Dinuy terminal micro 5

Dinuy Terminal Micro 5 Digital Time Switch User Manual

Model: Terminal Micro 5

Brand: Dinuy

1. Uvod

This manual provides comprehensive instructions for the installation, operation, and maintenance of your Dinuy Terminal Micro 5 Digital Time Switch. Please read this manual carefully before using the device to ensure safe and efficient operation. This device is designed to control electrical circuits based on programmed time schedules.

2. Važne informacije o sigurnosti

  • Električna opasnost: Installation and maintenance should only be performed by a qualified electrician in accordance with all local and national electrical codes.
  • Disconnect power at the main circuit breaker before installing or servicing the device.
  • Ne izlažite uređaj vlazi, ekstremnim temperaturama ili korozivnim okruženjima.
  • Osigurajte da su svi priključci sigurni i pravilno izolirani kako biste spriječili kratki spoj.
  • Do not exceed the maximum load capacity specified for the device.

3. Proizvod je gotovview

The Dinuy Terminal Micro 5 is a compact digital time switch designed for DIN rail mounting. It features a clear LCD display for time and program status, along with intuitive buttons for easy programming.

Dinuy Terminal Micro 5 digital time switch, front view showing display, buttons, and wiring terminals.

Figure 1: Dinuy Terminal Micro 5 Digital Time Switch

This image displays the Dinuy Terminal Micro 5 digital time switch. The device is white, designed for DIN rail mounting. The top section shows terminals labeled '1' and '2' for power input. Below this, there are terminals '1', '2', '3' for the switched output, with a rating of 'μ16(6)A 250V~'. The central part features a digital LCD screen displaying 'DINUY', '18.06.18', 'LUNES' (Monday), 'On', and '9:28.00'. Below the screen are four blue buttons: 'M' (Mode), 'OK', '-' (Minus/Left arrow), and '+' (Plus/Right arrow). The bottom section shows terminals 'N' (Neutral) and 'L' (Live) for the main power supply, with '230V/50-60Hz' indicated.

3.1. Komponente

  • LCD ekran: Shows current time, day, program status, and programming menus.
  • 'M' Button (Mode): Used to navigate through different modes (e.g., time setting, program setting).
  • 'OK' Button: Potvrđuje odabire i postavke.
  • '-' Button (Minus/Left Arrow): Decreases values or moves left in menus.
  • '+' Button (Plus/Right Arrow): Increases values or moves right in menus.
  • Terminals L & N: Main power supply input (230V/50-60Hz).
  • Terminali 1, 2, 3: Switched output contacts (μ16(6)A 250V~).

4. Instalacija i podešavanje

4.1. Montaža

The Dinuy Terminal Micro 5 is designed for DIN rail mounting. Snap the device onto a standard 35mm DIN rail in your electrical panel.

4.2. Dijagram ožičenja

WARNING: Ensure power is disconnected before wiring.

  1. Connect the main Live (L) wire to the 'L' terminal at the bottom of the device.
  2. Connect the main Neutral (N) wire to the 'N' terminal at the bottom of the device.
  3. For the switched output, connect the load's Live wire to terminal '1' or '3' (depending on desired contact type, typically '1' for normally open).
  4. Connect the incoming Live wire for the load to terminal '2'.
  5. Refer to the markings on the device for precise terminal identification: Input power (L, N) and Switched output (1, 2, 3).

4.3. Početno uključivanje

After wiring, restore power. The display should illuminate. If the display is blank, check power connections. The device may require initial time and date setting.

5. Uputstvo za upotrebu

5.1. Podešavanje trenutnog vremena i dana

  1. Press the 'M' button repeatedly until the time setting mode is displayed (e.g., flashing hours).
  2. Use the '+' and '-' buttons to adjust the hour. Press 'OK' to confirm.
  3. Repeat for minutes, then for the current day of the week.
  4. Press 'OK' to save and exit the time setting mode.

5.2. Programiranje rasporeda uključivanja/isključivanja

The device allows setting multiple ON/OFF programs for different days or groups of days.

  1. Press the 'M' button until 'PROG' or a similar indicator appears.
  2. Use '+' or '-' to select a program number (e.g., '1 ON'). Press 'OK'.
  3. Set the desired ON time (hour and minute) using '+' and '-' and confirming with 'OK'.
  4. Select the days for this program (e.g., Mon-Fri, daily, specific days) using '+' and '-' and confirming with 'OK'.
  5. Repeat for the corresponding OFF time ('1 OFF').
  6. Continue for additional programs as needed.
  7. Press 'M' to exit programming mode and return to normal operation.

5.3. Ručno prebacivanje

To temporarily override the programmed schedule, press the 'M' button briefly during normal operation. This will cycle through 'ON', 'OFF', and 'AUTO' modes. Select 'AUTO' to resume programmed operation.

6. Održavanje

The Dinuy Terminal Micro 5 requires minimal maintenance. Ensure the device is kept clean and free from dust. Use a soft, dry cloth for cleaning. Do not use abrasive cleaners or solvents.

7. Otkrivanje problema

  • Uređaj se ne uključuje: Check main power supply and wiring connections (L and N terminals). Ensure the circuit breaker is on.
  • Opterećenje se ne prebacuje: Verify that the program is correctly set and the device is in 'AUTO' mode. Check the load's wiring and functionality. Ensure the load does not exceed the device's maximum switching capacity.
  • Netačan prikaz vremena: Reset the current time and day as per section 5.1.
  • Programi se ne izvršavaju: Ensure the device is in 'AUTO' mode. Recheck program settings for correct ON/OFF times and selected days.

8. Tehničke specifikacije

FeatureSpecifikacija
ProizvođačDinuy
ID proizvoda proizvođačaIH TER MC5
Broj modelaterminal micro 5
Ulazni voltage230V AC, 50-60Hz
Preklopni kapacitetμ16(6)A 250V~
Vrsta montažeDIN šina
Dimenzije paketa11.2 x 6.8 x 5 cm
Težina proizvoda100 g

9. Informacije o garanciji

This product is covered by the manufacturer's standard warranty. Please refer to the warranty card included with your purchase or contact Dinuy customer support for detailed warranty terms and conditions. Keep your proof of purchase for warranty claims.

10. Korisnička podrška

For technical assistance, troubleshooting not covered in this manual, or warranty inquiries, please contact your local Dinuy distributor or visit the official Dinuy webstranica za kontakt informacije.

Povezani dokumenti - terminal micro 5

Preview Manual de Interruptores Horarios Modulares Digitales DINUY IH TER MC/TEB MC
Manual de usuario completo para los interruptores horarios modulares digitales DINUY IH TER MC0, IH TEB MC0, IH TER MC2 e IH TEB MC2, cubriendo instalación, programación y características vía NFC.
Preview Manual de Instrucciones para Interruptores Horarios Modulares DINUY Serie BIMO
Instrucciones detalladas y especificaciones técnicas para los interruptores horarios modulares DINUY Serie BIMO (modelos IH BIM T, IH BIB T, IH BIM QT, IH BIM Q12), cubriendo operación, programación, configuración y cableado.
Preview DINUY IHEMT 1328 Timer Switch User Manual
User manual for the DINUY IHEMT 1328 timer switch, providing operating instructions, installation guidelines, and connection diagrams in multiple languages.
Preview DINUY Privremeni taktilni taster - Uputstvo za instalaciju i upotrebu
Sveobuhvatan priručnik za DINUY-jev privremeni taktilni taster, koji obuhvata instalaciju, tehničke specifikacije i rad za modele kao što su PT EMP EL4, PT SUP EL4 i PT GAR EL1.
Preview DINUY CI Series Electrical Bell Installation Guide
Concise installation guide for DINUY CI Series electrical bells (CI 100 220, CI 150 220, CI 200 220). Features multilingual instructions and wiring diagrams for easy setup.
Preview DINUY EM MIN 001 Wireless Transmitter for Pushbutton - User Manual
Technical specifications, installation guide, operation modes, and learning instructions for the DINUY EM MIN 001 wireless pushbutton transmitter. Includes battery replacement and conformity declaration.