The PEDROLLO Presscontrol Easy Press II is an advanced electronic device designed to automate the operation of single-phase electric pumps up to 2 HP. It manages the pump's start and stop functions based on water demand, activating the pump when a tap is opened and deactivating it when the tap is closed.

Equipped with microprocessor logic, the Easy Press II offers crucial protection features. It safeguards the pump against dry running, automatically or manually resetting the system after a dry-run event. Furthermore, it prevents excessively frequent pump starts, which can occur due to minor leaks in the water system, thereby extending the pump's lifespan and ensuring stable water pressure.

PEDROLLO Presscontrol Easy Press II Electronic Pressure Regulator

Slika 1: Prednja strana view of the PEDROLLO Presscontrol Easy Press II.

This image shows the compact design of the Easy Press II, featuring a pressure gauge, status indicators (Power, Out of Service, Dry, Running, Frequent Start-up), and the Pedrollo branding. The device is primarily white and blue with orange accents.

2. Ključne karakteristike

  • Automatic Pump Control: Starts and stops single-phase electric pumps based on water demand.
  • Zaštita od rada na suho: Microprocessor logic prevents pump damage from operating without water, with automatic or manual reset.
  • Zaštita od curenja: Protects the pump from frequent starts caused by small system leaks.
  • Integrated Pressure Gauge: Allows for easy monitoring of system pressure.
  • High Protection Rating: IP 65 rated for dust and water resistance, suitable for various environments.
  • Robustan dizajn: Izrađeno od izdržljivog plastičnog materijala.

3. Specifikacije

AtributVrijednost
ProizvođačPEDROLLO
ModelEasy Press II
Max Flow Rate200 litara u minuti (12 m³/h)
Radni pritisak10 bara
Start Pressure1.5 bara
Liquid Temperature LimitDo +65 °C
Ambient Temperature LimitDo +40 °C
Burst Pressure> 40 bara
Ocjena zaštiteIP 65
Voltage230 V
Frekvencija50/60 Hz
Maks. Struja16 A (for Easy Press II)
Težina artikla2 kilograma
BojaNarandžasta
MaterijalPlastika
Izvor napajanjaElektrični kabel

4. Sigurnosne informacije

Always read and understand all safety warnings and instructions before installing, operating, or maintaining the PEDROLLO Presscontrol Easy Press II. Failure to follow these instructions could result in electric shock, fire, serious injury, or property damage.

  • Ensure the power supply matches the device's specifications (230V, 50/60Hz).
  • Sve električne priključke mora izvršiti kvalificirani električar i oni moraju biti u skladu s lokalnim električnim propisima.
  • Isključite napajanje prije izvođenja bilo kakve instalacije, održavanja ili rješavanja problema.
  • Do not operate the device if it is damaged or if the power cable is frayed.
  • Držite djecu i neovlašteno osoblje podalje od područja instalacije.
  • Osigurajte ispravno uzemljenje kako biste spriječili električne opasnosti.

5. Instalacija i podešavanje

The Easy Press II is designed for easy integration into single-phase electric pump systems. Proper installation is crucial for optimal performance and safety.

  1. Montaža: Install the Easy Press II vertically, ensuring the flow direction matches the arrows on the device. It should be mounted between the pump and the first point of water consumption.
  2. Hidraulični priključak: Connect the inlet of the Easy Press II to the pump's discharge and the outlet to the system's piping. Ensure all connections are watertight using appropriate sealants (e.g., PTFE tape).
  3. Električni priključak:
    • Connect the power supply cable to the Easy Press II's input terminals.
    • Connect the pump's power cable to the Easy Press II's output terminals.
    • Ensure all connections are secure and properly insulated. Refer to the wiring diagram provided in the technical documentation (Figure 2).
  4. Priprema sistema: Before starting the pump, ensure the pump and the Easy Press II are fully primed with water to prevent dry running.
  5. Prvo pokretanje: Once all connections are secure and the system is primed, restore power. The Easy Press II will initiate the pump when water demand is detected.
PEDROLLO Presscontrol Easy Press II Technical Diagram and Dimensions

Figure 2: Technical diagram and dimensions of the PEDROLLO Easy Press II.

This image provides detailed technical specifications, performance curves, and dimensional drawings for the Easy Press II. It illustrates various models (Easy Press 1, Easy Press 2) and their electrical characteristics, as well as typical installation setups and physical dimensions.

6. Operacija

The PEDROLLO Easy Press II operates automatically once installed and powered. It functions as an electronic flow and pressure switch.

  • Pump Start: When a tap or valve in the system is opened, causing a drop in pressure and flow, the Easy Press II detects this demand and automatically starts the connected electric pump.
  • Pump Stop: When all taps or valves are closed, and water flow ceases, the Easy Press II detects the absence of flow and stops the pump after a short delay, maintaining system pressure.
  • Indikatori statusa: The device features LED indicators (Power, Out of Service, Dry, Running, Frequent Start-up) to provide visual feedback on its operational status. Refer to the device's front panel for specific indicator meanings.

7. Održavanje

The PEDROLLO Easy Press II is designed for minimal maintenance. However, regular checks can help ensure its longevity and reliable operation.

  • Redovni pregled: Periodically check the device and its connections for any signs of leaks, damage, or corrosion.
  • čistoća: Keep the exterior of the device clean and free from dust or debris. Do not use abrasive cleaners.
  • Zimovanje (ako je primjenjivo): In areas subject to freezing temperatures, ensure the device and connected piping are drained or protected from frost to prevent damage.
  • Pressure Gauge Check: Monitor the pressure gauge regularly to ensure it is functioning correctly and providing accurate readings.

Always disconnect power to the device before performing any maintenance or inspection.

8. Otkrivanje problema

The Easy Press II incorporates intelligent features to protect the pump and indicate operational issues. Here are common scenarios and their resolutions:

  • Pump Not Starting / "Dry" Indicator On:
    • Uzrok: Dry running detected (no water in the pump or suction line).
    • Rješenje: Ensure the pump is primed with water. The Easy Press II may attempt an automatic reset after a period. If not, manually reset the device by pressing the "START/STOP" button or by cycling the power.
  • Pump Cycling Frequently / "Frequent Start-up" Indicator On:
    • Uzrok: Small leaks in the system (e.g., dripping tap, faulty toilet fill valve) or a non-return valve issue.
    • Rješenje: Inspect all plumbing fixtures and connections for leaks. Repair any leaks found. Check the non-return valve in the system for proper operation.
  • Pump Not Stopping:
    • Uzrok: Continuous water flow (e.g., open tap, major leak) or a sensor malfunction.
    • Rješenje: Close all taps and check for significant leaks. If the pump continues to run without demand, disconnect power and contact a qualified technician.
  • No Power / "Power" Indicator Off:
    • Uzrok: No electrical supply to the device.
    • Rješenje: Check the circuit breaker, fuses, and power connections. Ensure the power outlet is functional.

For issues not covered here, or if troubleshooting steps do not resolve the problem, contact a qualified technician or the manufacturer's support.

9. Garancija i podrška

Information regarding the specific warranty period and terms for the PEDROLLO Presscontrol Easy Press II is typically provided at the point of purchase or within separate documentation accompanying the product. Please retain your proof of purchase for warranty claims.

For technical support, spare parts, or service inquiries, please contact your authorized PEDROLLO dealer or the manufacturer directly. Information on spare parts availability was not provided in the product details.

Manufacturer: PEDROLLO

Povezani dokumenti - Easy Press II

Preview Pedrollo PRESFLO MULTI automatski kontrolni uređaj - tehnički list
Tehnički list za Pedrollo PRESFLO MULTI, elektronski uređaj za kontrolu i zaštitu jednofaznih kućnih pumpi. Detalji o karakteristikama, specifikacijama, instalaciji i podešavanju za sisteme vodosnabdijevanja i navodnjavanja.
Preview Pedrollo EP elektronska zaštita pumpe: Vodič za instalaciju i upotrebu
Sveobuhvatan vodič za Pedrollo EP elektronsku zaštitu pumpe, s detaljnim opisom njenih funkcija za rad na suho, prekomjernu struju i preopterećenje.tage zaštitu, zajedno s uputama za instalaciju i upotrebu.
Preview Pedrollo PRESFLO MULTI automatski kontrolni uređaj - Tehničke specifikacije
Detaljne tehničke specifikacije, vodič za instalaciju i karakteristike Pedrollo PRESFLO MULTI automatskog elektronskog uređaja za regulaciju pritiska za vodosnabdijevanje domaćinstava i povišenje pritiska.
Preview Pedrollo EP elektronski zaštitni uređaj - korisnički priručnik i tehnički list
Sveobuhvatan vodič za Pedrollo EP elektronski zaštitni uređaj, koji detaljno opisuje njegove karakteristike, tehničke specifikacije, instalaciju i rad. Štiti pumpe od rada na suho, prekomjerne struje i prenapona.tage, i undervoltage. Pogodno za kućnu upotrebu.
Preview EVOLUTION Elektronska kontrolna ploča za električne pumpe - PEDROLLO Uputstvo za upotrebu
Sveobuhvatno korisničko uputstvo za PEDROLLO EVOLUTION elektronsku kontrolnu ploču, koje detaljno opisuje instalaciju, rad, programiranje, tehničke specifikacije i rješavanje problema za jednofazne i trofazne električne pumpe.
Preview Pedrollo E1-E2 Elektronske električne ploče za pumpe
Sveobuhvatan vodič za Pedrollo E1 i E2 elektronske kontrolne panele, dizajnirane za upravljanje sistemima sa jednom ili dvije pumpe u stambenim, komercijalnim i industrijskim okruženjima. Karakteristike uključuju odabir načina rada, zaštitu od rada na suho i intuitivna korisnička sučelja za efikasan rad pumpe.