TOSOT 60,00BTU-50ft

TOSOT 60,000 BTU (5 Ton) Ducted Central Air Conditioner Heat Pump System

Model: 60,00BTU-50ft

Brand: TOSOT

1. Uvod

This manual provides comprehensive instructions for the installation, operation, and maintenance of your TOSOT 60,000 BTU (5 Ton) Ducted Central Air Conditioner Heat Pump System. Please read this manual thoroughly before installation and use to ensure proper function and safety. Keep this manual for future reference.

Važne informacije o sigurnosti

  • Potrebna profesionalna instalacija: This system requires installation by a certified HVAC technician for optimal performance and safety. DIY installation is not recommended.
  • električna sigurnost: Ensure all electrical connections comply with local codes and standards. Disconnect power before any service or maintenance.
  • Rukovanje rashladnim sredstvom: This system uses R-32 refrigerant. Only qualified personnel should handle refrigerant.
  • Read All Warnings: Pay close attention to all warning labels on the unit and throughout this manual.

2. Proizvod je gotovview

The TOSOT 60,000 BTU (5 Ton) Ducted Central Air Conditioner Heat Pump System is an inverter split system designed for efficient heating and cooling. It features advanced technology for reliable operation in various climates.

Uključene komponente

  • Vanjska kondenzacijska jedinica
  • Jedinica za obradu zraka u zatvorenom prostoru
  • 50-foot Copper Line Set
  • Installation Kit (includes sealing gum, wall cap, wall sleeve, tapes, and user manual)
TOSOT 60,000 BTU Ducted Central Air Conditioner Heat Pump System with Outdoor Condenser, Indoor Air Handler, and 50-foot Copper Line Set

Figure 2.1: Complete TOSOT Central Air Conditioner Heat Pump System with included components.

Video 2.1: Krajview of the TOSOT Central Air Conditioner Heat Pump System, highlighting its main units and features.

3. Ključne karakteristike

3.1. UltraCool & UltraHeat Technology

This system provides efficient heating and cooling across a wide temperature range, from -22℉ to 130℉, ensuring comfort in extreme conditions.

Graph illustrating UltraCool and UltraHeat performance across extreme temperatures from -22°F to 130°F

Figure 3.1: Performance capabilities of UltraCool and UltraHeat technology in varying outdoor temperatures.

3.2. Self-Developed Inverter Compressor

The system utilizes a triple-cylinder two-stage rotary compressor with enhanced vapor injection technology. This design optimizes low-temperature heating, maintaining 100% heating capacity at -5℉ and 100% cooling performance at 115℉.

Diagram showing the DC Inverter Compressor with specifications for SEER2, HSPF2, efficiency, and noise level

Figure 3.2: Details of the DC Inverter Compressor, highlighting its efficiency and low noise operation.

Video 3.1: Demonstration of the Central AC Heat Pump with Inverter Technology, showcasing njegove operativne prednosti.

Video 3.2: Visual explanation of the Central AC Split System Heat Pump with Inverter, detailing its components and function.

3.3. Energetska efikasnost

With ratings up to 18.5 SEER2 and 10.5 HSPF2, this system offers significant energy savings. Inverter technology can provide up to 30% more energy savings compared to non-inverter systems with the same SEER2 rating. It is Energy Star certified and may qualify for federal tax credits.

TOSOT outdoor condenser unit with Energy Star, ETL, AHRI Certified, and NEEP logos, indicating superior energy efficiency

Figure 3.3: Energy Star and other certifications for the TOSOT Heat Pump System.

3.4. Upgraded Condenser Design

The slim design of the outdoor condenser unit requires less space, making it suitable for constricted areas. Its side discharge design minimizes debris accumulation and keeps noise levels below 63 dB.

Comparison of TOSOT APEX Condenser (slim, side discharge) with Traditional Condenser (large, top discharge)

Figure 3.4: Comparison of TOSOT APEX Condenser design with traditional condensers.

3.5. High Static Pressure Design

The TOSOT unitary central AC adapts to actual static pressure, making it ideal for areas requiring long-distance airflow. It offers eight adjustable fan speeds to meet the needs of various living spaces.

Diagram showing high static pressure fan features: 8 adjustable fan speeds, adapts to actual static pressure, suitable for diverse living spaces

Figure 3.5: Benefits of the High Static Pressure Fan for optimized airflow.

3.6. Multipositional Air Handler

The indoor air handler unit can be installed horizontally or vertically, providing flexible installation options for basements, attics, and both residential and commercial spaces.

Illustrations showing horizontal and vertical installation options for the TOSOT indoor air handler unit

Figure 3.6: Flexible installation configurations for the indoor air handler.

4. Specifikacije

FeatureSpecifikacija
BrandTOSOT
Model60,00BTU-50ft
Kapacitet5 tone (60,000 BTU)
Snaga hlađenja53,000 britanskih termalnih jedinica
Sezonski omjer energetske efikasnosti (SEER2)18.5
Faktor sezonskog učinka grijanja (HSPF2)10.5
Nivo buke63 Decibels (Outdoor Condenser)
Raspon radne temperature-22℉ do 130℉
Tip kompresoraInverter, Triple-Cylinder Two-Stage Rotary
Rashladno sredstvoR-32
Voltage230 Volts
Wattage16,120 vati
Dimenzije vanjskog kondenzatora (D x Š x V)13.4" x 35.4" x 49.6"
Indoor Air Handler Dimensions (D x W x H)21.3" x 24.8" x 52.0"
Težina artikla241 funte
Pokrivenost podaDo 3000 kvadratnih stopa
Dužina postavljene linije50 feet (Copper)
CertifikatiEnergy Star, ETL, AHRI Certified

5. Postavljanje i instalacija

The TOSOT Central Air Conditioner Heat Pump System is a complex appliance that requires professional installation. Attempting to install this unit without proper certification and tools can lead to serious injury, property damage, and void the product warranty.

5.1. Razmatranja prije instalacije

  • Lokacija: Choose appropriate locations for both the outdoor condenser and indoor air handler, considering airflow, noise, and accessibility for maintenance. The multipositional air handler allows for vertical or horizontal installation.
  • Električni zahtjevi: Ensure the electrical supply meets the 230V requirement and is properly grounded.
  • Kanali: Verify existing ductwork is compatible and in good condition for efficient air distribution. The high static pressure design is suitable for long-distance airflow.
  • Termostat: This system is compatible with universal 24V thermostats (not included).
Diagram showing a 24V thermostat connected to the central AC system

Figure 5.1: Universal 24V thermostat compatibility.

5.2. Professional Installation Steps (Summary)

  1. Mount the indoor air handler in the chosen vertical or horizontal position.
  2. Position the outdoor condenser unit, ensuring adequate clearance for airflow.
  3. Connect the 50-foot copper line set between the indoor and outdoor units.
  4. Perform all necessary electrical wiring connections.
  5. Connect the thermostat wiring.
  6. Evacuate the refrigerant lines and charge the system with R-32 refrigerant.
  7. Test the system for proper operation, including airflow and temperature control.
Image emphasizing professional installation for the central air conditioning system

Figure 5.2: Professional installation is crucial for system integrity and safety.

6. Uputstvo za upotrebu

Once professionally installed, your TOSOT Heat Pump System is controlled via a compatible 24V thermostat. Refer to your thermostat's user manual for specific programming and operation details.

6.1. Osnovni rad

  • Uključivanje/isključivanje: Use your thermostat to turn the system on or off.
  • Odabir načina rada: Select desired operating mode (Cool, Heat, Fan, Auto) on your thermostat.
  • Postavka temperature: Podesite željenu temperaturu pomoću kontrola termostata.

6.2. Podešavanje brzine ventilatora

The system features eight adjustable fan speeds. Your installer can configure these settings to optimize airflow and comfort for your specific ductwork and living space. Consult your installer or thermostat manual for how to adjust fan speeds if accessible to the user.

7. Održavanje

Regular maintenance is essential to ensure the longevity and efficient operation of your TOSOT Heat Pump System. It is recommended to schedule annual professional maintenance.

7.1. Zamjena filtera

Regularly check and replace the air filter in your indoor air handler. A dirty filter restricts airflow and reduces efficiency. The recommended filter size is 20x23 inches, though some documentation may incorrectly state 20x20 inches. Verify the actual size of your installed filter.

7.2. Outdoor Condenser Cleaning

Keep the area around the outdoor condenser unit clear of debris, leaves, and vegetation to ensure proper airflow. The side discharge design helps minimize accumulation, but periodic inspection is still advised.

7.3. Profesionalno servisiranje

Schedule annual maintenance with a certified HVAC technician. This includes checking refrigerant levels, inspecting electrical components, cleaning coils, and verifying overall system performance.

8. Otkrivanje problema

If you experience issues with your system, perform the following basic checks before contacting a service technician:

  • Nema napajanja: Check the circuit breaker for the unit. Ensure the thermostat is set to the desired mode and temperature.
  • Nedovoljno hlađenje/grijanje: Verify the thermostat settings. Check if the air filter is clean. Ensure outdoor unit is free of obstructions.
  • Neobični zvukovi: Minor operational noises are normal. If you hear loud or unusual sounds, contact a technician.
  • Curenje vode: Check the condensate drain line for blockages.

For any persistent issues or complex problems, contact a certified HVAC technician for diagnosis and repair.

9. Garancija i podrška

9.1. Informacije o garanciji

The TOSOT 60,000 BTU Ducted Central Air Conditioner Heat Pump System comes with a pet godina garancije. Please retain your proof of purchase and installation records for warranty claims. The warranty covers defects in materials and workmanship under normal use and service.

For specific terms and conditions of the warranty, refer to the warranty card included with your product or contact TOSOT customer support.

9.2. Korisnička podrška

For technical assistance, troubleshooting, or warranty inquiries, please contact TOSOT customer support:

  • Webstranica: [Insert TOSOT Support Webstranica ovdje]
  • Telefon: [Insert TOSOT Support Phone Number Here]
  • Email: [Insert TOSOT Support Email Here]

When contacting support, please have your model number (60,00BTU-50ft) and date of purchase readily available.

Povezani dokumenti - 60,00BTU-50ft

Preview TOSOT uputstvo za upotrebu split klima uređaja
Sveobuhvatno uputstvo za upotrebu TOSOT split klima uređaja, koje obuhvata sigurnosne mjere predostrožnosti, instalaciju, rad, održavanje i rješavanje problema za modele poput TWH09AT19A6A i drugih jedinica serije TWH.
Preview Specifikacije i dimenzije TOSOT split klima uređaja
Detaljne tehničke specifikacije, podaci o performansama i fizičke dimenzije za TOSOT klima uređaje split tipa: TM18HMO, TM24HMO, TM30HMO, TM36HMO i TM42HMO.
Preview TOSOT Vodič za instalaciju klima uređaja za kampere
Detaljne upute za ugradnju TOSOT klima uređaja za kampere, brtvljenje poklopca, montažu uređaja, ugradnju ploče kanala, okvir stropa, ožičenje i montažu rešetke.
Preview TOSOT 8,000 BTU Uputstvo za upotrebu klima uređaja za prozore | Instalacija, rad i rješavanje problema
Sveobuhvatno korisničko uputstvo za TOSOT klima uređaj za prozore od 8,000 BTU (Model GJC08BU-A6NRNJ2A). Obuhvata instalaciju, rad, daljinsko upravljanje, čišćenje, održavanje, rješavanje problema i sigurnosne upute.
Preview TOSOT Clivia Deluxe TH-SCD klima uređaj - uputstvo za upotrebu
Sveobuhvatno korisničko uputstvo za klima uređaje TOSOT Clivia Deluxe TH-SCD serije, koje obuhvata karakteristike, rad, specifikacije, održavanje i sigurnost. Uključuje informacije o rashladnom sredstvu R32 i detalje o WiFi povezivosti.
Preview TOSOT Split-Type Floor-Standing Air Conditioner User Manual
Comprehensive user manual for the TOSOT Split-Type Floor-Standing Air Conditioner, covering installation, operation, maintenance, safety precautions, and troubleshooting. Includes model SU-COSMO36FS/I.