First Alert SMI100-AC

First Alert SMI100-AC Hardwire Interconnect Smoke Alarm

Uputstvo za upotrebu

Uvod

This manual provides essential information for the installation, operation, and maintenance of your First Alert SMI100-AC Hardwire Interconnect Smoke Alarm with Battery Backup. This device is designed to provide early warning of smoke and fire hazards in residential environments. It features Precision Detection advanced sensing technology and the ability to interconnect with compatible alarms for whole-home coverage.

Važne informacije o sigurnosti

Sadržaj paketa

Prije početka instalacije provjerite da li su sve komponente prisutne:

First Alert SMI100-AC smoke alarm components including the alarm unit, mounting bracket, quick connect plug, 9V battery, and mounting hardware.

Image: Components of the First Alert SMI100-AC smoke alarm, showing the main unit, mounting ring, wiring harness, battery, and screws.

Instalacija

Proper placement and installation are crucial for effective smoke detection.

Preporučeni plasman

Install smoke alarms on every level of your home, including basements and in every bedroom. For optimal protection, place alarms in hallways outside sleeping areas and in living rooms. Avoid placing alarms in kitchens, bathrooms, or garages where steam, cooking fumes, or exhaust can cause nuisance alarms.

Diagram illustrating recommended placement of smoke alarms, carbon monoxide alarms, and fire extinguishers in a multi-level home.

Image: A diagram showing recommended locations for smoke alarms, carbon monoxide alarms, and fire extinguishers throughout a typical house layout, including bedrooms, hallways, living room, kitchen, basement, and garage.

Upute za ožičenje

  1. Isključite napajanje: Before installation, ensure the power to the circuit where the alarm will be installed is turned off at the main fuse box or circuit breaker.
  2. Montažni nosač: Secure the mounting bracket to the electrical box using the provided screws. Ensure the bracket is firmly attached.
  3. Povežite ožičenje: Connect the Quick Connect Plug wiring harness to your household wiring. Typically, this involves connecting black to black (hot), white to white (neutral), and orange to orange (interconnect, if applicable). Use wire nuts to secure connections.
  4. Instalirajte bateriju: Open the battery compartment on the back of the smoke alarm unit. Insert the 9V alkaline battery, ensuring correct polarity (+ to + and - to -). Close the battery compartment.
  5. Priključite alarmnu jedinicu: Plug the Quick Connect Plug into the receptacle on the back of the smoke alarm unit. Align the alarm unit with the mounting bracket and twist clockwise until it locks securely into place.
  6. Vrati snagu: Turn the power back on at the circuit breaker. The green power indicator light on the alarm should illuminate, indicating it is receiving AC power.
  7. Test alarma: Press and hold the Test/Silence button for a few seconds until the alarm sounds. This confirms the unit is functioning correctly.
First Alert SMI100-AC smoke alarm with a Quick Connect Plug, highlighting easy installation without rewiring.

Image: A close-up of the First Alert SMI100-AC smoke alarm unit, emphasizing the Quick Connect Plug feature for simplified installation.

Operacija

Testiranje alarma

Test your smoke alarm weekly to ensure it is operating correctly. Press and hold the Test/Silence button on the alarm cover until the alarm sounds. The alarm will emit a loud, pulsating sound. If the alarm does not sound, refer to the Troubleshooting section.

Funkcija tišine

If a nuisance alarm occurs (e.g., from cooking smoke), you can temporarily silence the alarm by pressing the Test/Silence button. The alarm will remain silent for approximately 10 minutes before resetting. If the smoke is still present after the silence period, the alarm will sound again.

Interconnect Feature

When one interconnected alarm detects smoke, all compatible interconnected alarms in your home will sound. This provides an early warning system throughout your residence.

Indikatorska svjetla

Front view of the First Alert SMI100-AC smoke alarm showing the test/silence button and indicator lights.

Slika: Detaljna view of the First Alert SMI100-AC smoke alarm's front, highlighting the Test/Silence button and the power indicator light.

Održavanje

Čišćenje vašeg dimnog alarma

Clean your smoke alarm regularly to prevent dust and debris from interfering with its operation. Use a soft brush attachment on your vacuum cleaner to gently remove dust from the alarm's vents. Do not use cleaning solvents or spray directly onto the alarm.

Zamjena baterije

The 9V battery provides backup power during outages. Replace the battery annually, or immediately if the alarm emits a low battery chirp. To replace the battery:

  1. Turn off AC power to the alarm at the circuit breaker.
  2. Twist the alarm counter-clockwise to remove it from the mounting bracket.
  3. Otvorite pretinac za baterije i izvadite staru bateriju.
  4. Insert a new 9V alkaline battery, observing polarity.
  5. Close the battery compartment and reattach the alarm to the mounting bracket by twisting clockwise.
  6. Restore AC power and test the alarm.

End of Life Replacement

Smoke alarms have a limited lifespan. This First Alert SMI100-AC alarm should be replaced 10 years after its manufacture date. The manufacture date is printed on the back of the alarm unit.

Rješavanje problema

ProblemMogući uzrokRješenje
Alarm se oglašava povremeno ili bez ikakvog vidljivog razloga.Nuisance alarm from cooking, steam, or dust.Press the Test/Silence button. Clean the alarm. Relocate if consistently triggered by non-fire sources.
Alarm se oglašava svakih 30-60 sekundi.Niska baterija.Odmah zamijenite 9V bateriju.
Alarm se ne oglašava tokom testiranja.No AC power, dead battery, or faulty unit.Check circuit breaker. Ensure battery is installed correctly and is fresh. Replace the unit if issues persist.
Zelena LED dioda je isključena.Nema AC napajanja.Provjerite prekidač i spojeve ožičenja.

Specifikacije

Garancija i podrška

For warranty information and technical support, please refer to the documentation included with your product or visit the official First Alert webSačuvajte račun kao dokaz o kupovini za reklamacije u slučaju reklamacije.

Online podrška: www.firstalert.com

Povezani dokumenti - SMI100-AC

Preview First Alert SMI100-AC Hardwired Smoke Alarm User Manual and Installation Guide
Comprehensive user manual and installation guide for the First Alert SMI100-AC Hardwired Smoke Alarm with Battery Backup. Learn about features, installation, testing, maintenance, troubleshooting, warranty, and safety guidelines.
Preview First Alert 3120B Foto i Ionski Detektor Dima Uputstvo za Korišćenje
Ovaj korisnički priručnik pruža sveobuhvatne upute za First Alert 3120B foto i ionizacijski detektor dima s napajanjem izmjeničnom strujom i rezervnom baterijom. Obuhvata instalaciju, rad, održavanje, sigurnosne savjete, rješavanje problema i informacije o garanciji za optimalnu zaštitu od požara.
Preview First Alert SC7010BV Detektor dima i ugljičnog monoksida Uputstvo za upotrebu
Sveobuhvatni korisnički priručnik za First Alert SC7010BV alarm za dim i ugljični monoksid s napajanjem izmjeničnom strujom, s detaljnim opisom instalacije, rada, održavanja, sigurnosnih značajki i rješavanja problema.
Preview First Alert BRK Smoke and Smoke/CO Detectors: User Manuals & Installation Guides
Comprehensive user manuals and installation guides for First Alert BRK 3120B-6 Smoke Detector and SC7010BV Smoke & Carbon Monoxide Detector. Learn about features, installation, safety, and troubleshooting for these essential home safety devices.
Preview First Alert SA520A Uputstvo za upotrebu detektora dima: Instalacija i rad
Comprehensive user manual for the First Alert SA520A smoke alarm. Learn about its AC power with battery backup, wireless interconnect features, installation steps, maintenance, and important fire safety tips for early warning and home protection.
Preview First Alert 9120/9120B AC detektor dima - uputstvo za upotrebu
Sveobuhvatni korisnički priručnik za First Alert i BRK 9120 i 9120B jonizacijske detektore dima s napajanjem izmjeničnom strujom i rezervnom baterijom. Obuhvata instalaciju, rad, održavanje, karakteristike, rješavanje problema i savjete za zaštitu od požara.