PerfectPrime TL0700

Perfect-Prime TL0700 K-Type Sensor Probe Instruction Manual

Model: TL0700 | Brand: PerfectPrime

1. Uvod

This instruction manual provides essential information for the proper use, setup, and maintenance of your Perfect-Prime TL0700 K-Type Sensor Probe. Please read this manual thoroughly before using the product to ensure accurate measurements and safe operation. Retain this manual for future reference.

Banner displaying 'THERMOCOUPLE PROBE Your Intelligent Choice Probes & Sensors'

Slika 1.1: General prekoview of thermocouple probes and sensors.

2. Proizvod je gotovview i karakteristike

The Perfect-Prime TL0700 is a K-Type thermocouple sensor probe designed for precise temperature measurements across a wide range. It is compatible with various K-Type thermocouple thermometers and meters.

Ključne karakteristike:

  • Raspon radne temperature: -30 °C do 700 °C (-22 °F do 1292 °F)
  • Dužina sonde: 100 cm (1 Meter)
  • Sensor and Wire Material: USA Thermocouple Sensor and Wire with Glass Braid Insulation
  • Prečnik žice: 0.5 mm x 2
  • Package Diameter: Približno 3 mm
  • Tip konektora: Flat Shape Male K-Type Connector
Perfect-Prime TL0700 K-Type Sensor Probe with coiled wire and yellow flat male connector

Image 2.1: The Perfect-Prime TL0700 K-Type Sensor Probe, showing the coiled wire and the yellow flat male connector.

3. Podešavanje

Follow these steps to properly set up your TL0700 K-Type Sensor Probe:

  1. Inspect the Probe: Before each use, visually inspect the probe wire and connector for any signs of damage, fraying, or corrosion. Do not use if damage is observed.
  2. Identifikujte konektor: The TL0700 probe features a standard flat shape male K-Type connector, typically colored yellow.
  3. Connect to Thermometer: Insert the male connector of the TL0700 probe into the corresponding female K-Type input port on your compatible thermometer or meter. Ensure a firm and secure connection. The polarity of K-Type connectors is standardized, but always ensure the pins align correctly.
  4. Uključeno: Turn on your K-Type thermometer/meter according to its specific instructions.
Close-up of the yellow flat male K-Type connector of the sensor probe

Slika 3.1: Detaljno view of the K-Type flat male connector, highlighting its design for secure connection.

A digital K-Type thermometer displaying multiple temperature readings with four probes connected

Slika 3.2: Primjerample of a K-Type thermometer with multiple probes connected, illustrating typical usage.

4. Uputstvo za upotrebu

Once the TL0700 probe is securely connected to your K-Type thermometer, you can begin taking temperature measurements:

  1. plasman: Carefully position the tip of the sensor probe at the point where you wish to measure the temperature. Ensure good thermal contact with the object or medium.
  2. stabilizacija: Allow a few moments for the temperature reading on your thermometer to stabilize. The response time for this probe is approximately 500 milliseconds, but stabilization time may vary depending on the thermal mass of the object being measured and the thermometer's processing speed.
  3. Očitavanje mjerenja: Read the temperature displayed on your thermometer.
  4. Raspon temperature: Ensure that the measured temperature falls within the probe's specified operating range of -30 °C to 700 °C (-22 °F to 1292 °F). Exceeding this range can damage the probe.

Napomena: The accuracy of the measurement depends on both the probe and the connected thermometer. Refer to your thermometer's manual for its specific accuracy specifications and calibration procedures.

5. Održavanje

Proper maintenance ensures the longevity and accuracy of your TL0700 K-Type Sensor Probe:

  • čišćenje: After each use, especially when measuring in corrosive or dirty environments, gently wipe the probe tip and wire with a clean, damp cloth. For stubborn residues, use a mild, non-abrasive cleaner. Ensure the probe is completely dry before storage.
  • Skladištenje: Store the probe in a clean, dry environment, away from extreme temperatures, direct sunlight, and corrosive chemicals. Avoid kinking or sharply bending the wire, as this can damage the internal conductors and insulation.
  • inspekcija: Regularly inspect the probe for any physical damage, such as cuts in the insulation, exposed wires, or bent connector pins. Replace the probe if any damage is detected to prevent inaccurate readings or electrical hazards.

6. Otkrivanje problema

If you encounter issues with your TL0700 K-Type Sensor Probe, consider the following:

  • Nema očitavanja ili su očitavanja nepravilna:
    • Ensure the probe is securely connected to the thermometer.
    • Check if the thermometer is set to the correct K-Type input mode.
    • Inspect the probe wire and connector for damage. A damaged probe may need replacement.
    • Verify that the thermometer itself is functioning correctly by testing with another known good K-Type probe if available.
  • Netačna očitavanja:
    • Ensure good thermal contact between the probe tip and the object being measured.
    • Allow sufficient time for the reading to stabilize.
    • Confirm that the measured temperature is within the probe's specified operating range.
    • Consider if the probe needs calibration, or if the thermometer requires calibration.

7. Specifikacije

SpecifikacijaVrijednost
Raspon radne temperature-30 °C do 700 °C (-22 °F do 1292 °F)
Duljina sonde100 cm (1 Meter)
Wire Diameter0.5 mm x 2
Package Diameter~ 3 mm
Tip konektoraFlat Shape Male K-Type
Vrijeme odgovora500 milisekundi
ProizvođačPerfect Prime
Broj modela artiklaCOMINHKPR131550
UPC638414477455
Dimenzije paketa12.9 x 12.7 x 0.99 cm; 31.75 grama
Banner showing various PerfectPrime probes and thermometers, stating compatibility with all branded or non-branded products

Image 7.1: PerfectPrime probes are compatible with various branded and non-branded products.

8. Garancija i podrška

For specific warranty information regarding your Perfect-Prime TL0700 K-Type Sensor Probe, please refer to the documentation included with your purchase or visit the official PerfectPrime webstranica. Uslovi garancije mogu se razlikovati u zavisnosti od regije i prodavca.

If you require technical assistance, have questions about product functionality, or need to report an issue, please contact PerfectPrime customer support through their official channels. Contact information can typically be found on the manufacturer's webweb stranici ili na ambalaži vašeg proizvoda.

Povezani dokumenti - TL0700

Preview PerfectPrime TC0580 Thermocouple Temperature Data Logger Instruction Manual
This instruction manual provides comprehensive guidance on the PerfectPrime TC0580 Thermocouple Temperature Data Logger. It covers product features, specifications, software installation, device operation, data logging, viewing, exporting, and troubleshooting.
Preview Digitalni manometar PerfectPrime AR168 Uputstvo za upotrebu
Instruction manual for the PerfectPrime AR168 Digital Pressure Gauge, covering product introduction, basic functions, technical performance, measurement ranges, symbol definitions, button operations, precautions, and additional information.
Preview PerfectPrime TC0520 USB Interface Protocol Guide
A comprehensive guide to the USB interface protocol for the PerfectPrime TC0520 datalogger thermometer, detailing commands, data output, and error checking.