1. Uvod
This manual provides comprehensive instructions for the Power Probe Professional Electrical Test Kit. This kit is designed for automotive electrical testing and repair, featuring the Power Probe 3, a Digital Multimeter, and an Auto AC Temperature Testing Kit. It is suitable for various automotive applications, including gas-powered, hybrid, and electric vehicles.
Komplet uključuje:
- Power Probe 3 for diagnosing automotive circuit issues.
- Digital Multimeter for inspecting multiple electrical readings.
- Auto AC Temperature Testing Kit for evaluating vehicle AC system performance.
- Various accessories to support testing.

Slika 1.1: The complete Power Probe Professional Electrical Test Kit, including the Power Probe 3, Digital Multimeter, and Auto AC Temperature Testing Kit, neatly organized within its durable red carrying case.

Slika 1.2: Gotovoview of the kit's contents, showing the Power Probe 3, Digital Multimeter, temperature sensors, various leads, clips, and probes, all arranged within the open carrying case.
2. Sigurnosne informacije
Always observe the following safety precautions when using the Power Probe Professional Electrical Test Kit:
- Nosite odgovarajuću ličnu zaštitnu opremu, uključujući zaštitne naočale.
- Ensure the vehicle's ignition is off and the parking brake is engaged before performing electrical tests, unless specific instructions require otherwise.
- Avoid contact with live electrical circuits.
- Do not use the tools if they appear damaged.
- Refer to the vehicle manufacturer's service manual for specific electrical system diagrams and procedures.
- Držite djecu i neovlašteno osoblje podalje od radnog područja.
3. Podešavanje
3.1. Power Probe 3
- Instalacija baterije: The Power Probe 3 is typically powered by the vehicle's battery. Connect the red lead to the positive (+) terminal and the black lead to the negative (-) terminal of the vehicle battery.
- Priključak za vrh sonde: Ensure the probe tip is securely attached to the Power Probe 3 unit.
3.2. Digital Multimeter
- Instalacija baterije: Open the battery compartment (usually on the back) and insert the required batteries, observing polarity.
- Lead Connection: Connect the black test lead to the "COM" (common) jack. Connect the red test lead to the appropriate jack for the measurement type (e.g., "VΩmA" for voltage, resistance, or current).
3.3. Auto AC Temperature Testing Kit
- Instalacija baterije: Install batteries into the main display unit and each wireless temperature sensor, ensuring correct polarity.
- Položaj senzora: Place the wireless temperature sensors into the vehicle's AC vents or other desired measurement locations.
- Uključeno: Turn on the main display unit and each sensor. The display unit should automatically connect to the sensors.
4. Uputstvo za upotrebu
4.1. Using the Power Probe 3
The Power Probe 3 is used to apply power or ground to components and test for voltage and continuity.
- Voltage Testiranje: Touch the probe tip to the circuit or component. The LCD screen will display the voltage. Red/Green lights indicate positive/negative polarity.
- Applying Power/Ground: Use the rocker switch to apply battery voltage or ground to a component for functional testing. Exercise caution to avoid short circuits.
- Testiranje kontinuiteta: Connect the auxiliary ground lead to a known good ground. Touch the probe tip to the component. The LCD will indicate continuity.

Slika 4.1: A Power Probe 3 being used to test an automotive fuse box. The probe tip is inserted into a fuse slot, and the LCD screen displays the voltage reading, while the red and black leads are connected to the vehicle's battery.
4.2. Using the Digital Multimeter
The Digital Multimeter can measure various electrical parameters.
- Voltage (DC/AC): Okrenite okretni prekidač na željenu jačinu zvukatage range (DCV or ACV). Connect the test leads in parallel with the circuit or component.
- Otpor (Ω): Turn the rotary switch to the Ω (ohms) range. Ensure the circuit is de-energized. Connect the test leads across the component.
- Struja (A): Turn the rotary switch to the desired current range (DCA or ACA). Connect the multimeter in series with the circuit. Oprez: Incorrect connection can damage the multimeter or vehicle.
- kontinuitet: Turn the rotary switch to the continuity setting (often indicated by a speaker icon). A beep indicates continuity.
- Ostale funkcije: Refer to the multimeter's specific markings for frequency, temperature, and capacitance measurements.

Slika 4.2: The Digital Multimeter displaying a voltage reading while connected to a car battery. The red and black test leads are attached to the positive and negative terminals of the battery, respectively.
4.3. Using the Auto AC Temperature Testing Kit
This kit provides wireless temperature readings to assess AC system performance.
- Položaj senzora: Insert the wireless temperature sensors into the vehicle's AC vents. The kit supports dual-zone readings.
- Praćenje očitavanja: The main display unit will show real-time temperature readings from the connected sensors.
- Raspon: Sensors can transmit readings from up to 16.5 feet away.

Slika 4.3: A wireless temperature sensor from the Auto AC Temperature Testing Kit inserted into a car's air conditioning vent, displaying a temperature reading on its screen.

Slika 4.4: The main display unit of the Auto AC Temperature Testing Kit positioned on a car dashboard, showing dual temperature readings. Two wireless sensors are visible, one placed in an AC vent and another held by a hand, demonstrating multi-point temperature monitoring.
5. Održavanje
- čišćenje: Wipe down all tools with a clean, dry cloth after each use. Do not use abrasive cleaners or solvents.
- Skladištenje: Store the kit in its original carrying case in a dry, cool place, away from direct sunlight and extreme temperatures.
- Zamjena baterije: Replace batteries in the Digital Multimeter and Auto AC Temperature Testing Kit components as needed. Refer to the individual component manuals for specific battery types and replacement procedures.
- Lead Inspection: Regularly inspect test leads and probes for signs of wear, cuts, or damage. Replace damaged leads immediately to ensure safety and accurate readings.
6. Otkrivanje problema
| Problem | Mogući uzrok | Rješenje |
|---|---|---|
| Power Probe 3 not powering on. | Incorrect connection to vehicle battery; vehicle battery is dead. | Ensure red lead is connected to positive (+) and black lead to negative (-) terminals. Check vehicle battery charge. |
| Multimeter displays "OL" or no reading. | Incorrect range selected; dead batteries; open circuit. | Select appropriate range. Replace multimeter batteries. Check for breaks in the circuit being tested. |
| AC Temp Kit sensors not connecting. | Dead sensor batteries; sensors out of range; interference. | Replace sensor batteries. Move sensors closer to the main unit. Reduce potential sources of wireless interference. |
| Netačna očitavanja. | Damaged leads/probes; incorrect measurement technique; environmental factors. | Inspect and replace damaged leads. Review operating instructions for correct technique. Ensure stable testing environment. |
7. Specifikacije
- Brand: Power Probe
- Model: Power Probe 3-Piece Electrical and AC Auto Testing Kit
- Izvor napajanja: Battery Powered (for Multimeter and Temp Kit); Vehicle Battery Powered (for Power Probe 3)
- Vrsta mjerenja: Multimetar (Voltage, Resistance, Current, Continuity, Frequency, Temperature, Capacitance)
- Power Probe 3 Features: LCD screen, Red/Green polarity indicators, apply power/ground.
- AC Temp Kit Features: Wireless, dual-zone readings, up to 16.5 ft range.
- ASIN: B0C883M82M
- Datum prve dostupnosti: 16. juna 2023
8. Garancija i podrška
For warranty information and technical support, please refer to the documentation included with your purchase or visit the official Power Probe webSačuvajte dokaz o kupovini za slučaj reklamacije.
For additional assistance, you may contact Power Probe customer service through their official channels.