Trane CNT07941_v220

Trane CNT07941 Control Circuit Board User Manual

Model: CNT07941_v220

1. Proizvod je gotovview

The Trane CNT07941 Control Circuit Board is an Original Equipment Manufacturer (OEM) component designed for American Standard and Trane HVAC systems. This board serves as a critical control unit, specifically a 1-stage, 120V HSI (Hot Surface Ignition), 1-speed inducer control board without a cover. It is a direct replacement for various older models, including CNT07541, BAF00434, CNT03797, and others.

This circuit board is essential for the proper functioning of compatible gas furnace models, managing ignition sequences and overall system operation. It is important to note that this is a factory OEM component and not a universal replacement, ensuring compatibility and optimal performance with specified Trane and American Standard units.

Trane CNT07941 Control Circuit Board in packaging next to the board itself

Image: The Trane CNT07941 Control Circuit Board, shown both in its original packaging and as a standalone component, highlighting its design and form factor.

2. Sigurnosne informacije

WARNING: Installation and servicing of HVAC components should only be performed by qualified, experienced technicians. Improper installation, adjustment, alteration, service, or maintenance can cause property damage, personal injury, or loss of life. Read and understand these instructions thoroughly before attempting any installation or service.

3. Postavljanje i instalacija

This section provides general guidelines for replacing a furnace control board. Specific steps may vary depending on your furnace model. Always consult your furnace's service manual for detailed instructions.

  1. Isključivanje struje: Turn off all electrical power to the furnace at the main service panel or circuit breaker. Verify power is off using a voltage metar.
  2. Ploča za kontrolu pristupa: Locate and open the furnace's control panel or access door. The control board is typically mounted within this compartment.
  3. Ožičenje dokumenata: Before disconnecting any wires, take clear photographs of the existing wiring connections to the old control board. Label each wire and its corresponding terminal on the old board. This is crucial for correct re-installation.
  4. Odspojite žice: Carefully disconnect all wires from the old control board. Note any specific connectors or harnesses.
  5. Uklonite staru ploču: Unmount the old control board. It may be secured with screws, clips, or standoffs.
  6. Instalirajte novu ploču: Mount the new Trane CNT07941 control board in the same location as the old one, ensuring it is securely fastened.
  7. Povežite ožičenje: Using your documented photographs and labels, carefully connect all wires to the corresponding terminals on the new control board. Double-check every connection for accuracy and tightness.
  8. Sigurna pristupna ploča: Close and secure the furnace's control panel or access door.
  9. Vrati snagu: Restore electrical power to the furnace at the main service panel or circuit breaker.
  10. Probni rad: Initiate a heating cycle to verify proper operation of the furnace. Observe the ignition sequence and fan operation.
Close-up view of the Trane CNT07941 Control Circuit Board, showing various components and connection points.

Slika: Detaljna view of the Trane CNT07941 circuit board, illustrating the layout of its electronic components and terminal blocks for wiring connections.

4. Principi rada

The Trane CNT07941 Control Circuit Board is the central processing unit for your furnace's heating cycle. It receives signals from the thermostat and other safety devices to manage the sequence of operations, including:

The board also incorporates diagnostic features, often indicated by an LED light, to assist in troubleshooting system faults.

5. Održavanje

The Trane CNT07941 control board itself requires minimal maintenance. However, regular maintenance of the overall HVAC system is crucial for its longevity and proper function.

6. Otkrivanje problema

If your furnace is not operating correctly after installing the Trane CNT07941 control board, or if you suspect a board-related issue, consider the following common troubleshooting steps. Always ensure power is disconnected before inspecting or touching internal components.

Uobičajeni scenariji rješavanja problema
SimptomMogući uzrokAkcija
Furnace not starting (no fan, no heat)No power to furnace, thermostat issue, loose wiring, tripped safety switch.Check circuit breaker. Ensure thermostat is set to heat and temperature is above ambient. Verify all wiring connections to the board are secure. Check furnace safety switches (e.g., limit switch, rollout switch).
Inducer motor runs, but no ignitionFaulty igniter, clogged pressure switch hose, gas supply issue, flame sensor dirty/faulty.Check if gas valve is open. Inspect igniter for cracks or damage. Clean flame sensor. Check pressure switch hose for blockages.
Blower fan runs continuouslyThermostat fan setting, stuck fan relay on board, faulty limit switch.Ensure thermostat fan setting is "Auto". If problem persists, professional diagnosis is recommended.
Error code displayed on board LEDSpecifična sistemska greška.Refer to your furnace's service manual for the meaning of the specific flash code and recommended corrective actions.

If troubleshooting steps do not resolve the issue, or if you are uncomfortable performing these checks, it is strongly recommended to contact a certified HVAC technician. Attempting repairs without proper knowledge and tools can be dangerous and may void warranties.

7. Specifikacije

Key specifications for the Trane CNT07941 Control Circuit Board:

Diagram showing the dimensions of the Trane CNT07941 Control Circuit Board, with measurements 4 15/16 inches by 5 15/16 inches.

Image: A technical diagram illustrating the physical dimensions of the Trane CNT07941 circuit board, indicating its length and width for accurate fitment.

Povezani dokumenti - CNT07941_v220

Preview Trane & American Standard IFC Board Failure Service Bulletin - MANDATORY Rework
Official service bulletin from Trane and American Standard regarding Integrated Furnace Control (IFC) board failures in specific furnace models. Details error code 5, affected models, and mandatory rework instructions.
Preview Upute za instalaciju kompleta servisnog programa Trane RTWD/RTUD R'newal
Upute za instalaciju Trane R'newal servisnog kompleta za RTWD i RTUD rashladne uređaje, s detaljnim opisom lokacije dijelova, sigurnosnih upozorenja, ekoloških problema i kvarova komponenti.
Preview Trane sveobuhvatni katalog dizajna sistema za hlađenje vode
Traneov sveobuhvatni katalog za projektovanje naprednih sistema za hlađenje vodom. Ovaj vodič detaljno opisuje komponente sistema, najsavremenije principe projektovanja, konfiguracije i kriterije za odabir hladnjaka, rashladnih tornjeva, pumpi i regulacionih ventila. Fokusira se na postizanje efikasnosti, pouzdanosti i isplativosti u komercijalnim i industrijskim HVAC primjenama, uključujući uvide u Tracer Chiller Plant Control i Trane Design Assist.
Preview Trane AFDR upute za naknadnu ugradnju za RTHD rashladne agregate
Sveobuhvatni vodič za instalaciju Trane AFDR Retrofit Air-cooled Adaptive Frequency Drive™ za RTHD rashladne uređaje. Obuhvata sigurnost, uslove okoline, detalje modela i detaljne postupke instalacije za kvalifikovano osoblje.
Preview Trane Ignitor Upute za instalaciju KIT03033USA
Detaljne upute za instalaciju Trane Ignitor KIT03033USA, koje obuhvataju sigurnosna upozorenja, ekološke aspekte i detaljne postupke za kvalificirano osoblje.
Preview Trane Air-Fi™ Wireless Communications Sensor (WCS) Quick Reference Guide
This guide provides quick reference information for the Trane Air-Fi™ Wireless Communications Sensor (WCS), detailing how to adjust room temperature, system settings, fan speed, manage occupancy, and understand error codes. It includes safety warnings and battery life indicators.