Uvod
The Veho Discovery DX-1 is a USB digital microscope designed for detailed observation, photo capture, and video recording. Featuring a 2-megapixel HD CMOS lens and 100x to 200x digital magnification, it is compatible with both Windows and Apple Mac operating systems through the MicroCapture software. This manual provides essential information for setting up, operating, and maintaining your DX-1 microscope.
Šta je u kutiji
Molimo Vas da provjerite da li su sve komponente prisutne prije nego što nastavite s postavljanjem:
- Veho DX-1 Microscope
- Uputstvo za upotrebu
- Softverski CD
- Kalibracioni lenjir
- Stalak za kolevku
- Krpa za čišćenje

Image: All components included in the Veho DX-1 package, including the microscope, stand, software CD, user guide, calibration ruler, and cleaning cloth.
Setup
- Assemble the Cradle Stand: Carefully attach the microscope to the adjustable cradle stand. Ensure all connections are secure.
- Instalacija softvera:
- Umetnite priloženi CD sa softverom u CD/DVD uređaj vašeg računara.
- Follow the on-screen instructions to install the MicroCapture software.
- Alternatively, download the latest software version from the official Veho support website if a CD drive is not available or for updated compatibility.
- Connect the Microscope: Plug the USB cable from the Veho DX-1 microscope into an available USB port on your computer (PC or Mac). The device should be recognized automatically after software installation.
- Pozicioniranje: Place the microscope on a stable surface. Use the adjustable stand to position the microscope over the object you wish to observe.

Image: The Veho DX-1 microscope in use, connected via USB to a laptop, observing a small circuit board on a wooden surface.
Uputstvo za upotrebu
- Launch MicroCapture Software: Open the MicroCapture application on your computer. The microscope's live feed should appear on the screen.
- Adjust Focus and Magnification:
- Rotate the focus wheel on the microscope body to achieve a clear image.
- The DX-1 offers 100x to 200x digital magnification. Adjust the distance between the microscope lens and the object, and fine-tune with the focus wheel for desired magnification.

Slika: Detaljna view of the silver magnification and focus adjustment dial located on the body of the Veho DX-1 microscope.
- Adjust LED Illumination: The microscope features 8 built-in LED lights. Use the light adjustment control (typically a small wheel or button on the microscope body or within the software) to brighten or dim the illumination for optimal viewing.
- Capture Photos and Videos:
- Within the MicroCapture software, locate the photo capture button (often represented by a camera icon) to take still images.
- Locate the video recording button (often represented by a video camera icon) to start and stop video capture.
- Zarobljeno files are typically saved to a designated folder on your computer, configurable within the software settings.

Image: The front end of the Veho DX-1 microscope, showing the clear lens cover and the ring of 8 bright LED lights surrounding the camera sensor.
- kalibracija: Use the included calibration ruler with the MicroCapture software's calibration function to accurately measure objects viewed through the microscope. Refer to the software's help section for detailed calibration steps.
Održavanje
- Čišćenje sočiva: Use the provided cleaning cloth or a soft, lint-free cloth specifically designed for optical lenses. Gently wipe the lens to remove dust or smudges. Avoid abrasive materials or harsh chemicals.
- Čišćenje tijela: Wipe the microscope body and stand with a soft, dry cloth. If necessary, a slightly damp Može se koristiti krpa, ali pazite da vlaga ne uđe u uređaj.
- Skladištenje: When not in use, store the microscope in a clean, dry place, away from direct sunlight and extreme temperatures. Keep it protected from dust.
- Održavanje kablova: Avoid bending or kinking the USB cable excessively to prevent internal damage.
Rješavanje problema
- Microscope Not Detected:
- Ensure the USB cable is securely connected to both the microscope and the computer.
- Pokušajte s drugim USB portom na svom računaru.
- Restart the MicroCapture software or your computer.
- Verify that the necessary drivers were installed correctly during software setup. Reinstall the software if needed.
- Unclear or Blurry Image:
- Adjust the focus wheel on the microscope body.
- Ensure the object is within the microscope's working distance.
- Clean the microscope lens with the provided cleaning cloth.
- Adjust the LED illumination for better contrast.
- Problemi sa softverom:
- If the MicroCapture software is unresponsive or crashes, close and restart the application.
- Check for software updates on the Veho support website.
- Consult the software's built-in help documentation for specific feature usage and advanced troubleshooting.
- Stabilnost postolja: Ensure the microscope is properly secured in the cradle stand and the stand is placed on a flat, stable surface to prevent wobbling during observation.
Specifikacije
| Feature | Detalj |
|---|---|
| Broj modela | VMS-006-DX1 |
| Objektiv | 2 Mega Pixels HD CMOS |
| Rezolucija | 1920x1080 |
| Uvećanje | 100x - 200x Digital |
| Izvor svjetlosti | 8 LED svjetla |
| DSP | High speed DSP |
| Kompatibilnost | Windows, Apple Mac |
| Dimenzije proizvoda | 4.33 x 2.76 x 0.49 inča |
| Težina artikla | 11.3 unce |
| Snaga | 5 Volts (USB powered) |
Garancija i podrška
The Veho Discovery DX-1 USB Digital Microscope is covered by a manufacturer's warranty. Please refer to the warranty card included in your product packaging or visit the official Veho webstranicu za detaljne uslove i odredbe garancije.
For technical support, software updates, or further assistance, please visit the Veho support portal or contact their customer service department. Contact details are typically available on the official Veho website.