kit, thermostat, line set, and various installation accessories.

5. Postavljanje i instalacija

Installation of this ACiQ heat pump system requires specialized knowledge and tools. It must be performed by a qualified and licensed HVAC technician to ensure safety, compliance with local codes, and optimal performance. Refer to the detailed installation manual provided with the product for specific instructions.

5.1 Provjere prije instalacije

  • Verify that the electrical supply matches the unit's requirements (Indoor: 115/208/230V, 60Hz, 1Ph; Outdoor: 208/230V, 60Hz, 1Ph).
  • Osigurajte dovoljno prostora za unutrašnju i vanjsku jedinicu, omogućavajući pravilan protok zraka i pristup za održavanje.
  • Confirm that the maximum piping length (164 ft / 50m) and height difference (82 ft / 25m) are not exceeded.

5.2 Air Handler Installation

The indoor air handler unit is designed for flexible installation, supporting upflow, downflow, and horizontal configurations to suit various space requirements.

Multi-Positional Air Handler Unit installation options

Slika 2: Diagram illustrating the multi-positional capabilities of the indoor air handler unit, showing options for upflow, downflow, and horizontal installation.

5.3 Postavljanje vanjske jedinice

Consider the outdoor unit's dimensions and required clearances for optimal performance and maintenance. The unit features a compact design compared to traditional systems.

Outdoor unit size comparison with traditional units

Slika 3: Graphic comparing the smaller footprint of the ACiQ outdoor unit (20 inches clearance) versus a traditional unit (36 inches clearance), highlighting its high efficiency and self-cleaning features.

6. Uputstvo za upotrebu

Your ACiQ heat pump system offers advanced control options for comfortable and efficient operation.

6.1 Osnovni načini rada

  • Način hlađenja: Provides cooling with a capacity of 31,000 BTU/hr. Operates efficiently from -13°F to 122°F ambient temperatures.
  • Način grijanja: Provides heating with a capacity of 30,000 BTU/hr at 47°F. Reliable warmth down to -13°F. The 10kW back-up heat kit provides supplemental heat when needed.
  • Način rada ventilatora: Cirkulira zrak bez zagrijavanja ili hlađenja.
  • Automatski režim: Automatski se prebacuje između grijanja i hlađenja kako bi se održala zadana temperatura.
ACiQ outdoor unit operating in extreme heat

Slika 4: The ACiQ outdoor unit installed on a patio, demonstrating its ability to operate effectively in extreme heat conditions, up to 122°F.

ACiQ outdoor unit operating in extreme cold

Slika 5: The ACiQ outdoor unit partially covered in snow, illustrating its capability to operate in extreme cold temperatures, down to -13°F.

6.2 Smart Controls

The system can be controlled via the included wired thermostat, WiFi-enabled app, or compatible third-party thermostats. The WiFi app allows for remote control and monitoring of your system.

ACiQ Smart Home app and wired thermostat

Slika 6: Image showing the ACiQ Smart Home mobile application interface on a smartphone alongside a wired thermostat, demonstrating the system's smart control capabilities for climate management.

7. Održavanje

Regular maintenance ensures the longevity and efficiency of your ACiQ heat pump system. Always disconnect power before performing any maintenance.

  • Zamjena filtera zraka: Check and replace air filters in the indoor air handler every 1-3 months, or more frequently if needed. Dirty filters restrict airflow and reduce efficiency.
  • Čišćenje vanjske jedinice: Keep the outdoor unit free from debris, leaves, and dirt. Periodically clean the coils with a soft brush or water hose (ensure power is off).
  • Sistem odvodnje: Ensure the condensate drain line is clear and free of blockages to prevent water overflow.
  • Stručni pregled: Schedule annual inspections and maintenance by a qualified HVAC technician.

8. Otkrivanje problema

This section provides solutions for common issues. For complex problems, contact a qualified HVAC technician.

  • Nema napajanja: Check circuit breakers and ensure the disconnect switch is in the ON position.
  • Insufficient Heating/Cooling: Verify thermostat settings, check air filters for blockage, and ensure outdoor unit is not obstructed.
  • Neobični zvukovi: Minor operational noises are normal. Loud or unusual noises may indicate a problem requiring professional inspection.
  • Curenje vode: Check condensate drain line for blockages.

9. Specifikacije

Dimensions of ACiQ indoor and outdoor units

Slika 7: Image displaying the dimensions of both the indoor air handler unit (49.02" H x 21.02" W x 21.02" D) and the outdoor condensing unit (35.04" H x 37.24" W x 16.14" D).

Cooling capacity chart for ACiQ heat pump

Slika 8: Chart detailing the cooling capacity of the ACiQ system at various outdoor temperatures: 86°F (118% capacity), 95°F (113% capacity), 110°F (99% capacity), and 122°F (48% capacity).

Heating capacity chart for ACiQ heat pump

Slika 9: Chart detailing the heating capacity of the ACiQ system at various outdoor temperatures: -22°F (N/A), -13°F (41% capacity), 0°F (57% capacity), 17°F (70% capacity), and 32°F (73% capacity).

FeatureDetalj
Kapacitet hlađenja31,000 BTU/h
Kapacitet grijanja30,000 BTU/hr (at 47°F)
SEER2 ocjena18.8
HSPF2 ocjena9.7
Vrsta rashladnog sredstvaR-454B
Napajanje unutrašnje jedinice115/208/230V, 60Hz, 1Ph
Outdoor Unit Power Supply208/230V, 60Hz, 1 faza
Maksimalna dužina cijevi164 stopa (50m)
Maksimalna visinska razlika82 stopa (25m)
Indoor Unit Dimensions (W × D × H)21.02" × 21.02" × 49.02"
Outdoor Unit Dimensions (W × D × H)37.24" × 16.14" × 31.89"
Neto težina unutrašnje jedinice128.97 lbs
Neto težina vanjske jedinice164.02 lbs

10. Garancija i podrška

ACiQ offers a comprehensive warranty for this heat pump system:

  • Garancija na dijelove: 7 godine
  • Garancija na kompresor: 12 godine

These warranty terms are valid when the system is installed by a certified technician and registered online with the manufacturer. For technical support, service inquiries, or warranty claims, please refer to the contact information provided in your product packaging or visit the official ACiQ website.

Povezani dokumenti - B0DHFF2DKL

Preview ACiQ 9K-24K Standardni sistemi grijanja s jednom zonom: Uputstvo za instalaciju i upotrebu
ACiQ 9K-24K Standardni priručnik za instalaciju i upotrebu jednozonskih sistema grijanja. Ovaj vodič detaljno opisuje instalaciju, rad, sigurnost i održavanje ACiQ klima uređaja, uključujući specifikacije modela i informacije o rashladnom sredstvu R454B.
Preview Uputstvo za instalaciju ACiQ centralnih inverterskih sistema
Sveobuhvatni priručnik za instalaciju ACiQ centralnih inverterskih klima uređaja i sistema toplotnih pumpi, koji detaljno opisuje sigurnosne mjere, cjevovode rashladnog sredstva, instalaciju vanjske jedinice, ožičenje, specifikacije napajanja, odzračivanje i postupke probnog rada.
Preview ACiQ zidni klima uređaj i ekstremno toplinski jednozonski kondenzatorski uređaj - uputstvo za ugradnju i upotrebu
Ovaj priručnik pruža detaljne smjernice za instalaciju, rad i sigurnost za ACiQ zidne klima uređaje i ekstremno vruće jednozonske kondenzatore, koji pokrivaju modele od ACIQ-06W-HH-MD do ACIQ-24ZPL-HP230C.
Preview ACiQ Central Inverter Systems Uputstvo za instalaciju vanjske jedinice
Sveobuhvatni priručnik za instalaciju vanjskih jedinica ACiQ Central Inverter Systems, koji pokriva sigurnosne mjere opreza, cijevi za rashladno sredstvo, ožičenje, instalaciju jedinice i postupke testiranja za modele kao što su ACiQ-18-AC, ACiQ-24-AC, ACiQ-18-EHPB i druge.
Preview ACiQ sistem toplotne pumpe sljedeće generacije s kanalima: Kratki vodič za ožičenje termostata
Ovaj vodič pruža osnovne informacije za povezivanje i ožičenje termostata na ACiQ Next Gen sistem toplotne pumpe sa kanalima. Detaljno opisuje preporučene i alternativne opcije povezivanja, uključujući postavke DIP prekidača i konfiguracije terminalnih blokova za različite tipove termostata.
Preview ACiQ Essentials Mini-Split Air Handler & Condenser Installation and Owner's Manual
Comprehensive installation and owner's manual for ACiQ Essentials Mini-Split Air Handler and Condenser systems, covering safety precautions, parts identification, remote control operation, installation procedures, test runs, maintenance, and troubleshooting for various models. The manual also includes critical information regarding the servicing of systems using flammable refrigerant R454B, emphasizing safety protocols and regulatory compliance. It is designed for professional installers and end-users to ensure safe and efficient operation of ACiQ mini-split heat pump systems.