This manual provides essential information for the safe and efficient operation of your Generac 200 Amp Single Phase Automatic Smart Transfer Switch Kit and the Generac 7101 Battery Heater Pad. This combined system is designed to ensure continuous power supply during utility outages and maintain optimal battery performance for your standby generator.

The Generac Automatic Transfer Switch is engineered for use with single-phase generators equipped with an Evolution or Nexus Controller. It monitors utility power and automatically transfers the electrical load between utility and generator power, ensuring seamless operation. Its Digital Power Management (DPM) technology allows for the management of up to four individual HVAC (24 VAC controlled) loads without additional hardware.

The Generac 7101 Battery Heater Pad is designed to maintain the optimal temperature of your generator's battery, especially in colder climates. It activates automatically to prevent performance degradation due to low temperatures.

Generac 200 Amp Automatic Smart Transfer Switch Kit and Battery Heater Pad

Slika 1: Gotovoview of the Generac 200 Amp Automatic Smart Transfer Switch Kit and 7101 Battery Heater Pad, showing the transfer switch enclosure, battery heater pad, and associated wiring/ties.

2. Sigurnosne informacije

UPOZORENJE: Installation and service must be performed by a qualified electrician or service technician. Improper installation or maintenance can result in serious injury, death, or property damage.

  • Always disconnect all power sources before servicing the transfer switch or battery heater pad.
  • Osigurajte da se tokom instalacije poštuju svi lokalni električni propisi i zakoni.
  • Nosite odgovarajuću ličnu zaštitnu opremu (LZO), uključujući zaštitne naočale i izolirane rukavice.
  • Do not operate the transfer switch or heater pad if any components are damaged.
  • Keep children and unauthorized personnel away from the equipment.

3. Komponente proizvoda

The Generac 200 Amp Automatic Smart Transfer Switch Kit and 7101 Battery Heater Pad include the following main components:

  • Generac 200 Amp Automatic Smart Transfer Switch: Housed in an aluminum NEMA/UL type 3R enclosure.
  • Generac 7101 Battery Heater Pad: Designed for 9kW-22kW air-cooled standby generators.
  • Associated wiring and installation accessories (e.g., cable ties).
Exterior of Generac 200 Amp Automatic Smart Transfer Switch

Slika 2: Vanjski dio view of the Generac 200 Amp Automatic Smart Transfer Switch enclosure.

Interior of Generac 200 Amp Automatic Smart Transfer Switch

Slika 3: Unutrašnjost view of the Generac 200 Amp Automatic Smart Transfer Switch, showing internal components and wiring terminals.

Generac 7101 Battery Heater Pad with wiring

Figure 4: The Generac 7101 Battery Heater Pad, including its power cable and connection points.

4. Postavljanje i instalacija

Proper installation is crucial for the safe and effective operation of your transfer switch and battery heater pad. It is highly recommended that installation be performed by a certified electrician or Generac authorized service dealer.

4.1. Automatic Transfer Switch Installation

  1. Odabir lokacije: Choose a location for the transfer switch that is accessible, protected from severe weather, and in close proximity to both the utility meter and the generator. The NEMA 3R enclosure is suitable for outdoor use.
  2. Montaža: Securely mount the transfer switch enclosure to a sturdy surface using appropriate hardware. Ensure it is level and plumb.
  3. Ožičenje:
    • Utility Power: Connect the utility power lines to the designated terminals within the transfer switch. This unit includes a service disconnect.
    • Generator Power: Connect the generator power lines to the appropriate terminals.
    • Učitavanje konekcija: Connect the household electrical load to the transfer switch output terminals.
    • Kontrolno ožičenje: Povežite nisku jačinu zvukatage control wires between the transfer switch and the generator's Evolution or Nexus Controller. Refer to your generator's manual for specific control wiring diagrams.
  4. Uzemljenje i spajanje: Ensure proper grounding and neutral bonding as per local electrical codes.
  5. Završne provjere: Before restoring power, double-check all connections for tightness and correct polarity.
Ugaona unutrašnjost view of Generac 200 Amp Automatic Smart Transfer Switch

Figure 5: Angled interior view of the transfer switch, highlighting the utility source connections (N1, N2), generator source, and customer load connections.

4.2. Battery Heater Pad Installation

The Generac 7101 Battery Heater Pad is designed for easy installation under the generator battery. It is compatible with air-cooled standby generators manufactured in 2008 or later. Note: This heater pad is not required for use with AGM-style batteries.

  1. Vađenje baterije: Carefully disconnect and remove the generator battery from its tray.
  2. Pad Placement: Place the Generac 7101 Battery Heater Pad directly onto the battery tray, ensuring it is centered and flat.
  3. Battery Reinstallation: Carefully place the battery back onto the heater pad in the tray. Reconnect the battery terminals, ensuring correct polarity.
  4. Ožičenje: Connect the heater pad's wiring to the designated low-voltage power source on your generator, as specified in your generator's installation manual.
  5. Sigurno ožičenje: Use the provided cable ties to secure the heater pad wiring, preventing it from interfering with moving parts or being damaged.
Close-up of Generac 7101 Battery Heater Pad connector

Slika 6: Krupni plan view of the connector for the Generac 7101 Battery Heater Pad.

Close-up of Generac 7101 Battery Heater Pad wiring

Slika 7: Detaljno view of the wiring for the Generac 7101 Battery Heater Pad.

5. Uputstvo za upotrebu

5.1. Automatic Transfer Switch Operation

The Generac Automatic Transfer Switch operates autonomously to manage your home's power supply.

  1. Utility Power Monitoring: The transfer switch continuously monitors the incoming utility power for interruptions or significant voltage fluktuacije.
  2. Automatic Transfer to Generator: Upon detecting a utility power outage, the transfer switch signals the standby generator to start. Once the generator reaches proper operating voltage and frequency, the transfer switch automatically disconnects the home from utility power and connects it to the generator power. This process is seamless and typically occurs within seconds.
  3. Digital Power Management (DPM): The integrated DPM allows the transfer switch to manage up to four 24 VAC controlled HVAC loads. During generator operation, if the total load approaches the generator's capacity, the DPM will shed non-essential HVAC loads to prevent overload, then reconnect them as capacity becomes available.
  4. Return to Utility Power: When stable utility power is restored, the transfer switch monitors it for a pre-set period to ensure stability. Once confirmed, it automatically transfers the electrical load back to utility power and signals the generator to cool down and shut off.

5.2. Battery Heater Pad Operation

The Generac 7101 Battery Heater Pad operates automatically based on ambient temperature to ensure your generator's battery remains at an optimal temperature for starting.

  • Automatsko aktiviranje: The heater pad is equipped with a thermostat that activates the heating element when the ambient temperature drops to approximately 40°F (4.4°C).
  • Automatsko deaktiviranje: The heater pad will turn off when the battery temperature reaches approximately 55°F (12.8°C), preventing overheating and conserving energy.
  • Kontinuirano praćenje: The heater pad continuously monitors the temperature, cycling on and off as needed to maintain the battery within the optimal temperature range.

6. Održavanje

Regular maintenance ensures the longevity and reliable operation of your Generac transfer switch and battery heater pad. It is recommended to have these components inspected annually by a qualified technician as part of your generator's maintenance schedule.

  • Vizuelni pregled: Periodically inspect the transfer switch enclosure for any signs of damage, corrosion, or loose connections. Ensure the enclosure is sealed and free from debris.
  • Provjera ožičenja: Verify that all wiring connections are secure and free from fraying or damage.
  • čistoća: Keep the exterior of the transfer switch and the area around the battery heater pad clean and free of obstructions.
  • Zdravlje baterije: Regularly check your generator's battery health. While the heater pad helps with temperature, the battery itself still requires proper charging and occasional testing.
  • Profesionalna usluga: For internal components of the transfer switch or any electrical issues, contact a Generac authorized service dealer. Do not attempt to service internal electrical components yourself.

7. Otkrivanje problema

This section provides basic troubleshooting steps for common issues. For complex problems, always contact a qualified Generac service technician.

ProblemMogući uzrokRješenje
Transfer switch does not transfer to generator during outage.
  • Generator not starting.
  • Problem s upravljačkim ožičenjem.
  • Transfer switch malfunction.
  • Check generator fuel, oil, and battery.
  • Verify control wiring connections between switch and generator.
  • Za dijagnostiku se obratite kvalificiranom tehničaru.
Transfer switch does not return to utility power.
  • Utility power not stable.
  • Transfer switch malfunction.
  • Wait for utility power to stabilize.
  • Obratite se kvalifikovanom tehničaru.
Battery heater pad not warming battery.
  • Temperature above activation threshold.
  • Slabo ožičenje.
  • Heater pad malfunction.
  • Check ambient temperature (should be below 40°F/4.4°C).
  • Inspect wiring connections to the heater pad.
  • Obratite se kvalifikovanom tehničaru.

Važno: Ne pokušavajte električne popravke ako niste kvalifikovani. Uvijek dajte prioritet sigurnosti.

8. Specifikacije

FeatureSpecifikacija
Način radaAutomatski
Current Rating200 Amps
Operating Voltage240 Volts
Vrsta kontaktaNormalno otvoren
Tip konektora2 Pin
TerminalScrew
Tip kruga1-way
Tip aktuatoraHinge Lever
Kontakt materijalČelik
Međunarodna ocjena zaštiteIP67
Broj pozicija1
Specifikacija MetUL
Lower Temperature Rating (Heater Pad Activation)40 stepena Fahrenheita (4.4°C)
Upper Temperature Rating (Heater Pad Deactivation)55 stepena Fahrenheita (12.8°C)
Kontrolni metodTouch (for DPM interface, if applicable)
Connectivity ProtocolX-10 (for DPM, if applicable)
BojaOrange (Heater Pad)
Wattage6000 Watts (General product specification)
Unit Count1.0 Count
Broj stavki1
ProizvođačGenerac
MaterijalSteel (Transfer Switch Enclosure)

Napomena: Specifikacije se mogu promijeniti bez prethodne najave. Za najtačnije informacije pogledajte etiketu proizvoda.

9. Garancija i podrška

garancija: The Generac 200 Amp Automatic Smart Transfer Switch comes with a 5 godine ograničene garancije. The Generac 7101 Battery Heater Pad is also covered by Generac's standard accessory warranty. Please retain your proof of purchase for warranty claims.

Podrška: For technical assistance, troubleshooting beyond this manual, warranty service, or to locate an authorized Generac service dealer, please visit the official Generac website or contact Generac customer support.

Visit the Official Generac Store on Amazon

Povezani dokumenti - RXSW200A3 & 7101

Preview Generac generatori: prenosiva, stambena i komercijalna rješenja
Istražite Generac-ovu sveobuhvatnu ponudu generatora, uključujući prenosive, stambene i komercijalne sisteme. Saznajte više o karakteristikama, specifikacijama i primjenama za pouzdana rješenja za napajanje.
Preview Generac HTS "Wn" Type Automatic Transfer Switch Owner's Manual
Owner's Manual for the Generac HTS "Wn" Type Automatic Transfer Switch, detailing installation, operation, and maintenance for models 600-2600 Amp, 600 Volts.
Preview Generac HS Type Automatic Transfer Switch Owner's Manual
Comprehensive owner's manual for Generac HS Type Automatic Transfer Switches (ATS), models 005036-0 (100A) and 004945-1 (200A). Covers installation, operation, safety guidelines, electrical data, diagrams, and warranty information.
Preview Generac 60 Hz Air-Cooled Generators Installation Guidelines (16kW & 22kW)
Detailed installation guide for Generac 60 Hz air-cooled standby generators (16kW and 22kW models). Covers essential steps from unpacking and site selection to electrical connections and initial startup, ensuring safe and proper setup for reliable backup power.
Preview Uputstvo za upotrebu Generac 60 Hz generatora sa vazdušnim hlađenjem (10-24 kW)
Sveobuhvatno uputstvo za upotrebu Generac 60 Hz generatora sa vazdušnim hlađenjem, koje obuhvata rad, održavanje, sigurnost i rešavanje problema za modele snage od 10 kW do 24 kW.
Preview Generac Guardian Series Residential Standby Generators (20-24 kW) - Features & Specifications
Explore the Generac Guardian Series residential standby generators (20, 22, and 24 kW). This document details key features, advanced technology like True Power™ and Mobile Link™, comprehensive specifications, and compatible accessories for reliable home backup power.