The Apera Instruments PH820 Benchtop pH Meter Kit is designed for reliable and accurate pH measurements in laboratory settings. It features advanced functionalities including intelligent calibration, data management, and a durable, water-resistant structure. This manual provides detailed instructions for proper use and care of your PH820 meter.

Apera Instruments PH820 Benchtop pH Meter Kit with electrode and stand

Figure 1: Apera Instruments PH820 Benchtop pH Meter Kit, showing the main unit, electrode, temperature probe, and electrode arm.

Key features of the PH820 include:

Setup

Raspakivanje i provjera komponenti

Carefully unpack all components from the kit. Verify that the following items are present:

Povezivanje komponenti

Connect the electrode, temperature probe, and power adapter to the corresponding ports on the back of the PH820 meter unit. Ensure all connections are secure.

Back panel of Apera Instruments PH820 pH meter showing connection ports

Slika 2: Pozadi view of the PH820 meter, highlighting the REF, pH/mV, TEMP, RS232, and DC 9V input ports.

  1. Povezivanje elektrode: Plug the LabSen 211 pH Electrode into the port labeled "pH/mV".
  2. Priključak temperaturne sonde: Insert the temperature probe into the port labeled "TEMP".
  3. Priključak za napajanje: Connect the power adapter to the "DC 9V" port and then to a power outlet.
  4. Electrode Arm Assembly: Attach the flexible electrode arm and holder to the side of the meter unit for convenient electrode placement during measurements.

Uputstvo za upotrebu

Basic pH Measurement

  1. Uključite mjerač pritiskom na dugme za napajanje.
  2. Rinse the electrode with distilled water and gently blot dry.
  3. Immerse the electrode and temperature probe into the sample solution. Ensure the electrode tip is fully submerged.
  4. Wait for the reading on the large LCD to stabilize. The meter displays pH and temperature simultaneously.
  5. Record the stable reading.

pH kalibracija

The PH820 supports 1 to 5 points automatic calibration. Regular calibration ensures measurement accuracy.

  1. Prepare the standard calibration solutions (4.00 pH, 7.00 pH, 10.01 pH are included).
  2. Pritisnite CAL dugme za ulazak u režim kalibracije.
  3. Rinse the electrode and immerse it into the first calibration solution (e.g., 7.00 pH).
  4. The meter will automatically recognize the solution and begin calibration. Wait for the stability icon to appear.
  5. Once stable, the meter will prompt for the next calibration point. Repeat the rinsing and immersion process for subsequent solutions.
  6. The self-diagnosis function will provide feedback on the calibration process and electrode condition, including slope data.
  7. Exit calibration mode once all desired points are completed.

Upravljanje podacima

The PH820 allows for GLP data management, storing up to 500 groups of data. Data can be output via USB to a PC using the provided PC-Link software (Windows-based system only). Auto-timing data logging can also be configured.

ORP Measurement (Optional)

The PH820 can measure Oxidation-Reduction Potential (ORP) when an ORP electrode (e.g., 301Pt-C, sold separately) is connected to the pH/mV port. Refer to the ORP electrode's specific instructions for calibration and measurement procedures.

Održavanje

Electrode Care

Proper care of the LabSen 211 pH Electrode is crucial for maintaining accuracy and extending its lifespan.

Close-up of the LabSen 211 pH electrode

Slika 3: Krupni plan view of the LabSen 211 pH Electrode, showing its glass body and sensor tip.

Meter Care

The PH820 meter unit is IP54 water-resistant, meaning it is protected from dust and splashing water. However, it should not be submerged. Keep the meter clean and dry. Use a soft, damp cloth to wipe the surface. Avoid using abrasive cleaners or solvents.

Rješavanje problema

The PH820 features a self-diagnosis function that can assist in identifying and fixing common problems, particularly during calibration. Refer to the meter's display for diagnostic messages.

ProblemMogući uzrokRješenje
Unstable ReadingsDirty electrode; air bubbles; insufficient sample volume; expired calibration.Clean electrode; ensure no bubbles; use adequate sample; recalibrate.
Calibration FailureIncorrect buffer solution; contaminated electrode; electrode aging.Use fresh, correct buffers; clean electrode; check electrode slope data (self-diagnosis) for replacement indication.
Nema ekrana/napajanjaPower adapter issue; loose connection.Check power adapter and outlet; ensure all cables are securely connected.
Inaccurate ReadingsElectrode not calibrated; temperature not compensated; damaged electrode.Perform calibration; ensure temperature probe is functioning; inspect electrode for damage.

For persistent issues not resolved by the above, please contact Apera Instruments customer support.

Specifikacije

ParametarVrijednost
Broj modelaAI531
pH tačnost±0.002 pH±1 digit
Calibration Points1 to 5 points (Auto.)
Skladištenje podataka500 groups (GLP compliant)
Izlaz podatakaUSB (PC software support)
Otpornost na voduIP54
Power Input120V AC 60Hz
Izlazna snaga9V 300mA
Dimenzije paketa10.67 x 10.2 x 6.65 inča
Težina6.69 funti
CertifikatiCE, RoHS, ISO 9001:2015

Garancija i podrška

Apera Instruments products are manufactured under an ISO 9001:2015 certified quality system, ensuring high standards of production. For specific warranty information and technical support, please refer to the warranty card included with your product or visit the official Apera Instruments website. You may also contact their customer service directly for assistance with product operation, troubleshooting, or parts replacement.

Povezani dokumenti - AI531

Preview Apera PH60Z-WW pametni pH metar - uputstvo za upotrebu
Sveobuhvatno korisničko uputstvo za Apera PH60Z-WW pametni pH metar, koje obuhvata podešavanje, kalibraciju, mjerenje, rješavanje problema i specifikacije za otpadne vode, suspenzije i emulzije.
Preview PH60Z-HT Pametni pH metar - Uputstvo za upotrebu - Apera Instruments
Korisnički priručnik za Apera Instruments PH60Z-HT pametni pH metar, u kojem su detaljno opisane njegove karakteristike, rad, kalibracija, održavanje i rješavanje problema za visokotemperaturne i kaustične rastvore.
Preview Apera SX811-SS Prijenosni pH metar za testiranje hrane: Uputstvo za upotrebu i specifikacije
Sveobuhvatno uputstvo za upotrebu i tehničke specifikacije za prenosivi pH metar Apera SX811-SS, dizajniran za precizno testiranje hrane. Saznajte više o funkcijama, kalibraciji, podešavanju, USB komunikaciji i rješavanju problema.
Preview Apera PH60Z-MS Smart pH-metar: Bedienungsanleitung für Kleinvolumenmessungen
Diese Bedienungsanleitung bietet detaillierte Informationen zur Verwendung des Apera PH60Z-MS Smart pH-metara, einschließlich Kalibrierung, Messung, Wartung i Fehlerbehebung za präzise pH-Messungen u kleinen Vollumina.
Preview Apera PH60-HT pH metar - uputstvo za upotrebu: Visokotemperaturne i kaustične otopine
Comprehensive user manual for the Apera PH60-HT pH Meter, designed for accurate pH measurement in high temperature (up to 140°C) and caustic solutions. Covers kit contents, operation, calibration, electrode care, parameter settings, technical specifications, troubleshooting, and warranty.
Preview Apera PH700 Benchtop pH Meter Instruction Manual
Comprehensive instruction manual for the Apera PH700 Benchtop pH Meter, covering features, specifications, operation, calibration, maintenance, and troubleshooting.