UNI-T UPO1102

UNI-T UPO1102 100MHz 2-Channel Digital Oscilloscope Instruction Manual

Model: UPO1102

1. Uvod

This instruction manual provides essential information for the safe and effective use of the UNI-T UPO1102 100MHz 2-Channel Digital Oscilloscope. The UPO1102 is a versatile instrument designed for electronic and electrical measurements, featuring a 100MHz bandwidth, 1 GSa/s real-time sample rate, 56 Mpts memory depth, and a 7-inch display. It incorporates Ultra Phosphor technology for enhanced waveform display and analysis capabilities.

Molimo vas da pažljivo pročitate ovaj priručnik prije upotrebe uređaja kako biste osigurali pravilno funkcioniranje i spriječili oštećenja.

2. Sigurnosne informacije

Always observe the following safety precautions to avoid personal injury and prevent damage to the instrument or other connected devices.

3. Proizvod je gotovview

3.1 Prednja ploča

Front view of the UNI-T UPO1102 Digital Oscilloscope, showing the 7-inch display, control knobs, and input connectors.

Figure 3.1: Front Panel of UPO1102 Oscilloscope

The front panel features the main display, various control knobs and buttons for waveform adjustment, trigger settings, and menu navigation. Input channels CH1 and CH2 are located at the bottom right.

3.2 Zadnja ploča

Pozadi view of the UNI-T UPO1102 Digital Oscilloscope, showing the power input, USB ports, and ventilation.

Figure 3.2: Rear Panel of UPO1102 Oscilloscope

The rear panel includes the AC power input, USB ports for data transfer and printing, and ventilation grilles to ensure proper cooling during operation.

3.3 Dimenzije

Dimensions of the UNI-T UPO1102 Digital Oscilloscope, showing a width of 13.23 inches, height of 6.46 inches, and depth of 4.13 inches.

Figure 3.3: UPO1102 Oscilloscope Dimensions

The physical dimensions of the UPO1102 are approximately 13.23 inches (width) x 6.46 inches (height) x 4.13 inches (depth).

4. Podešavanje

4.1 Raspakivanje i pregled

Upon receiving your UPO1102 oscilloscope, carefully unpack all components and inspect them for any signs of damage. Retain the packaging for future transport or storage.

Standardna dodatna oprema:

4.2 Priključak za napajanje

  1. Ensure the oscilloscope is placed on a stable, level surface with adequate ventilation.
  2. Spojite priloženi kabel za napajanje na ulaz za izmjeničnu struju na stražnjoj ploči osciloskopa.
  3. Uključite drugi kraj kabla za napajanje u uzemljenu utičnicu za naizmjeničnu struju.
  4. Pritisnite dugme za napajanje na prednjoj ploči da biste uključili osciloskop.

4.3 Spajanje sonde i kompenzacija

Before taking measurements, it is crucial to compensate the probes to ensure accurate readings.

  1. Connect a probe to one of the input channels (CH1 or CH2) on the front panel.
  2. Connect the probe tip to the "Probe Comp" terminal and the ground clip to the ground terminal next to it.
  3. Pritisnite Auto button. The oscilloscope will automatically adjust the settings to display the compensation signal.
  4. Observe the square wave displayed on the screen. If the waveform is not a perfect square (over-compensated or under-compensated), adjust the trimmer on the probe body using a non-metallic tool until a flat-top square wave is achieved.
  5. Repeat for the second probe if using both channels.
Example of a square wave displayed on the oscilloscope screen during probe compensation.

Figure 4.1: Probe Compensation Waveform

A correctly compensated probe displays a clean square wave. Adjust the probe's trimmer if the waveform shows overshoot or undershoot.

5. Uputstvo za upotrebu

5.1 Osnovne kontrole

5.2 Akvizicija i prikaz talasnih oblika

The UPO1102 features a 7-inch display and Ultra Phosphor technology for clear waveform visualization, even with complex signals.

Oscilloscope display showing a complex waveform with varying intensity, demonstrating Ultra Phosphor technology.

Figure 5.1: Ultra Phosphor Display

Ultra Phosphor technology provides a gradient display, where brighter areas indicate more frequent occurrences of the waveform, helping to visualize signal anomalies and variations.

Oscilloscope display showing two overlaid waveforms, demonstrating multi-channel measurement.

Figure 5.2: Multi-Channel Waveform Display

The UPO1102 can display and analyze two channels simultaneously, allowing for comparison of different signals.

5.3 Funkcije mjerenja

5.4 Digital Decoding

The innovative hardware decoding feature allows for real-time decoding of serial bus protocols. With a deep storage of 56 Mpts, decoding speed is maintained at millisecond levels, preventing delays when viewing decoded data. This function does not affect the waveform refresh rate, maintaining the digital fluorescence display effect.

Oscilloscope display showing decoded serial data alongside the raw waveform.

Figure 5.4: Digital Decoding Example

The decoding feature displays protocol information directly on the screen, simplifying debugging of serial communications.

5.5 Data Storage and Connectivity

6. Održavanje

6.1 Opšta njega

6.2 Čišćenje

Za čišćenje vanjštine osciloskopa:

  1. Disconnect the power cord and all probes/cables.
  2. Koristite meku krpu dampened with mild detergent and water. Do not use abrasive cleaners or solvents.
  3. For the display, use a soft, lint-free cloth specifically designed for electronic screens.
  4. Ensure the instrument is completely dry before reconnecting power.

7. Otkrivanje problema

This section addresses common issues you might encounter with the UPO1102 oscilloscope. For problems not listed here, contact UNI-T customer support.

ProblemMogući uzrokRješenje
Nema prikaza nakon uključivanja.Power cord not connected, power outlet faulty, instrument fault.Check power cord connection. Test power outlet. If problem persists, contact support.
Nije prikazan talasni oblik.Probe not connected, signal too small/large, trigger not set correctly, channel off.Ensure probe is connected to signal source. Press Auto button. Adjust vertical scale (Volts/Div) and horizontal scale (Sec/Div). Check trigger level. Ensure channel is enabled.
Nestabilan talasni oblik.Trigger level incorrect, trigger mode unsuitable, signal noise.Adjust trigger level. Try different trigger modes (e.g., Normal or Single). Reduce noise in the signal path.
Incorrect measurements.Probe compensation incorrect, probe attenuation setting wrong, measurement settings incorrect.Perform probe compensation (Section 4.3). Verify probe attenuation setting matches physical probe (e.g., 1X, 10X). Check measurement parameters.

8. Specifikacije

ParametarVrijednost
Bandwidth100 MHz
Kanali2
S. u realnom vremenuample Rate1 GSa/s
Dubina memorije56 Mpts
Brzina snimanja talasnog oblika500,000 riječi u minuti/s
Display7 inča
Brza brzina prevođenja (FFT)ampling Points1 Mpts
Dimenzije proizvoda13 x 4 x 6 inča (približno 330 x 102 x 152 mm)
Težina artikla8.13 funte (otprilike 3.69 kg)
ProizvođačUNI-T
ASINB0D7F2D9MS
Datum prve dostupnosti19. juna 2024

9. Garancija i podrška

For warranty information, technical support, or service inquiries regarding your UNI-T UPO1102 oscilloscope, please refer to the official UNI-T webstranice ili kontaktirajte njihov odjel za korisničku podršku.

UNI-T Official Store: Visit the UNI-T Store on Amazon

Please have your product model (UPO1102) and ASIN (B0D7F2D9MS) available when contacting support.

Povezani dokumenti - UPO1102

Preview UNI-T UT-PA2000/UT-PA1000 Uputstvo za upotrebu aktivne jednostrane sonde
Ovaj korisnički priručnik pruža sveobuhvatne informacije o aktivnim jednostranim sondama UNI-T UT-PA2000 i UT-PA1000, obuhvatajući njihove karakteristike, specifikacije, sigurnosne smjernice, rad, održavanje i garanciju.
Preview Kratki vodič za digitalni fosforni osciloskop serije UNI-T UPO1000
Sažet i SEO optimiziran HTML vodič za digitalni fosforni osciloskop serije UNI-T UPO1000, koji pokriva sigurnost, podešavanje, rad i rješavanje problema. Uključuje detaljne opise prednje/zadnje ploče i elemenata korisničkog sučelja.
Preview Uputstvo za upotrebu ultra fosfornog osciloskopa serije UNI-T UPO2000E
Sveobuhvatno korisničko uputstvo za ultra fosforni osciloskop serije UNI-T UPO2000E, koje obuhvata rad, sigurnost, karakteristike i specifikacije za modele kao što su UPO2072E, UPO2102E, UPO2074E i UPO2104E.
Preview Uputstvo za upotrebu osciloskopa miješanih signala serije MSO7000X
User's manual for the MSO7000X Series Mixed Signal Oscilloscope, detailing its features, operation, safety precautions, and technical specifications. Covers setup, vertical and horizontal systems, trigger system, protocol decoding, measurements, mathematical operations, and troubleshooting.
Preview UNI-T MSO1000HD Series High-Resolution Oscilloscopes Data Sheet
Comprehensive data sheet for the UNI-T MSO1000HD Series High-Resolution Oscilloscopes, detailing features, specifications, performance characteristics, probes, accessories, and order information.
Preview Tehnički list osciloskopa miješanih signala serije UNI-T MSO3000X
Tehnički list za osciloskop miješanih signala serije UNI-T MSO3000X, s detaljnim opisom njegovih karakteristika, specifikacija i mogućnosti, uključujući propusni opseg od 500 MHz i 5 GSA/ss.ampbrzina prenosa podataka i interfejs osjetljiv na dodir od 10.1 inča.