Duluth Forge DLS-18T-1

Duluth Forge DLS-18T-1 set za kamin bez ventilacije na dva goriva - uputstvo za upotrebu

Model: DLS-18T-1

1. Uvod

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Duluth Forge DLS-18T-1 Dual Fuel Ventless Fireplace Logs Set. Please read all instructions carefully before installation and use. Retain this manual for future reference.

Duluth Forge DLS-18T-1 Dual Fuel Ventless Fireplace Logs Set with flames

Image 1.1: The Duluth Forge DLS-18T-1 Dual Fuel Ventless Fireplace Logs Set in operation.

2. Sigurnosne informacije

UPOZORENJE: Nepravilna instalacija, podešavanje, izmjena, servisiranje ili održavanje mogu uzrokovati ozljede ili materijalnu štetu. Pogledajte ovaj priručnik. Za pomoć ili dodatne informacije obratite se kvalificiranom instalateru, servisnoj agenciji ili dobavljaču plina.

  • Ovaj uređaj je samo za upotrebu u zatvorenom prostoru.
  • Nemojte skladištiti niti koristiti benzin ili druge zapaljive pare i tekućine u blizini ovog ili bilo kojeg drugog uređaja.
  • The Oxygen Depletion Sensor (ODS) is a safety feature that automatically shuts off the gas supply if oxygen levels in the room fall below a safe threshold. Do not tamper with or bypass the ODS.
  • Ensure adequate ventilation as specified in local codes and this manual.
  • Minimalna potrebna veličina ložišta: 20” V x 29” Š sprijeda (22” Š pozadi) x 13” D.
  • Držite djecu i kućne ljubimce dalje od uređaja dok je u upotrebi.

3. Značajke proizvoda

  • Tehnologija dvostrukog goriva: Operates with either Natural Gas or Liquid Propane.
  • Visoka toplotna snaga: 30,000 BTU, sposoban za grijanje do 1,000 kvadratnih stopa (oko 1350 kvadratnih stopa).
  • Ventless Design: 99.9% efficient, no outside duct or chimney required.
  • Kontrola termostata: Automatically cycles the burner to maintain a desired room temperature.
  • Realistični zapisi: 8 hand-painted ceramic logs designed to emulate a split red oak wood fire.
  • Sigurnosno osiguranje: Equipped with a Safety Pilot O.D.S. (Oxygen Depletion Sensor) with automatic shut-off.
  • Lako paljenje: Battery-assisted Piezo ignition (requires 1 AAA Battery, included).
Close-up of the Duluth Forge gas logs with active flames

Slika 3.1: Detaljno view of the ceramic logs and flames.

4. Sadržaj paketa

Prilikom raspakivanja, provjerite da li su prisutne sve sljedeće komponente:

  • Sklop plinskog plamenika
  • 8 ručno oslikanih keramičkih trupaca
  • Iron Grate
  • U-Burner Chassis
  • Kontrolna jedinica termostata
  • Oxygen Depletion Sensor (integrated)
  • 1 AAA baterije
  • Hardverski paket
Diagram showing all included components of the fireplace log set

Image 4.1: All components included in the Duluth Forge DLS-18T-1 package.

5. Instalacija i podešavanje

Installation should be performed by a qualified professional in accordance with all local codes and the provided instructions. This appliance must be installed in a masonry or agency-approved firebox.

5.1 Provjere prije instalacije

  • Verify that the firebox meets the minimum size requirements: 20” H x 29” W in front (22” W at rear) x 13” D.
  • Ensure the gas supply type (Natural Gas or Liquid Propane) matches the appliance’s configuration. The patented Dual Fuel Technology allows conversion, but it must be correctly set for your gas type.
  • Confirm that the area has adequate ventilation.

5.2 Postavljanje komponenti

  1. Carefully place the burner assembly and iron grate within the firebox.
  2. Arrange the ceramic logs according to the detailed log placement instructions provided with the hardware pack. Proper log placement is crucial for flame appearance and safe operation.
  3. Connect the gas line to the burner assembly. This step requires professional expertise.
Duluth Forge gas logs installed in a fireplace

Image 5.1: The gas log set properly installed within a fireplace.

6. Uputstvo za upotrebu

6.1 Initial Ignition

  1. Provjerite je li ventil za dovod plina otvoren.
  2. Insert the included AAA battery into the Piezo ignition unit.
  3. Turn the control knob to the 'Pilot' position and depress it.
  4. While holding the knob down, press the Piezo ignitor button repeatedly until the pilot flame ignites. Continue to hold the control knob down for approximately 30-60 seconds after ignition to allow the thermocouple to heat up.
  5. Release the control knob. If the pilot flame extinguishes, repeat the process.

6.2 Main Burner Operation (Thermostat Control)

The thermostat control allows you to set a desired room temperature, and the unit will automatically cycle on and off to maintain it.

  1. Once the pilot is lit, turn the control knob from 'Pilot' to the desired heat setting (1-5).
  2. The main burner will ignite, and flames will appear among the logs.
  3. To adjust the temperature, rotate the control knob to a higher or lower setting. The unit will automatically regulate the flame to reach and maintain the set temperature.
  4. To turn off the main burner while keeping the pilot lit, turn the control knob to the 'Pilot' position.
  5. To completely turn off the unit, turn the control knob to the 'Off' position and close the main gas supply valve.
Close-up of the thermostat control knob and Piezo ignitor button

Image 6.1: Thermostat control and Piezo ignition for the log set.

7. Održavanje

Regular maintenance ensures safe and efficient operation of your fireplace logs set.

  • Godišnja inspekcija: Have a qualified service technician inspect the burner assembly, gas connections, and logs annually.
  • čišćenje: Keep the area around the appliance clear of combustible materials. Periodically clean the logs and burner area with a soft brush or vacuum cleaner to remove dust and debris. Ensure the unit is completely cool and the gas supply is off before cleaning.
  • Stanje zapisnika: Inspect logs for cracks or damage. Replace any damaged logs to maintain proper flame patterns and safety.

8. Otkrivanje problema

If you encounter issues, refer to the following common troubleshooting steps. For persistent problems, contact a qualified service technician.

8.1 Pilot Light Will Not Stay Lit

  • Snabdijevanje plinom: Ensure the main gas supply valve is fully open.
  • termopar: The thermocouple may not be heating sufficiently. Ensure the pilot flame is directly impinging on the thermocouple. Hold the control knob down for the recommended 30-60 seconds after ignition.
  • ODS Activation: The Oxygen Depletion Sensor may have activated due to low oxygen levels. Ensure adequate ventilation in the room.
  • Pilot Orifice: A clogged pilot orifice can cause a weak pilot flame. This requires professional cleaning.

8.2 Main Burner Does Not Ignite

  • Pilot Lit: Confirm the pilot light is actively burning. The main burner will not ignite if the pilot is out.
  • Control Knob Position: Ensure the control knob is turned to a numbered heat setting (1-5) and not just 'Pilot' or 'Off'.
  • Pritisak plina: Low gas pressure can prevent the main burner from igniting. Consult your gas supplier or a professional.

9. Specifikacije

AtributDetalj
BrandDuluth Forge
Naziv modelaDualno gorivo
Broj modela stavkeDLS-18T-1-AZ
Izvor napajanjaNa plin (prirodni plin ili tekući propan)
Izlaz toplote30,000 britanskih termalnih jedinica (BTU)
Pokrivenost grijanjaDo 1,000 kvadratnih stopa
Tip ventilacijeVent Free
Dimenzije proizvoda23.5"D x 15.5"Š x 18"H
Minimalna veličina ložišta20” H x 29” W in front (22” W at rear) x 13” D
MaterijalKeramika
Tip paljenjaBattery-assisted Piezo (1 AAA Battery)
Sigurnosne karakteristikeSenzor za smanjenje kisika (ODS)
Težina artikla23.9 funti (10.84 kilograma)
Diagram illustrating the dimensions of the fireplace log set

Image 9.1: Key dimensions of the Duluth Forge DLS-18T-1 log set.

10. Garancija i podrška

For warranty information and customer support, please refer to the documentation included with your product or contact Duluth Forge directly. You can also visit the official Duluth Forge store on Amazon for more information: Duluth Forge Amazon Store.

Povezani dokumenti - DLS-18T-1

Preview Duluth Forge FDLR24/30-1 Priručnik za upotrebu i instalaciju šasije za drva s dvostrukim gorivom i bez ventilacije
Ovaj sveobuhvatni priručnik pruža detaljne upute za rad i instalaciju Duluth Forge FDLR24/30-1 šasije za drva s dva goriva i bez ventilacije. Obuhvata sigurnosne mjere, specifikacije, postupke instalacije, upute za upotrebu, rješavanje problema, zamjenu dijelova i informacije o garanciji.
Preview Upute za ugradnju ventiliranog prirodnog plinskog trupca u Duluth Forgeu
Sveobuhvatni vodič za instalaciju ventiliranih setova trupaca na prirodni plin marke Duluth Forge, modeli FNL18L103B, FN24L103B i FN30L103B. Obuhvata sigurnost, postavljanje trupaca, rad, sušenje i dijelove. Odobreno prema standardima ANSI Z21.11.2 i Z21.60.
Preview Duluth Forge ventilirane lonce prirodnog plina: Priručnik za instalaciju, upotrebu i sigurnost
Sveobuhvatni vodič za ventilirane plinske lonce Duluth Forge (modeli FNVL18-1, FNVL24-1, FNVL30-1). Uključuje upute za instalaciju, postupke rada, sigurnosna upozorenja, savjete za održavanje, rješavanje problema, popise dijelova i informacije o garanciji.
Preview Upute za instalaciju plinskih trupaca Duluth Forge FVFLC22-1 bez ventilacije
Upute za instalaciju Duluth Forge FVFLC22-1 klastera za ogrjev plina bez ventilacije, uključujući sigurnosne smjernice, pravilno postavljanje cjepanica i savjete za upotrebu. Kompatibilno sa kućištima plamenika FLM24-1-LP, FLM24-1-NG, FLT24-1-LP, FLT24-1-NG i FDLT24-1.
Preview Upute za ugradnju i garancija plinskih trupaca bez ventilacije u Duluth Forgeu
Detaljan vodič za instalaciju, popis dijelova i informacije o garanciji za Duluth Forge Vent-Free plinske lonce modeli FVFLC24-1, FVFLC24-2, FVFLC30-1 i FVFLC30-2. Pokriva postavljanje lonca, materijal žara i uvjete garancije za proizvod od Factory Buys Direct.
Preview Duluth Forge FDLR18-1 Uputstvo za upotrebu i instalaciju kućišta za plinsko ogrjevno drvo bez ventilacije
Sveobuhvatni vodič za Duluth Forge FDLR18-1 Vent-Free plinsku šasiju za drva, koji pokriva sigurnost, specifikacije, instalaciju, rad, održavanje i rješavanje problema.