The DAB E.SYBOX is an integrated electronic water booster system designed for domestic and residential applications. This system provides constant water pressure while optimizing energy consumption. It is suitable for use with potable water in domestic plants, for gardening, and irrigation. The E.SYBOX can also be used to create groups of up to four pumps.
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your E.SYBOX system. Please read it thoroughly before installation and keep it for future reference.
2. Sigurnosne informacije
WARNING: Before performing any operation on the pump, disconnect it from the main power supply.
- Osigurajte napajanje voltage matches the specifications of the E.SYBOX (230V).
- Instalaciju i održavanje treba obavljati samo kvalificirano osoblje.
- Do not operate the pump with flammable or explosive liquids.
- Zaštitite uređaj od niskih temperatura.
- Osigurajte odgovarajuću ventilaciju oko jedinice kako biste spriječili pregrijavanje.
- Jedinica mora biti pravilno uzemljena.
3. Sadržaj paketa
Prilikom raspakivanja provjerite da li su sve komponente prisutne i neoštećene:
- DAB E.SYBOX Water Booster System Unit
- Kabl za napajanje
- Connection Pieces (e.g., 1" plastic unions)
- Korisnički priručnik (ovaj dokument)
4. Postavljanje i instalacija
The E.SYBOX is designed for straightforward installation and requires no additional components for basic setup. It can be installed either vertically or horizontally.
4.1. Odabir lokacije za instalaciju
Odaberite lokaciju koja je:
- Zaštićeno od direktne sunčeve svjetlosti i ekstremnih temperatura.
- In a closed space without a high level of air exchange, as the unit is water-cooled and quiet.
- Pristupačan za održavanje.
- Near the water source and the distribution system.
4.2. Fizička instalacija
- Pozicioniranje jedinice: Place the E.SYBOX on a stable, level surface. The anti-vibration feet help reduce noise. The unit can be positioned vertically or horizontally.
- Priključivanje vodovodnih cijevi: Connect the inlet pipe from your water source to the suction port and the outlet pipe to your distribution system. Use the provided 1" plastic unions for secure connections. Ensure all connections are watertight.
- Električni priključak: Connect the power cord to a grounded 230V AC outlet. Ensure the power supply is stable and protected from surges.
- Priming the Pump (if necessary): For initial startup or after maintenance, ensure the pump is filled with water before operation to prevent dry running. Refer to the display for priming instructions.

Slika 1: Prednja strana view of the DAB E.SYBOX unit, showing the display and general form factor.

Slika 2: Pozadi view of the E.SYBOX, highlighting the water inlet and outlet connections.
5. Uputstvo za upotrebu
The E.SYBOX features an adjustable, high-resolution LCD display for easy operation and monitoring.
5.1. Početno uključivanje
- Once connected to power, the LCD display will illuminate.
- Follow the on-screen prompts for initial setup, which may include language selection and basic pressure settings.
5.2. Podešavanje željenog pritiska
The E.SYBOX allows you to set your desired water pressure. The system will then maintain this constant pressure by adjusting pump speed.
- Navigate through the LCD menu using the control buttons adjacent to the display.
- Locate the "Pressure Setting" option.
- Adjust the pressure value (e.g., in PSI or Bar) to your preference. The system can deliver up to 210 ft (approx. 90 PSI) of head.
- Confirm your selection. The system will automatically adjust to maintain this pressure.

Figure 3: E.SYBOX display showing operational parameters such as power consumption (360W), pressure (3 Bar / 43 PSI), and flow rate (3.2 GPM / 12 l/min).
5.3. Praćenje učinka
The LCD display provides real-time statistics:
- pritisak: Current system pressure.
- Brzina protoka: Instantaneous water flow.
- Potrošnja energije: Energy consumption of the unit.
- Alarmi/Upozorenja: Notifications for any operational issues.
6. Održavanje
Regular maintenance ensures the longevity and optimal performance of your E.SYBOX system.
6.1. Rutinske provjere
- Vizuelni pregled: Periodically check for any leaks, unusual noises, or visible damage.
- Air Exchange: Ensure the area around the unit is not obstructed to allow for proper air circulation for the water-cooled motor.
6.2. Čišćenje senzora
Over time, sediment may accumulate and affect the flow sensors. The E.SYBOX comes with a tool for cleaning these sensors.
- Isključite napajanje: Always disconnect the unit from the power supply before any maintenance.
- Locate Sensors: Refer to the detailed diagram in the full technical manual (if available) to locate the flow sensors.
- Čisti: Use the provided tool to carefully clean any accumulated sediment from the sensors.
- Ponovo poveži: Ponovo sastavite sve uklonjene dijelove i ponovo priključite napajanje.
6.3. Priprema za zimu
If the unit is installed in an area subject to freezing temperatures, it must be drained to prevent damage.
- Isključite napajanje.
- Drain all water from the pump and associated piping.
- Store in a frost-free environment if possible, or ensure complete drainage.
7. Otkrivanje problema
This section addresses common issues you might encounter with your E.SYBOX system.
| Problem | Mogući uzrok | Rješenje |
|---|---|---|
| No water flow / Pump not starting | No power; Air in pump; Clogged inlet; Low water level in source. | Check power connection; Prime the pump; Clean inlet filter; Ensure adequate water supply. |
| Nizak pritisak | Incorrect pressure setting; Partially clogged filter/pipes; Air in system. | Adjust pressure setting on LCD; Inspect and clean filters/pipes; Bleed air from system. |
| Pump runs continuously / Frequent on/off cycling | Leak in system; Small continuous flow (e.g., dripping faucet); Faulty sensor. | Check for leaks in plumbing; Address small continuous flows; Contact support if sensor is suspected. |
| Neobična buka ili vibracija | Air in pump; Loose connections; Foreign object in pump. | Prime the pump; Check and tighten all connections; Disconnect power and inspect pump impeller (if safe and accessible). |
| LCD display error message | Specifična sistemska greška. | Note the error code and consult the full technical manual or contact customer support. |
Ako problem i dalje postoji nakon isprobavanja ovih rješenja, obratite se korisničkoj podršci.
8. Specifikacije
| Feature | Detalj |
|---|---|
| Model | 60161182 |
| Voltage | 230 Volts |
| Izvor napajanja | AC/DC |
| Maksimalni protok | 32 galona u minuti (GPM) |
| Maksimalna visina podizanja (glava) | 210 stopa |
| Raspon temperature tekućine | +32 to +95°F (domestic use), +32 to +102°F (other uses) |
| Maksimalna dubina usisavanja | 26 stopa |
| Težina artikla | 57 funti |
| Dimenzije proizvoda (D x Š x V) | 14.25 x 10.35 x 22.2 inča |
| Materijal | ABS |
| Integrated Expansion Tank | 0.5 galona |
9. Garancija i podrška
9.1. Informacije o garanciji
DAB provides a limited warranty for the E.SYBOX 230V Water Booster System against defects in materials and workmanship under normal use and service. The specific duration and terms of the warranty may vary by region and purchase date. Please retain your proof of purchase for warranty claims.
For detailed warranty terms and conditions, refer to the warranty card included with your product or visit the official DAB website.
9.2. Korisnička podrška
If you require technical assistance, have questions about installation, operation, or maintenance, or need to report a problem, please contact DAB customer support.
- Online podrška: Visit the official DAB Pumps website for FAQs, technical documents, and contact forms.
- Telefonska podrška: Refer to the contact information provided on the DAB website or your product packaging for regional support numbers.
- When contacting support, please have your product model (60161182) and serial number (if applicable) ready.