Einhell GE-DP 900

Einhell GE-DP 900 Cut Dirty Water Pump Instruction Manual

Model: GE-DP 900 | Brand: Einhell

1. Uvod

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Einhell GE-DP 900 Cut Dirty Water Pump. Please read these instructions carefully before using the pump for the first time. Keep this manual in a safe place for future reference.

The Einhell GE-DP 900 is a powerful dirty water pump designed for pumping water with a high percentage of foreign bodies. It is suitable for applications such as draining basements, excavations, ponds, rain barrels, and wells. The integrated cutting mechanism allows for shredding of solid particles, enhancing its utility in highly contaminated water.

2. Sigurnosna uputstva

UPOZORENJE: Always disconnect the pump from the power supply before performing any maintenance, cleaning, or adjustments. Failure to do so can result in serious injury or death.

  • Osigurajte napajanje voltage odgovara nazivnoj snazi ​​na natpisnoj pločici pumpe.
  • Ne koristite pumpu ako je kabel za napajanje ili utikač oštećen.
  • Nikada ne podižite ili nosite pumpu držeći je za njen kabel za napajanje.
  • Držite djecu i neovlaštene osobe dalje od pumpe koja radi.
  • Do not use the pump for flammable, explosive, or corrosive liquids.
  • Ensure adequate ventilation if operating in confined spaces.
  • Always use a residual current device (RCD) with a tripping current not exceeding 30 mA.
  • Zaštitite pumpu od smrzavanja.

3. Proizvod je gotovview

The Einhell GE-DP 900 is constructed with a robust cast aluminum and cast iron housing for durability. Key components include the motor, pump housing, float switch, and hose connection.

Einhell GE-DP 900 Cut Dirty Water Pump

Slika 3.1: Gotovoview of the Einhell GE-DP 900 Cut Dirty Water Pump. This image shows the complete pump unit, highlighting its red and black casing, integrated float switch, and hose connection port.

Close-up of Einhell GE-DP 900 pump with float switch

Slika 3.2: Close-up view of the pump's main body and the float switch. The float switch is crucial for automatic operation, turning the pump on and off based on water levels.

Hose connection on Einhell GE-DP 900 pump

Slika 3.3: Detail of the 2-inch hose connection. This connection allows for the attachment of large diameter hoses, facilitating efficient water discharge.

Cutting mechanism at the base of Einhell GE-DP 900 pump

Slika 3.4: View of the integrated cutting mechanism located at the base of the pump. This mechanism is designed to shred solid particles up to 35 mm in diameter, preventing blockages.

4. Podešavanje

  1. Raspakivanje: Carefully remove the pump and all accessories from the packaging. Inspect for any damage during transit.
  2. Priključak crijeva: Attach a suitable discharge hose to the 2-inch connector on the pump. Ensure the connection is secure to prevent leaks during operation.
  3. Pozicioniranje: Place the pump on a stable, level surface in the water to be pumped. Ensure the pump is fully submerged if operating in automatic mode with the float switch. The maximum immersion depth is 7 meters.
  4. Podešavanje plovnog prekidača: The float switch controls the automatic on/off function. Adjust its position to set the desired minimum and maximum water levels for operation. The pump will start when the water level rises and lift the float switch, and stop when the water level drops and the float switch falls.
  5. Priključak za napajanje: Connect the power cable to a grounded electrical outlet (230V AC) protected by a residual current device (RCD).

5. Uputstvo za upotrebu

  1. Automatski rad:
    • Ensure the float switch is freely movable and adjusted to the desired water levels.
    • Plug the pump into the power supply. The pump will start automatically when the water level reaches the upper activation point of the float switch.
    • The pump will stop automatically when the water level drops to the lower deactivation point of the float switch.
  2. Ručni rad:

    For continuous operation, some models allow the float switch to be secured in an upward position. Refer to the specific markings or instructions on your pump for manual mode. In manual mode, the pump will run continuously until unplugged or the water level drops below the pump's intake.

  3. Nadgledanje: During operation, periodically check the pump for unusual noises or vibrations. Ensure the discharge hose is not kinked or blocked.
  4. Gašenje: To stop the pump, disconnect it from the power supply. If operating in automatic mode, it will stop when the water level drops.
Man operating Einhell GE-DP 900 pump in a muddy pond

Slika 5.1: An individual demonstrating the use of the Einhell GE-DP 900 pump in a muddy water environment. This illustrates a typical application for dirty water removal.

6. Održavanje

Redovno održavanje osigurava dugotrajnost i optimalne performanse vaše pumpe. Uvijek isključite pumpu iz napajanja prije bilo kakvog održavanja.

  • čišćenje: After each use, especially with dirty water, rinse the pump thoroughly with clean water. Remove any debris or foreign objects from the intake screen and cutting mechanism.
  • inspekcija: Periodically inspect the power cable, plug, and float switch for any signs of damage or wear. Check the hose connections for tightness.
  • Zaštita od smrzavanja: If the pump is stored in an area where temperatures may drop below freezing, ensure all water is drained from the pump to prevent damage.
  • Skladištenje: Store the pump in a dry, frost-free location when not in use.

7. Otkrivanje problema

Ovaj odjeljak se bavi uobičajenim problemima na koje možete naići. Za probleme koji nisu ovdje navedeni, obratite se korisničkoj podršci.

ProblemMogući uzrokRješenje
Pumpa se ne pokreće.No power supply; float switch not activated; motor overload protection triggered.Check power connection and circuit breaker; adjust float switch position; allow motor to cool down.
Pumpa radi, ali voda se ne ispušta.Intake blocked; discharge hose kinked or blocked; airlock in pump.Clean intake screen; clear discharge hose; submerge pump fully and shake gently to release air.
Reduced pumping capacity.Partial blockage; worn impeller (unlikely for new pump).Clean intake and cutting mechanism; ensure hose is clear.
Pumpa se neočekivano zaustavlja.Float switch deactivated; motor overload protection triggered.Check water level and float switch position; allow motor to cool.

8. Tehničke specifikacije

FeatureSpecifikacija
BrandEinhell
Broj modela4181550
Izvor napajanjaAC
Voltage230 Volts
Snaga (motor)900 Watts
Maksimalni protok16,000 litara na sat
Maksimalna visina podizanja11.5 meters (393.7 Inches)
Maximum Immersion Depth7 metara
Max. Veličina čestica35 mm
Dimenzije proizvoda (D x Š x V)10.83" x 8.78" x 16.54"
Težina artikla12.8 kilograma (28.2 funti)
MaterijalAluminum, Cast Iron
Posebne karakteristikeIntegrated Cutting Mechanism, Adjustable Float Switch

9. Garancija i podrška

Einhell products are manufactured with quality and durability in mind. For warranty information, please refer to the warranty card included with your purchase or visit the official Einhell website.

For technical support, spare parts, or service inquiries, please contact Einhell customer service. Contact details can typically be found on the Einhell webweb-mjestu ili u dokumentaciji vašeg proizvoda.

Trajanje dostupnosti rezervnih dijelova za EU: 1 Year (as per product specifications).

Povezani dokumenti - GE-DP 900

Preview Einhell GE-DP 7535 N LL ECO Schmutzwasserpumpe / Flutset Bedienungsanleitung
Diese Anleitung beschreibt die Bedienung und Wartung der Einhell GE-DP 7535 N LL ECO Schmutzwasserpumpe und des Flutsets. Sie enthält wichtige Sicherheitshinweise, technische Daten und Anleitungen zur Fehlerbehebung für den effizienten Einsatz der Pumpe.
Preview Einhell GC-DP 3325 Schmutzwasserpumpe Bedienungsanleitung
Original betriebsanleitung für die Einhell GC-DP 3325 Schmutzwasserpumpe. Enthält wichtige Sicherheitshinweise, Installationsanleitungen, Bedienung und Wartung.
Preview Einhell GE-CF 18/2200 Li bežični ventilator - uputstvo za upotrebu
Otkrijte Einhell GE-CF 18/2200 Li bežični ventilator. Ovo uputstvo za upotrebu detaljno opisuje njegove karakteristike za ventilaciju domaćinstva, uključujući bežično napajanje, podesive brzine i prenosivost. Saznajte više o sigurnom radu, održavanju i garanciji.
Preview Einhell TC-RH 900 Bohrhammer Bedienungsanleitung
Dieses Dokument enthält eine umfassende Bedienungsanleitung, Sicherheitshinweise, technische Daten und Wartunginformationen za Einhell TC-RH 900 Bohrhammer. Unverzichtbar für die sichere und effektive Nutzung des Elektrowerkzeugs.
Preview Einhell GE-SP 18 Li Akku-Klarwasserpumpe Bedienungsanleitung
Die offizielle Bedienungsanleitung für die Einhell GE-SP 18 Li Akku-Klarwasserpumpe. Enthält detaillierte Informationen zu Sicherheit, Installation, Betrieb, Wartung und Fehlerbehebung für dieses leistungsstarke Gartengerät.
Preview Einhell TC-RH 900 Bohrhammer Bedienungsanleitung
Umfassende Bedienungsanleitung und Sicherheitshinweise za Einhell TC-RH 900 Bohrhammer. Enthält technische Daten, Bedienungsanleitungen, Wartungs- und Garantieinformationen.