1. Uvod

This user manual provides comprehensive instructions for the installation, operation, and maintenance of your ApooDr 9000 BTU Mini Split Air Conditioner. This ductless inverter system offers efficient cooling and heating for spaces up to 400 sq ft, featuring a 17 SEER2 rating and 110V operation. Please read this manual thoroughly before using the appliance to ensure safe and optimal performance.

ApooDr 9000 BTU Mini Split Air Conditioner with indoor unit, outdoor unit, remote, and installation kit

Figure 1: ApooDr 9000 BTU Mini Split Air Conditioner system components.

2. Značajke proizvoda

ApooDr Mini Split Air Conditioner highlighting cooling, heating, quiet operation, and energy efficiency

Figure 2: Key features of the ApooDr Mini Split Air Conditioner.

3. Šta se nalazi u kutiji

Your ApooDr Mini Split Air Conditioner package includes the following components:

Components included in the ApooDr Mini Split Air Conditioner package: indoor unit, outdoor unit, communication wires, pre-flared insulated copper line set, and remote.

Figure 3: All components included for installation.

4. Postavljanje i instalacija

Professional installation is required for this mini split system. For detailed step-by-step instructions, please refer to the official Uputstvo za instalaciju (PDF). Key steps generally include:

  1. Montiranje unutrašnje jedinice: Select an appropriate location on an interior wall, ensuring proper clearance for air circulation and drainage.
  2. Montiranje vanjske jedinice: Choose a stable, level surface outdoors, away from obstructions and direct sunlight.
  3. Spajanje rashladnih vodova: Connect the pre-charged copper line set between the indoor and outdoor units. Ensure proper flaring and tightening to prevent leaks.
  4. Električno ožičenje: Connect the communication wire and power supply according to the wiring diagram in the manual. This unit operates on 110V/60Hz.
  5. Usisavanje sistema: A vacuum pump is required to remove air and moisture from the refrigerant lines before releasing the pre-charged R-410A refrigerant.
  6. Odvodni priključak: Install the condensate drain line from the indoor unit to ensure proper water removal.
Diagram showing indoor unit, outdoor unit, communication wires, pre-flared insulated copper line set, backlit remote, and washable filter, indicating easy installation.

Slika 4: Gotovoview of components for installation.

5. Uputstvo za upotrebu

The ApooDr Mini Split Air Conditioner is controlled via the included backlit LCD remote. The indoor unit features an LED display showing the current temperature.

5.1 Funkcije daljinskog upravljača

ApooDr Mini Split Air Conditioner remote control with LCD display and various buttons for mode, fan, temperature, timer, sleep, swing, and more.

Figure 5: Backlit LCD Remote Control.

Indoor unit displaying cool and heat capabilities with 5 operating modes: Auto, Cool, Dry, Heat, Fan.

Figure 6: The 5 versatile operating modes.

6. Održavanje

Regular maintenance ensures the longevity and efficiency of your mini split system. The indoor unit features a washable air filter for easy cleaning.

6.1 Čišćenje vazdušnog filtera

The air filter should be cleaned regularly, typically every two weeks, or more frequently depending on usage and air quality.

  1. Iskljuciti: Uvjerite se da je jedinica isključena i isključena iz struje prije čišćenja.
  2. Otvorite prednju ploču: Pažljivo podignite prednju ploču unutrašnje jedinice.
  3. Ukloni filtere: Pažljivo izvucite filtere za zrak.
  4. Očistite filtere: Wash the filters with lukewarm water and a mild detergent. Rinse thoroughly and allow them to air dry completely before reinstallation. Do not use hot water or harsh chemicals.
  5. Ponovna instalacija filtera: Slide the dry filters back into their slots and close the front panel.
Close-up of the washable and easy-to-clean air filter of the indoor unit.

Figure 7: The washable air filter for easy maintenance.

6.2 Generalno čišćenje

Obrišite spoljašnjost unutrašnje i spoljne jedinice mekom,amp tkanina. Nemojte koristiti abrazivna sredstva za čišćenje ili rastvarače.

7. Otkrivanje problema

If you encounter any issues with your ApooDr Mini Split Air Conditioner, please refer to the comprehensive Vodič za rješavanje problema (PDF) for solutions to common problems. The unit also features a Self Diagnosis function to help identify potential issues.

Uobičajeni problemi i rješenja:

ProblemMogući uzrokRješenje
Jedinica se ne uključuje.Nema napajanja, baterije daljinskog upravljača su prazne, osigurač je isključen.Provjerite napajanje, zamijenite baterije daljinskog upravljača, resetirajte osigurač.
Nedovoljno hlađenje/grijanje.Dirty air filter, blocked outdoor unit, incorrect mode/temperature setting.Clean air filter, clear obstructions from outdoor unit, verify settings.
Neobična buka.Loose parts, foreign objects, refrigerant issues.Inspect unit for loose components, remove foreign objects. If noise persists, contact professional service.
Curenje vode iz unutrašnje jedinice.Začepljena odvodna cijev, nepravilna instalacija.Clear drain pipe. If issue persists, professional inspection is needed.

8. Specifikacije

Detailed technical specifications for the ApooDr 9000 BTU Mini Split Air Conditioner (Model: ASF16-09H3B):

SpecifikacijaVrijednost
Brand NameApooDr
Informacije o modeluASF16-09H3B
Težina artikla80 funte
Dimenzije proizvoda7.64 x 28.15 x 11.22 inča
Zemlja porijeklaKina
Efikasnost (SEER)16.5
Kapacitet9000 BTU (Cooling Power) / 9000 Cubic Feet (Air Volume)
Godišnja potrošnja energije890 Watts
Nivo buke27.5 dB
Vrsta instalacijeSplit sistem
Form FactorMini-Split
Posebne karakteristikeInverter Compressor
BojaBijelo
Voltage110 Volts
Wattage890 vati
Uključene komponenteRemote, Copper line set, Communication wire
Pokrivenost poda400 kvadratnih stopa
EnergyGuide label for ApooDr Mini Split Air Conditioner showing 16.50 SEER and 9.80 HSPF ratings.

Figure 8: EnergyGuide rating for the system.

9. Garancija i podrška

ApooDr provides the following warranty for this product:

For warranty claims or technical support, please contact the seller, ApooDr, directly. Professional installation is required to maintain warranty validity.

Povezani dokumenti - ASF16-09H3B

Preview Uputstvo za upotrebu i instalaciju klima uređaja ApooDr ASF16 serije
Sveobuhvatni vodič za klima uređaje serije ApooDr ASF16, koji obuhvata informacije za vlasnika, postupke instalacije, održavanje, rješavanje problema i specifikacije. Naučite kako sigurno instalirati i koristiti svoj ApooDr klima uređaj.
Preview ApooDr Split-Type klima uređaj za upotrebu i uputstvo za instalaciju
Sveobuhvatni vodič za ApooDr klima uređaje split tipa, koji obuhvata sigurnosne mjere opreza, specifikacije uređaja, karakteristike, njegu i održavanje, rješavanje problema, pribor i detaljne postupke instalacije za unutrašnje i vanjske jedinice. Uključuje spajanje cijevi za rashladno sredstvo, odvod zraka, električne provjere i upute za probni rad.
Preview Uputstvo za upotrebu ApooDr split klima uređaja
Ovaj priručnik s uputama pruža bitne informacije i preporuke za pravilnu instalaciju, rad i održavanje ApooDr Split klima uređaja kako bi se osigurale optimalne performanse i dugotrajnost.
Preview Izjava o ograničenoj garanciji za ApooDr split sistem toplotne pumpe sa kanalima
Zvanična izjava o ograničenoj garanciji za ApooDr split sisteme sa kanalnim toplotnim pumpama, u kojoj se detaljno opisuju pokrivenost, ograničenja i uslovi za registraciju proizvoda.
Preview Vodič za dimenzije klima uređaja serije ApooDr AHU3G-24HFN-AB
Detaljne dimenzijske specifikacije u inčima za klima uređaje serije ApooDr AHU3G-24HFN-AB, uključujući unutrašnje i vanjske komponente. Relevantno za modele AHU3G-24HFN-AB-50FT, AHU3G-24HFN-AB-25FT i CAC-24k.
Preview Servisni priručnik za ApooDr AHU 3. generacije 3D inverterske serije klima uređaja
Servisni priručnik za ApooDr AHU 3. generacije 3D inverterskih klima uređaja, koji pokriva instalaciju, rad, rješavanje problema i sigurnosne mjere za modele od AHU3G-24HFN-A do AHU3G-60HFN-A.