Goodman GLXS3BN3610CHPTA4230C3

Goodman 3 Ton 13.4 SEER2 R-32 AC System with Horizontal Coil User Manual

Models: GLXS3BN3610 Condenser & CHPTA4230C3 Coil

1. Uvod

This manual provides essential information for the safe and efficient operation of your Goodman 3 Ton 13.4 SEER2 R-32 AC Only System, comprising the GLXS3BN3610 Air Conditioner Condenser and the CHPTA4230C3 Horizontal Coil. This system is designed to provide efficient cooling for your home. Please read this manual thoroughly before installation or operation.

2. Važne informacije o sigurnosti

WARNING: Installation and servicing of this equipment can be hazardous due to mechanical and electrical components. Only trained and qualified personnel should install, repair, or service HVAC equipment. Improper installation, adjustment, alteration, service, or maintenance can cause property damage, personal injury, or death.

This system utilizes R-32 refrigerant, which is mildly flammable. Proper handling and installation procedures are critical to ensure safety. A certified HVAC technician must perform all installation and service work.

3. Komponente sistema

Your Goodman AC system includes the following primary components:

Note: This is a partial system. A furnace or modular blower is required to complete the system and provide air circulation and heating capabilities (if applicable).

Goodman GLXS3BN3610 Condenser and CHPTA4230C3 Horizontal Coil

Figure 1: Goodman GLXS3BN3610 Condenser and CHPTA4230C3 Horizontal Coil

Goodman GLXS3BN3610 Condenser

Figure 2: Goodman GLXS3BN3610 Condenser Unit

Goodman CHPTA4230C3 Horizontal Coil

Figure 3: Goodman CHPTA4230C3 Horizontal Coil Unit

4. Podešavanje i instalacija

Installation of this HVAC system must be performed by a qualified, licensed HVAC professional. Incorrect installation can lead to system malfunction, safety hazards, and void the warranty.

4.1. Kompatibilnost sistema

This system is designed to be paired with a compatible furnace or modular blower. Ensure that the indoor coil (CHPTA4230C3) is correctly matched with your furnace's airflow configuration (horizontal for this coil).

Video 1: This video explains the importance of matching your condenser and coil for optimal system performance.

4.2. SEER2 Regulations

As of January 1, 2023, new SEER2 (Seasonal Energy Efficiency Ratio 2) regulations are in effect. This Goodman system has a 13.4 SEER2 rating. Please note that federal regulations specify minimum SEER2 ratings based on geographic region. This system does not comply with federal regulations for installation in the following states: AL, AR, AZ, CA, DE, FL, GA, KY, LA, MD, MS, NC, NM, NV, OK, SC, TN, TX, and VA.

Energy Guide Label for Goodman GLXS3BN3610A

Figure 4: Energy Guide label showing 13.40 SEER2 rating for the Goodman GLXS3BN3610A model.

US Map showing North and South HVAC regions

Figure 5: US Map indicating the North Region (blue) where 13.4 SEER2 is acceptable, and other regions (orange and green) with different minimum requirements.

Video 2: Ovaj video pruža pregledview of the SEER2 regulations that came into effect on January 1, 2023.

4.3. R-32 Refrigerant

This system uses R-32 refrigerant. R-32 is a more energy-efficient refrigerant with a lower global warming impact compared to older refrigerants. It is mildly flammable, requiring specific installation and servicing protocols. If this system is paired with a furnace, an R-32 leak detection system is required to ensure safe operation by turning off the furnace burner in case of a refrigerant leak.

Video 3: This video explains the new refrigerant regulations and the properties of R-32.

Video 4: This video clarifies facts versus fiction regarding R-32 refrigerant.

5. Uputstvo za upotrebu

Once installed by a qualified technician, your Goodman AC system will operate to provide cooling. The system is controlled via your home's thermostat. Set your desired temperature, and the system will cycle on and off to maintain it.

Video 5: This video explains different types of HVAC systems, including split systems like this one, and how they operate.

6. Održavanje

Regular maintenance is crucial for the longevity and efficiency of your AC system. It is recommended to have your system inspected and serviced by a qualified HVAC technician annually.

7. Otkrivanje problema

If you experience issues with your system, consider the following basic checks before contacting a service technician:

For any issues beyond basic troubleshooting, contact a qualified HVAC service technician. Do not attempt complex repairs yourself.

8. Specifikacije

FeatureSpecifikacija
BrandGoodman
Informacije o modeluGLXS3BN3610CHPTA4230C3
Model kondenzatoraGLXS3BN3610
Coil ModelCHPTA4230C3
Kapacitet3 tona
SEER2 ocjena13.4
Vrsta rashladnog sredstvaR-32
Vrsta instalacijeSplit sistem
Coil OrientationHorizontalno
Težina artikla246 funti (ukupno)
Posebna karakteristikaBrzo hlađenje

9. Informacije o garanciji

This Goodman system comes with a Ograničena garancija na dijelove 10 godina. To qualify for the full warranty, the system must be installed by a qualified installer and registered online within 60 days of installation. Online registration is not required in California.

For complete warranty details and terms, please refer to the official Goodman warranty documentation or contact customer support.

Goodman 10 Year Limited Warranty Shield

Slika 6: Goodmanov 10-godišnji ograničeni garantni štit.

10. Korisnička podrška

For technical assistance, warranty claims, or any questions regarding your Goodman HVAC system, please contact Superior Home Supplies customer support. Their contact information can typically be found on your purchase receipt or their official website.

Povezani dokumenti - GLXS3BN3610CHPTA4230C3

Preview Specifikacije proizvoda Goodman GPG13 paketne plinske/električne jedinice
Detaljne specifikacije proizvoda za Goodman GPG13 seriju jednofaznih, samostalnih pakiranih plinskih/električnih jedinica, koje obuhvataju karakteristike, detalje o ormariću, nomenklaturu, specifikacije, dimenzije, dijagrame ožičenja i pribor.
Preview Upute za ugradnju horizontalne dvosmjerne zavojnice | Goodman HVAC
Sveobuhvatni vodič za instalaciju Goodman horizontalnih dvosmjernih HVAC zavojnica. Obuhvata osnovna sigurnosna upozorenja, provjere prije instalacije, detalje primjene, pričvršćivanje prirubnice kanala, cijevi za odvod kondenzata, postupke vodova rashladnog sredstva, podešavanje protoka, čišćenje zavojnica i listu za provjeru pokretanja. Uključuje informacije o modelu IO-285M.
Preview Upute za ugradnju horizontalnog dvosmjernog grijača | Goodman, Daikin, Amana HVAC
Sveobuhvatni vodič za instalaciju horizontalnih dvosmjernih isparivača koje proizvodi Goodman Manufacturing Company, LP, za upotrebu sa Goodman, Daikin i Amana HVAC sistemima. Obuhvata osnovne sigurnosne mjere opreza, provjere prije instalacije, detalje primjene, pričvršćivanje prirubnica kanala, cijevi za odvod kondenzata, instalaciju rashladnog voda, podešavanja regulatora protoka i postupke čišćenja unutrašnjeg isparivača. Uključuje savjete za rješavanje problema i kontakt informacije.
Preview Specifikacije i karakteristike paketnog klima uređaja Goodman GPCH3
Sveobuhvatni vodič za paketne klima uređaje serije Goodman GPCH3, koji obuhvata standardne i karakteristike ormara, nomenklaturu, detaljne specifikacije proizvoda, proširene podatke o hlađenju i protoku zraka, električne informacije za komplete grijanja, dimenzije, dijagrame ožičenja i dostupnu dodatnu opremu. Dizajnirane za efikasnost i izdržljivost, ove jedinice su dostupne u težinama od 2 do 5 tona sa SEER2 ocjenom od 13.4.
Preview Upute za instalaciju Goodman horizontalne dvosmjerne zavojnice (IO-285G)
Comprehensive installation guide for Goodman Horizontal Two-Way Coils (Model IO-285G). Includes essential safety warnings, pre-installation checks, application details, ductwork and condensate drain setup, refrigerant line procedures, and special flowrator instructions for HVAC technicians.
Preview Upute za instalaciju Goodman horizontalne dvosmjerne zavojnice
Detailed installation instructions for Goodman Horizontal Two-Way Coils (P/N: IO-285B), covering safety warnings, shipping inspection, codes and regulations, replacement parts, pre-installation steps, application information, duct flange attachment, condensate drain piping, and refrigerant line procedures. Includes diagrams described in text.