Uvod
This manual provides essential information for the safe and effective use of the Idec RH4B-UAC120V Power Relay. This device is designed for reliable electrical switching applications, featuring a 4PDT contact configuration and operating on a 120VAC coil voltage. Please read this manual thoroughly before installation and operation.
Sigurnosne mjere
Uvijek se pridržavajte sljedećih sigurnosnih mjera opreza kako biste spriječili strujni udar, požar ili oštećenje proizvoda:
- Ensure power is disconnected before installation, wiring, or maintenance.
- All wiring should be performed by qualified personnel in accordance with local electrical codes.
- Nemojte prekoračiti navedeni volumentage i trenutne ocjene.
- Avoid installing the relay in environments with excessive moisture, dust, corrosive gases, or vibrations.
Postavljanje i instalacija
The RH4B-UAC120V Power Relay is designed for socket mounting. Follow these general steps for installation:
- Montaža: Securely mount the appropriate relay socket (not included) in a stable location, typically on a DIN rail or panel.
- Ožičenje: Connect the control circuit to the coil terminals and the load circuit to the contact terminals. Refer to the wiring diagram provided with your relay socket or system documentation for specific pin assignments. Ensure all connections are tight and secure.
- Umetanje: Carefully insert the RH4B-UAC120V relay into its socket, ensuring all pins align correctly with the socket terminals. Apply gentle, even pressure until the relay is fully seated.
- Potvrda: Before applying power, double-check all wiring connections for correctness and ensure no loose strands or short circuits are present.

Figure 1: Idec RH4B-UAC120V Power Relay. This image shows the compact design of the relay with its transparent casing, revealing the internal contacts and coil, and the multiple pins for socket connection at the base.
Uputstvo za upotrebu
The RH4B-UAC120V Power Relay operates automatically based on the presence or absence of voltage across its coil terminals. It functions as a switch to control higher power circuits or to provide isolation between control and load circuits.
- Coil Activation: When 120VAC is applied to the relay's coil, an electromagnetic field is generated, causing the internal contacts to switch their state.
- Contact Switching: The 4PDT (Four Pole Double Throw) configuration means the relay has four independent sets of contacts, each capable of switching between two positions (normally open to closed, or normally closed to open).
- Deaktivacija: When the 120VAC supply to the coil is removed, the electromagnetic field collapses, and the contacts return to their original (de-energized) state.
Ensure the load connected to the contacts does not exceed the 10 Amps current rating to prevent damage to the relay and connected equipment.
Održavanje
The RH4B-UAC120V Power Relay is designed for long-term reliability with minimal maintenance. However, periodic inspection is recommended to ensure optimal performance and longevity.
- Vizuelni pregled: Regularly check the relay and its socket for any signs of physical damage, discoloration, or loose connections.
- Provjera okoliša: Ensure the operating environment remains within specified conditions (temperature, humidity, absence of corrosive substances).
- čišćenje: If dust or debris accumulates, gently clean the exterior of the relay and socket using a soft, dry cloth. Do not use solvents or abrasive cleaners.
- Kontakt Life: Relays have a finite number of switching cycles. If the relay is used in a high-frequency switching application, consider periodic replacement based on manufacturer's recommendations or observed performance degradation.
Rješavanje problema
If the RH4B-UAC120V Power Relay does not function as expected, consider the following common issues and solutions:
| Problem | Mogući uzrok | Rješenje |
|---|---|---|
| Relay does not energize (contacts do not switch) |
|
|
| Contacts do not switch reliably or chatter |
|
|
| Relay overheats |
|
|
If problems persist, consult a qualified electrician or contact Idec technical support.
Specifikacije
| Atribut | Vrijednost |
|---|---|
| Broj modela | RH4B-UAC120V |
| Brand | Idec |
| Vrsta kontakta | 4PDT (Four Pole Double Throw) |
| Current Rating | 10 Amps |
| Coil Voltage | 120 V AC |
| Način rada | Automatski |
| Proizvođač | IDEC |
| Dimenzije (približne) | 27.5 x 41 x 42 mm |
Garancija i podrška
For information regarding warranty coverage, technical support, or service, please refer to the official Idec website or contact your authorized Idec distributor. Keep your purchase receipt as proof of purchase.
Idec Official Webstranica: https://us.idec.com/





