ANKO ANKPS-301-4P

ANKO GFCI utičnica 20 Amp 4 Pack korisnički priručnik

Brand: ANKO | Model: ANKPS-301-4P

1. Sigurnosne informacije

Važna upozorenja

  • To prevent severe shock or electrocution, always turn the power off at the service panel before working with the wiring.
  • Use this GFCI receptacle with copper or copper-clad wire. Nemojte koristiti aluminijumsku žicu.
  • Za ugradnju na vlažnim mjestima, zaštitite GFCI utičnicu poklopcem otpornim na vremenske uvjete koji će i utičnicu i sve utikače držati suhima.
  • Always consult a qualified electrician if you are unsure about any part of the installation process.
Child's hand near a GFCI outlet, illustrating tampkarakteristika otpornosti na er.

Image: The tamper-resistant design of the GFCI outlet helps prevent accidental insertion of foreign objects by children, enhancing safety.

2. Proizvod je gotovview

The ANKO GFCI Outlet is a high-quality, tamper-resistant, and weather-resistant receptacle designed to provide enhanced electrical safety in both indoor and outdoor environments. It features an LED indicator for status monitoring and performs automatic self-tests to ensure continuous ground fault protection.

ANKO GFCI Outlet with key features highlighted: UL Listed, Tamper Resistant, Weather Resistant, 20A/125V/2500W with LED Indicator, Standard Wall Plate & Screws Included, Performs a Self-Test Every 40 Seconds, Back and Side Wire.

Slika: Prekoview of the ANKO GFCI Outlet, detailing its UL listing, tamper and weather resistance, electrical ratings, self-test capability, and wiring options.

Ključne karakteristike

  • GFCI zaštita: Constructed with premium high-impact resistant thermoplastic materials, ensuring superior strength and durability. Designed to meet local and national electrical codes.
  • sigurnost: UL-Listed YGB-095WR, 20 Amp, 125 Volt, 60HZ. Tamper-Resistant Receptacle prevents children from inserting unwanted objects.
  • Otporan na vremenske uslove: Advanced UV stabilized engineering provides superior corrosion, temperature, and UV resistance, preventing discoloration and aging. Ideal for outdoor and indoor use in areas subject to moisture.
  • Funkcija samotestiranja: Automatically conducts a Self-Test every 40 seconds to ensure continuous ground fault protection.
  • LED indikator: Two indicator lights provide intuitive feedback on power and protection status (green for proper function, red for end-of-life).
  • Jednostavna instalacija: Can be easily installed in an electric box, with included unbreakable polycarbonate decorator wall plates and screws.

3. Specifikacije

AtributVrijednost
Dimenzije proizvoda10.67 x 4.57 x 4.06 cm
Težina699 g
ProizvođačANKO
ASINB085W95DXB
Referenca proizvođačaANKPS-301-4P
BrandANKO
BojaBijelo
MaterijalPlastic, Thermoplastic
Totalne utičnice2
Voltage125 Volts
AmpDob20 Amps
UPC638183948767
Dimensions of the ANKO GFCI outlet and its accompanying wall plate.

Image: Detailed dimensions of the GFCI outlet and the standard wall plate for proper fit and installation planning.

4. Instalacija

Kontrolna lista prije instalacije

  • Ensure power is OFF at the circuit breaker or fuse box.
  • Verify the existing electrical box is suitable for the GFCI outlet.
  • Have necessary tools: screwdriver, wire strippers, electrical tape.
  • Confirm you are using copper or copper-clad wiring.

Wiring Diagrams and Steps

The ANKO GFCI outlet supports both back and side wiring. Follow the appropriate diagram based on your electrical setup.

Detailed wiring diagram for the ANKO GFCI outlet, showing terminals for Grounding, Line White, Line Hot, Load White, and Load Hot connections.

Image: Terminal identification for wiring the GFCI outlet, including grounding, line (incoming power), and load (outgoing power to other receptacles) connections.

Wiring diagrams for GFCI outlet installation with one cable (2-3 wires) and two cables (4-6 wires) entering the electrical box.

Image: Visual guide for connecting the GFCI outlet in both single-cable and multi-cable electrical box configurations, showing line and load connections.

  1. Isključite napajanje: Locate the circuit breaker controlling the outlet and switch it to the OFF position. Verify power is off using a voltage tester.
  2. Uklonite staru utičnicu: Carefully remove the existing wall plate and unscrew the old outlet from the electrical box. Disconnect the wires.
  3. Identifikujte žice: Identify the LINE (incoming power) wires and LOAD (outgoing power to other outlets on the same circuit) wires. If unsure, consult a professional.
  4. Spojite žice:
    • Connect the LINE (hot/black) wire to the brass LINE terminal.
    • Connect the LINE (neutral/white) wire to the silver LINE terminal.
    • Connect the LOAD (hot/black) wire to the brass LOAD terminal (if applicable).
    • Connect the LOAD (neutral/white) wire to the silver LOAD terminal (if applicable).
    • Connect the bare copper or green insulated GROUND wire to the green grounding screw.
  5. Secure Outlet: Gently fold the wires into the electrical box and secure the GFCI outlet with the provided screws.
  6. Instalirajte zidnu ploču: Attach the decorator wall plate.
  7. Vrati snagu: Ponovo uključite napajanje na prekidaču.
  8. Test GFCI: Press the TEST button, then the RESET button. The GFCI should trip and reset, indicating proper function.
A person installing a GFCI outlet into an outdoor electrical box using a screwdriver.

Slika: Bivši/aample of installing the GFCI outlet into a weatherproof outdoor electrical box.

5. Operacija

GFCI Functionality

A GFCI (Ground Fault Circuit Interrupter) receptacle is designed to protect against electrical shock by detecting ground faults. When a ground fault is detected (e.g., electricity flowing through an unintended path, such as a person's body), the GFCI will trip within a fraction of a second, interrupting the flow of electricity to prevent serious injury.

Diagram explaining 'What is a GFCI?' showing how it trips to prevent injury and detailing the green and red LED indicators for proper function and end-of-life.

Image: Explanation of GFCI operation, including the definition of a ground fault and the meaning of the green and red indicator lights.

Self-Test and Indicator Lights

  • Automatsko samotestiranje: The GFCI outlet automatically conducts a self-test (the red light will blink once) every 40 seconds to ensure it is continually working and providing protection.
  • Zelena indikatorska lampica: If the indicator (LED) glows green, it signifies that the GFCI receptacle is installed correctly and is working properly.
  • Crvena indikatorska lampica: When the GFCI receptacle reaches the end of its life or is incapable of passing its internal test function (meaning it can no longer provide ground fault protection), the red indicator light will turn on. This reminds you to replace the outlet promptly.
  • TEST dugme: Press this button to manually test the GFCI's tripping function. The power to the connected devices should cut off.
  • Dugme RESET: After a trip (either from a ground fault or a test), press this button to restore power to the outlet.

6. Održavanje

The ANKO GFCI Outlet requires minimal maintenance. Regular testing is the most important aspect of ensuring its continued safety and functionality.

  • Mjesečno testiranje: It is recommended to test your GFCI outlets monthly. Press the TEST button, then the RESET button. The outlet should trip and then reset. If it does not trip, or if it does not reset, the GFCI is faulty and should be replaced immediately.
  • čišćenje: To clean the surface of the GFCI outlet and wall plate, use a soft, damp cloth. Do not use abrasive cleaners or solvents, as these can damage the finish or internal components. Ensure power is off before cleaning.
  • inspekcija: Periodically inspect the outlet and wall plate for any signs of damage, cracks, or discoloration. If any damage is observed, replace the unit.

7. Otkrivanje problema

Uobičajeni problemi i rješenja

ProblemMogući uzrokRješenje
GFCI will not resetGround fault present; Mis-wired; End of life.Unplug all appliances from the GFCI and try to reset. If it resets, an appliance is faulty. If not, check wiring for errors (LINE/LOAD reversal). If still no reset, the GFCI may be at its end of life and needs replacement.
GFCI trips frequentlyFaulty appliance; Moisture in the circuit; Overload.Identify and unplug the faulty appliance. Ensure the outlet is protected from moisture in wet locations. Reduce the load on the circuit.
Nema struje u utičniciCircuit breaker tripped; GFCI tripped; Incorrect wiring.Check and reset the circuit breaker. Press the RESET button on the GFCI. Verify wiring connections are secure and correct (LINE and LOAD are not reversed).
Crvena indikatorska lampica je upaljenaGFCI has reached its end of life.The GFCI outlet needs to be replaced immediately to ensure continued protection.

8. Garancija i podrška

For specific warranty information regarding your ANKO GFCI Outlet, please refer to the packaging or contact ANKO customer support directly. Keep your purchase receipt as proof of purchase.

If you encounter any issues or have questions not covered in this manual, please reach out to ANKO customer service for assistance. Contact details are typically available on the product packaging or the manufacturer's official website.

Povezani dokumenti - ANKPS-301-4P

Preview Anko niske jačine zvukatage 4ft Santa Inflatable: Installation and Safety Guide
Sveobuhvatni vodič za Anko Low Voltage 4ft Santa Inflatable, covering installation, safety warnings, and adaptor manual. Model JT-DC12V9W-F3, Keycode 43069835.
Preview Anko Bluetooth vodootporni šareni plutajući zvučnik - korisnički vodič
Korisnički priručnik za Anko Bluetooth vodootporni šareni plutajući zvučnik (model 43206056), s detaljnim specifikacijama, uputama za upotrebu, funkcijama tipki i važnim sigurnosnim mjerama opreza.
Preview Anko vodootporni zvučnik patka Korisnički priručnik
Korisnički priručnik za Anko vodootporni zvučnik u obliku patke (Model: EBS-24106), u kojem su detaljno opisane njegove karakteristike, rad, specifikacije i informacije o garanciji.
Preview Anko LV 600 LED lampe - uputstvo za upotrebu i sigurnosne informacije
Detaljan korisnički vodič i sigurnosna upozorenja za Anko LV 600 LED višenamjenske toplo bijele lampe (Model SL2810-C(WWW)). Uključuje uputstvo za adapter, funkcije i važne upute za upotrebu.
Preview Anko 600 LED toplo bijelih lampi - Sigurnosni priručnik i uputstvo za instalaciju
Sveobuhvatne sigurnosne upute, upozorenja i vodič za instalaciju za Anko Low Voltage 600 LED toplo bijelih lampi (Model JT-EL/FC31V3.6W-H9, Ključni kod 43199334). Naučite kako sigurno postaviti i koristiti ove dekorativne lampe za unutrašnju upotrebu.
Preview Anko 43308026 Christmas Battery Operated Light Up North Pole Sign - User Guide
Detailed instructions and assembly guide for the Anko 43308026 Christmas Battery Operated Light Up North Pole Sign. Learn how to set up, use, and care for your festive holiday decoration.