PerfectPrime GA0080

PerfectPrime GA0080 Portable Gas Leak Detector User Manual

Model: GA0080

1. Uvod

The PerfectPrime GA0080 is a portable gas leak detector designed to identify the presence of natural gas (NG), methane, propane, and butane. This device utilizes a catalytic method gas sensor to provide a quick and reliable indication of gas leaks, enhancing safety in residential and commercial environments. It features a visible LED alarm system and a clear display for gas concentration readings.

2. Važne informacije o sigurnosti

Please read all instructions carefully before using the PerfectPrime GA0080. Failure to follow these instructions may result in inaccurate readings, property damage, or personal injury.

3. Sadržaj paketa

Provjerite da li se sve stavke nalaze u vašem paketu:

4. Proizvod je gotovview

Familiarize yourself with the components of your GA0080 gas leak detector.

PerfectPrime GA0080 Portable Gas Leak Detector, showing the display and power button.

Slika 4.1: Sveukupno view of the PerfectPrime GA0080 Portable Gas Leak Detector, highlighting the digital display and power button.

PerfectPrime GA0080 Gas Leak Detector sensor end with ventilation holes.

Slika 4.2: Close-up of the sensor end of the GA0080, showing the protective grille and ventilation holes for gas detection.

PerfectPrime GA0080 Gas Leak Detector with three LED indicators: green, yellow, and red.

Slika 4.3: Side view of the GA0080, illustrating the three LED indicators (green, yellow, red) for visual alarm signals.

5. Podešavanje

5.1 Instalacija baterije

  1. Pronađite poklopac odjeljka za bateriju na stražnjoj strani uređaja.
  2. Pomaknite ili otkačite poklopac da biste otvorili pretinac.
  3. Insert two (2) AA 1.5V batteries, ensuring correct polarity (+/-).
  4. Čvrsto zatvorite poklopac odeljka za baterije.

Note: Always use fresh batteries for optimal performance. Remove batteries if the device will not be used for an extended period.

6. Operacija

6.1 Uključivanje i zagrijavanje

  1. Pritisnite i držite dugme za napajanje dok se uređaj ne uključi.
  2. The device will enter a warm-up phase, which takes approximately 200 seconds. During this time, the display may show a countdown or "Warm Up".
  3. Once warm-up is complete, the device is ready for use, and the display will show "0 ppm" or a low background reading.

6.2 Detecting Gas Leaks

6.3 Isključivanje

Press and hold the Power button until the device turns off.

7. Održavanje

8. Otkrivanje problema

ProblemMogući uzrokRješenje
Uređaj se ne uključuje.Prazne ili nepravilno instalirane baterije.Replace batteries with new AA 1.5V batteries, ensuring correct polarity.
Netačna ili nedosljedna očitanja.Sensor not fully warmed up; sensor contamination; low battery.Allow full warm-up time (200 seconds). Ensure sensor head is clean. Replace batteries.
Device constantly alarms in a clean environment.High background gas levels; sensor malfunction.Move to a well-ventilated area to check if the alarm stops. If the issue persists, contact customer support.
No alarm when gas is present.Gas concentration below alarm threshold; device malfunction.Ensure gas concentration is sufficient to trigger an alarm (2% LEL for yellow, 10% LEL for red). Test with a known gas source if safe to do so. Contact customer support if malfunction is suspected.

9. Specifikacije

Detekcijski plinoviNatural Gas (NG), Methane, Propane, Butane
Tip senzoraCatalytic Method Gas Sensor
Vrijeme zagrijavanjaU roku od 200 sekundi
Domet detekcije0 ~ 9999 ppm
Rezolucija100 ppm
Alarmna LEDThree colors (Green, Yellow, Red)
Alarmni pragoviYellow LED: ~2% LEL; Red LED: ~10% LEL
Zvučni alarm2.713kHz / 100ms
Radna temperatura-20°C ~ 70°C (-4°F ~ 158°F)
Radna vlažnostManje od 90% RH
Izvor napajanja2 x AA 1.5V baterije (nisu uključene)
Dimenzije (D x Š x V)220 x 20 x 20 mm (8.66" x 0.79" x 0.79")
TežinaPribl. 80 g (2.82 oz)

10. Garancija i podrška

For warranty information or technical support, please contact PerfectPrime customer service. Refer to the product packaging or the official PerfectPrime webstranicu za najnovije kontakt podatke.

Webstranica: www.perfectprime.com

Povezani dokumenti - GA0080

Preview Digitalni manometar PerfectPrime AR168 Uputstvo za upotrebu
Instruction manual for the PerfectPrime AR168 Digital Pressure Gauge, covering product introduction, basic functions, technical performance, measurement ranges, symbol definitions, button operations, precautions, and additional information.
Preview PerfectPrime TC0520 USB Interface Protocol Guide
A comprehensive guide to the USB interface protocol for the PerfectPrime TC0520 datalogger thermometer, detailing commands, data output, and error checking.
Preview PerfectPrime TC0580 Thermocouple Temperature Data Logger Instruction Manual
This instruction manual provides comprehensive guidance on the PerfectPrime TC0580 Thermocouple Temperature Data Logger. It covers product features, specifications, software installation, device operation, data logging, viewing, exporting, and troubleshooting.