GENMAX GM-PUMP

GENMAX 12V DC Electric Fuel Pump GMEFP Instruction Manual

Model: GM-PUMP

1. Uvod

The GENMAX GMEFP is a 12V DC electric fuel pump designed to automatically transfer gasoline from an external fuel tank to your GENMAX small inverter generator. This system ensures continuous operation of your generator without manual refueling, enhancing convenience and efficiency.

This manual provides essential information for the safe and effective installation, operation, and maintenance of your GENMAX GMEFP fuel pump. Please read it thoroughly before use and retain it for future reference.

GENMAX GMEFP Electric Fuel Pump
Image 1.1: The GENMAX GMEFP 12V DC Electric Fuel Pump, designed for automatic fuel transfer.

2. Sigurnosne informacije

UPOZORENJE: Benzin je lako zapaljiv, a njegove pare su eksplozivne. Uvijek rukujte gorivom s izuzetnim oprezom.

3. Značajke proizvoda

4. Sadržaj paketa

Provjerite da li se u vašem paketu nalaze sve dolje navedene stavke:

GENMAX GMEFP Fuel Pump and Accessories
Image 4.1: The GENMAX GMEFP fuel pump shown with its included accessories: 12V DC power plugs (crocodile clips and cigarette lighter type) and a fuel hose with a primer bulb. These components facilitate connection to various power sources and external fuel tanks.

5. Postavljanje i instalacija

Proper installation is crucial for the safe and efficient operation of the fuel pump. Follow these steps carefully:

5.1 Provjera prije instalacije

GENMAX GMEFP Fuel Pump Dimensions and Thread Size
Image 5.1: Detailed dimensions of the GENMAX GMEFP fuel pump, including thread size (1.95 inches diameter, 0.18 inches pitch) and overall height (7.3 inches), crucial for compatibility with external fuel tanks.

5.2 Connecting the Fuel Pump

  1. Install the Fuel Pump: Securely screw the GENMAX GMEFP fuel pump into the fuel tank opening of your generator. Ensure a tight seal to prevent leaks.
  2. Connect Fuel Hose to External Tank: Connect one end of the provided fuel hose (with the primer bulb) to the outflow port of your external fuel tank. Ensure this connection is secure.
  3. Connect Fuel Hose to Pump: Connect the other end of the fuel hose to the tubing connection port on the GENMAX GMEFP fuel pump. This port indicates fuel flow to the generator.
  4. Priključite napajanje: Choose the appropriate 12V DC power plug (crocodile clips or cigarette lighter) and connect it to the 12V DC power cable of the fuel pump. Then, connect the power plug to your generator's 12V DC output or another suitable 12V DC power source.
  5. Pozicioniranje: Place the external fuel tank on a stable surface, ensuring it is below the generator's fuel tank for optimal gravity feed assistance during priming. Ensure the fuel hose is not kinked and is clear of hot engine components, especially the muffler.
GENMAX GMEFP Fuel Pump Connection Diagram
Image 5.2: Diagram illustrating the connection of the GENMAX GMEFP fuel pump to a generator and an external fuel tank. It shows the 12V DC power cable connection and the fuel hose routing, emphasizing to keep the hose away from the muffler.
GENMAX GMEFP Fuel Pump in operation with generator
Image 5.3: The GENMAX GMEFP fuel pump installed on a GENMAX generator, connected to an external red fuel tank. This setup demonstrates the automatic fuel replenishment system in use.

6. Uputstvo za upotrebu

Once the fuel pump is correctly installed and connected, follow these steps for operation:

  1. Napunite sistem goriva: Before starting the generator, use the primer bulb on the fuel hose to manually draw gasoline from the external tank towards the pump. Squeeze the bulb until it feels firm, indicating fuel has reached the pump.
  2. Pokrenite generator: Start your GENMAX inverter generator according to its own instruction manual.
  3. Activate the Fuel Pump: Locate the switch on the GENMAX GMEFP fuel pump and turn it to the "ON" position. The pump will begin to monitor the fuel level in the generator's tank.
  4. Automatic Refueling: When the generator's fuel level drops to a predetermined low point, the GMEFP pump will automatically activate and transfer fuel from the external tank to the generator's tank.
  5. Overfill Protection: The pump's internal fault detection system will automatically stop the fuel transfer once the generator's tank is full, preventing overfilling and ensuring safe operation.
  6. Kontinuirani rad: The pump will cycle on and off as needed to maintain the fuel level, allowing for extended, unattended generator operation.

Napomena: If the generator is not a GENMAX model, ensure its fuel tank depth and fuel cap thread are compatible with the pump before use.

7. Održavanje

Regular maintenance ensures the longevity and reliable performance of your GENMAX GMEFP fuel pump.

8. Otkrivanje problema

If you encounter issues with your GENMAX GMEFP fuel pump, refer to the following common troubleshooting steps:

If these steps do not resolve the issue, please contact GENMAX customer support for assistance.

9. Specifikacije

SpecifikacijaDetalj
ModelGM-PUMP
BrandGENMAX
Izvor napajanja12V DC
Način radaAutomatski
Tip gasaBenzin
Materijal tijelaPlastika
Težina artikla3.65 funti (1.66 kilograma)
Vrsta montažeTank Mount
Applicable Generator Power2kW to 5kW (GENMAX inverter generators)
Compatible External Tank Capacity5-17 Gallons (tank not included)
Required Tank Port Depth> 3.74 inča
Required Tank Port Diameter2.17 inča
Required Tank Port Thread Pitch~ 0.18 inches

10. Garancija i podrška

The GENMAX GMEFP fuel pump comes with a 1 godine garancije od datuma kupovine.

GENMAX also provides BESPLATNA doživotna tehnička podrška from experienced experts. If you have any questions, require assistance with installation, operation, or troubleshooting, please do not hesitate to contact GENMAX customer support.

For warranty claims or technical support, please refer to the contact information provided on the GENMAX official webweb-stranicu ili materijale za registraciju vašeg proizvoda.