The Elitech RC-5+ TE is a versatile digital USB temperature data logger designed for reliable and accurate temperature monitoring across various applications, including life sciences, food cold chain, and industrial fields. This device features both an internal and an external sensor, allowing for flexible measurement options. It generates automatic PDF reports without requiring special software, simplifying data access and analysis. The RC-5+ TE is compliant with FDA 21 CFR Part 11 standards, ensuring high quality and regulatory adherence.

Image: Elitech RC-5+ TE Reusable Temperature Data Logger, ideal for cold chain transportation temperature monitoring.
Ključne karakteristike:
- Dvostruki senzori: Equipped with both internal and external temperature probes for comprehensive monitoring.
- Automatski PDF izvještaj: Generates PDF reports directly upon USB connection, no proprietary software needed for basic data access.
- visoka preciznost: Provides precise temperature readings with a low margin of error.
- Large Data Capacity: Čuva do 32,000 podataka.
- Široki temperaturni raspon: Suitable for extreme cold and heat, from -40°C to +85°C (-40°F to 185°F) with the external probe.
- IP67 vodootporan: Offers robust protection against water and dust.
- Konfigurabilni parametri: Allows setting of temperature units, alarm ranges, and logging intervals.
- Dug vijek trajanja baterije: Up to 1 year of operation on a single CR2032 battery.
Product Overview video:
Video: Prekorview of the Elitech RC-5+ and RC-5+ TE temperature data loggers, highlighting their features and applications.
2. Šta se nalazi u kutiji
Upon opening your Elitech RC-5+ TE package, you should find the following items:
- Elitech RC-5+ TE Data Logger
- USB External Probe/Sensor
- Potvrda o kalibraciji
- Uputstvo za upotrebu

Image: The Elitech RC-5+ TE package includes the data logger, external probe, calibration certificate, and user manual.
3. Podešavanje
3.1 Instalacija baterije
The RC-5+ TE uses a CR2032 lithium metal battery. To install or replace the battery:
- Pronađite odjeljak za baterije na stražnjoj strani loggera podataka.
- Use a coin or small tool to twist and open the battery cover.
- Umetnite CR2032 bateriju s pozitivnom (+) stranom okrenutom prema gore.
- Vratite poklopac baterije i okrenite ga da biste ga pričvrstili.

Image: Step-by-step guide for installing the CR2032 battery into the Elitech RC-5+ TE data logger.
3.2 Instalacija softvera i početna konfiguracija
While the RC-5+ TE can generate basic PDF reports without software, the Elitechlog software (available for Windows and Mac) provides advanced configuration options and detailed data analysis. To download and install the software:
- Posjetite službeni Elitech webstranica: www.elitechustore.com.
- Navigate to the 'Download' section and select 'Software'.
- Choose the appropriate software version for your operating system (Windows or Mac) and download the installer.
- Pratite uputstva na ekranu da biste dovršili instalaciju.
- Once installed, connect the RC-5+ TE to your computer's USB port.
- Open the Elitechlog software. Go to the 'Settings' tab (or 'Parameter' tab on Windows) to configure the device.
- Set the desired logging interval (from 10 seconds up to 12 hours), temperature unit (°C/°F), time zone, and alarm settings.
- For the RC-5+ TE, select whether to use the internal or external probe under 'Probe Type'.
- Click 'Save' to apply your settings to the device.
- Bezbedno izbacite uređaj iz računara.
Software Setup and Configuration Video:
Video: Detailed instructions on how to download, install, and configure the Elitechlog software for RC-5+ and RC-5+ TE data loggers.
3.3 Spajanje vanjskog senzora
The RC-5+ TE model includes an external sensor for more precise or remote temperature measurements. Simply plug the external sensor cable into the designated port on the data logger. Ensure it is securely connected.

Image: The Elitech RC-5+ TE with its external sensor connected and the USB port exposed.
4. Operacija
4.1 Početak snimanja
To begin temperature logging, press and hold the left play button (►) for approximately 5 seconds. The play sign will appear on the LCD, indicating that recording has started.
4.2 Stopping a Recording
To stop temperature logging, press and hold the right pause button (⏸) for approximately 5 seconds. The stop sign will appear on the LCD, indicating that recording has ceased.
4.3 Viewing Data on the LCD
Pritisnite left play button (►) briefly to cycle through the following display menus:
- Trenutna temperatura
- Number of Logged Readings
- Trenutno vrijeme
- Trenutni datum
- Maximum Temperature Recorded
- Minimum Temperature Recorded

Image: Visual representation of the Elitech RC-5+ TE LCD interface, showing various data points like temperature, logging points, time, date, and min/max values.
4.4 Marking Events
During logging, you can mark specific events by double-clicking the right pause button (⏸). This feature is useful for noting significant occurrences during the monitoring period.

Image: Instructions on how to clear data and restart the recorder, and how to double-click to mark an event on the Elitech RC-5+ TE.
5. Upravljanje podacima
5.1 Automatic PDF Report Generation
The RC-5+ TE automatically generates a PDF report when plugged into a computer's USB port. No special software is required to view this report.
- Ensure the data logger has stopped recording.
- Remove the protective cap from the USB connector.
- Plug the data logger into an available USB port on your computer.
- The device will appear as a removable drive. Open the drive to find the generated PDF report.

Image: The Elitech RC-5+ TE connected to a laptop, demonstrating automatic PDF and CSV report generation without additional software.
5.2 Exporting Data with Elitechlog Software
For more detailed analysis and export options (e.g., Excel, AELT), use the Elitechlog software:
- Connect the data logger to your computer and open the Elitechlog software.
- The software will automatically read the data from the device.
- Click on the 'Export Data' option within the software interface.
- Odaberite željeno file format (Excel, PDF, AELT) and specify a save location.
- Click 'Save' to export the data.

Image: The Elitechlog software interface showing data comparison graphs and tables from multiple loggers, allowing for powerful analysis.
6. Održavanje
6.1 Zamjena baterije
Refer to section 3.1 for detailed instructions on how to replace the CR2032 battery. It is recommended to replace the battery annually or when the low battery indicator appears on the LCD.
6.2 Čišćenje
To clean the data logger, simply wipe it with a clean, damp cloth. Avoid using abrasive cleaners or solvents that could damage the device. The device is freezer safe.
6.3 Vodootporna zaštita
The RC-5+ TE features an IP67 waterproof rating, meaning it is protected against dust ingress and immersion in water up to 1 meter for 30 minutes. Ensure the USB cap is securely in place to maintain its waterproof integrity.

Image: The Elitech RC-5+ TE data logger submerged in water, demonstrating its IP67 waterproof capability.
7. Otkrivanje problema
7.1 No Data Recorded / "Battery Too Low" Error
- Check the battery level on the LCD display. If low, replace the CR2032 battery (refer to section 3.1).
- Ensure the recording was properly started by pressing and holding the left play button until the play sign appears.
- Verify that the logging interval and start mode are correctly configured in the Elitechlog software.
7.2 "nC" Error (No Connection)
- This error typically indicates a problem with the external sensor connection. Ensure the external sensor is firmly plugged into the data logger's port.
- If the issue persists, try unplugging and re-plugging the sensor.
- If using the external sensor, ensure the 'Probe Type' setting in the Elitechlog software is set to 'External'.
7.3 Software Not Recognizing Device
- Ensure the Elitechlog software is correctly installed and updated to the latest version.
- Try connecting the data logger to a different USB port on your computer.
- Restart your computer and the Elitechlog software.
8. Specifikacije
| Feature | Specifikacija |
|---|---|
| Naziv modela | RC-5+ TE |
| Temperature Measurement Range (External Probe) | -40°C do +85°C (-40°F do 185°F) |
| Temperature Measurement Range (Internal Probe) | -30°C do +70°C (-22°F do 158°F) |
| Preciznost temperature | ±0.5°C/±0.9°F (-20°C to +40°C); ±1°C/±1.8°F (others) |
| Rezolucija | 0.1°C/°F |
| Kapacitet podataka | 32,000 poena |
| Interval evidentiranja | Configurable from 10 seconds to 12 hours |
| Postavke alarma | Up to 5 alarm settings |
| Povezivanje | USB |
| Waterproof Rating | IP67 |
| Vrsta baterije | CR2032 litijum metalna (uključena) |
| Trajanje baterije | Do 1 godine |
| Dimenzije | 3.2 x 1.3 x 0.5 inča |
| Težina artikla | 2.39 unce |
| Materijal | Plastika |
| Usklađenost | FDA 21 CFR Dio 11 |
9. Garancija i podrška
9.1 Informacije o garanciji
The Elitech RC-5+ TE Digital USB Temperature Data Logger comes with a 12-mjesečna garancija od datuma kupovine. Ova garancija pokriva nedostatke u proizvodnji i osigurava da proizvod ispunjava navedene standarde performansi. Molimo sačuvajte dokaz o kupovini za reklamacije u slučaju garancije.
9.2 Korisnička podrška
For any technical assistance, troubleshooting, or inquiries regarding your Elitech product, please contact Elitech Customer Support. They offer 24/7 support via email and phone.
- Podrška putem e-pošte: Refer to the Elitech website or your product packaging for the specific email address.
- Telefonska podrška: Refer to the Elitech website or your product packaging for the specific phone number.
- Online resursi: Visit the Elitech webstranica (www.elitechustore.com) for FAQs, software downloads, and additional user manuals.