This manual provides essential information for the proper installation, operation, and maintenance of the Simplex 4100-9610 Remote Annunciator. The 4100-9610 is designed to provide remote indication and control capabilities for compatible Simplex fire alarm control panels. Please read this manual thoroughly before attempting any installation or operation.
2. Sigurnosne informacije
Uvijek se pridržavajte sljedećih sigurnosnih mjera opreza kako biste spriječili ozljede i oštećenje opreme:
- Instalaciju i servisiranje mora obavljati isključivo kvalificirano osoblje.
- Disconnect all power sources before installing or servicing the annunciator.
- Pridržavajte se svih lokalnih i nacionalnih električnih propisa i propisa.
- Do not operate the annunciator if it appears damaged.
- Osigurajte ispravno uzemljenje kako biste spriječili strujni udar.
- Keep the annunciator away from moisture and extreme temperatures.
This device is part of a fire safety system. Proper functioning is critical for life safety. Regular testing and maintenance are required.
3. Sadržaj paketa
Upon opening the package, verify that all components are present and undamaged. The standard package for the Simplex 4100-9610 Remote Annunciator typically includes:
- Simplex 4100-9610 Remote Annunciator Unit
- Mounting Hardware (screws, anchors, etc. - may vary)
- Installation Guide / Quick Start Guide (this manual provides detailed instructions)

Figure 3.1: Simplex 4100-9610 Remote Annunciator as typically packaged. The image shows the annunciator unit, which consists of a metal enclosure housing circuit boards and connectors, secured within cardboard protective corners and plastic strapping.
Ako bilo koji artikl nedostaje ili je oštećen, odmah se obratite svom dobavljaču.
4. Postavljanje i instalacija
The 4100-9610 Remote Annunciator requires careful installation to ensure proper operation and compliance with safety standards. Refer to the specific wiring diagrams provided with your fire alarm control panel for detailed connection instructions.
4.1 Montaža
- Choose a suitable location for the annunciator, typically near an entrance or a manned station, ensuring visibility and accessibility.
- Ensure the mounting surface is flat and capable of supporting the annunciator's weight.
- Mark the mounting holes on the wall using the annunciator's enclosure as a template.
- Drill pilot holes and install appropriate wall anchors if necessary.
- Secure the annunciator to the wall using the provided mounting hardware.
4.2 Ožičenje
All wiring must comply with NFPA 70 (National Electrical Code) and NFPA 72 (National Fire Alarm and Signaling Code), as well as local codes.
- Priključak za napajanje: Connect the annunciator to the designated power source from the fire alarm control panel. Ensure correct polarity. The annunciator is battery powered, likely drawing power from the main panel's battery backup system.
- Communication Bus: Connect the annunciator to the fire alarm control panel's communication bus (e.g., IDNet, MAPNET II) using shielded twisted-pair cable as specified by Simplex.
- uzemljenje: Ensure the annunciator enclosure is properly grounded to the building's protective earth ground.
Napomena: Refer to the specific installation instructions for your Simplex Fire Alarm Control Panel for detailed wiring diagrams and compatibility information.
5. Uputstvo za upotrebu
The Simplex 4100-9610 Remote Annunciator provides visual and audible indications of system status and allows for basic control functions. Specific functions may vary based on the configuration of the connected fire alarm control panel.
5.1 Indikatori statusa
The annunciator typically features various LED indicators to display system status:
- Alarm: Illuminates when a fire alarm condition is detected.
- problem: Illuminates when a system fault or trouble condition occurs.
- Nadzorni: Illuminates for supervisory conditions (e.g., sprinkler valve tamper).
- Snaga: Indicates that primary power is supplied to the system.
5.2 Kontrolne funkcije
Common control buttons on a remote annunciator may include:
- Priznajte: Silences the annunciator's local audible signal and acknowledges new events at the control panel.
- tišina: Silences audible notification appliances (horns, strobes) throughout the system.
- Resetovati: Resets the fire alarm system after an alarm or trouble condition has been cleared.
- Lamp Test: Illuminates all LEDs to verify their functionality.
Važno: Always follow your facility's emergency procedures when responding to alarm conditions.
6. Održavanje
Regular maintenance ensures the continued reliable operation of your Simplex 4100-9610 Remote Annunciator and the overall fire alarm system.
- Vizuelni pregled: Periodically inspect the annunciator for any signs of physical damage, loose connections, or excessive dust accumulation.
- čišćenje: Clean the exterior of the annunciator with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Funkcionalno testiranje: Perform regular functional tests as part of your overall fire alarm system testing schedule, typically monthly or annually, as required by local codes and NFPA 72. This includes verifying LED illumination and button functionality.
- Profesionalni servis: All internal servicing and complex troubleshooting should be performed by certified fire alarm technicians.
7. Otkrivanje problema
Ovaj odjeljak pruža osnovne korake za rješavanje uobičajenih problema. Za složenije probleme obratite se kvalificiranom servisnom tehničaru.
| Problem | Mogući uzrok | Rješenje |
|---|---|---|
| Annunciator is not powered on. | No power from control panel; loose wiring; internal fault. | Verify power supply from the control panel. Check wiring connections. If problem persists, contact service. |
| LEDs not illuminating during lamp test. | Faulty LEDs; internal circuit issue. | Za dijagnostiku i popravku obratite se kvalificiranom serviseru. |
| Audible alarm not silencing. | Acknowledge button not pressed; new alarm condition; system fault. | Press the Acknowledge button. Check for new alarm events. If problem persists, contact service. |
| Annunciator displays "Trouble" light. | System fault detected by the main control panel. | Check the main fire alarm control panel for specific trouble codes. Contact service if unable to resolve. |
8. Specifikacije
The following specifications apply to the Simplex 4100-9610 Remote Annunciator:
- Model: 4100-9610
- Brand: SIMPLEX
- Broj dijela: S41009610
- UPC: 742779297952
- Izvor napajanja: Battery Powered (typically from main FACP)
- Vrsta alarma: Audible (local annunciator sounder)
- Stil: Sigurnost
- Broj stavki: 1 (po jedinici)
- Proizvođač: SIMPLEX
Note: Specifications are subject to change without notice. Refer to the latest product data sheets for the most current information.
9. Informacije o garanciji
Simplex products are typically covered by a limited warranty against defects in materials and workmanship. The specific terms and duration of the warranty may vary based on the region and purchase agreement. Please retain your proof of purchase. For detailed warranty information, contact your authorized Simplex distributor or refer to the warranty statement provided at the time of purchase.
This warranty does not cover damage resulting from improper installation, misuse, unauthorized modification, or acts of nature.
10. Korisnička podrška
For technical assistance, troubleshooting beyond the scope of this manual, or to inquire about replacement parts, please contact your authorized Simplex service provider or the vendor from whom the product was purchased. Ensure you have the model number (4100-9610) and serial number (if applicable) of your annunciator ready when contacting support.
For general inquiries about Simplex products, visit the official Simplex webstranice ili kontaktirajte njihov odjel za korisničku podršku.