1. Uvod

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your AERMEC OMNIA UL Series Fan Coil Unit, model UL16C+ZU. This fan convector is designed for both heating and cooling applications, featuring an electronic thermostat for precise temperature and speed control. Please read this manual thoroughly before using the product and retain it for future reference.

The AERMEC OMNIA UL16C+ZU is a versatile unit suitable for floor installation, capable of operating at low temperatures for heating (e.g., 50°C instead of 70°C) and providing effective air conditioning. It comes with a roof cabinet (sheath) in white RAL 9002 and clogs in RAL 7044.

2. Sigurnosne informacije

  • Always disconnect the unit from the power supply before performing any maintenance or cleaning.
  • Installation and repairs must be carried out by qualified personnel only, in accordance with local regulations and standards.
  • Osigurajte napajanje voltage matches the specifications indicated on the unit's rating label.
  • Do not block the air intake or outlet grilles.
  • Držite djecu i kućne ljubimce dalje od uređaja tokom rada.
  • Ne ubacujte predmete u uređaj.
  • Ako je kabel za napajanje oštećen, mora ga zamijeniti proizvođač, njegov serviser ili slično kvalifikovane osobe kako bi se izbjegla opasnost.

3. Proizvod je gotovview

The AERMEC OMNIA UL16C+ZU fan coil unit is designed for efficient climate control. Key features include:

  • UL-srx140m: Suitable for both horizontal and vertical construction.
  • C: Version with Thermostat: Equipped with an electronic thermostat for precise control.
  • Čišćenje ventilatora: Designed for easy fan cleaning access.
  • Condensation Tub: Features a tub for condensation collection that requires periodic cleaning.
  • Višenamjenska instalacija: Hydraulic taps can be installed on either the left or right side.
AERMEC OMNIA UL Series Fan Coil Unit

Figure 1: AERMEC OMNIA UL Series Fan Coil Unit (Model UL16C+ZU)

Ova slika prikazuje prednju stranu view of the AERMEC OMNIA UL Series Fan Coil Unit, showcasing its compact design and white finish, suitable for floor installation.

4. Postavljanje i instalacija

The AERMEC OMNIA UL16C+ZU is designed for floor-mounted installation. Ensure the installation location provides adequate space for air circulation and maintenance access.

  1. Raspakivanje: Carefully remove the unit from its packaging. Inspect for any damage incurred during transit.
  2. Pozicioniranje: Place the unit on a stable, level surface. The unit is supplied with a roof cabinet (sheath) and clogs for complete floor installation.
  3. Hidraulički priključci: The hydraulic taps can be installed on either the left or right side of the unit. Consult a qualified plumber for proper connection to your heating/cooling system. Ensure all connections are secure and leak-free.
  4. Električni priključci: Connect the unit to a suitable electrical supply. This unit operates on electric current. All electrical work must be performed by a qualified electrician in accordance with local electrical codes.
  5. Priključak termostata: The unit includes an electronic thermostat. Ensure it is correctly wired and configured according to the specific wiring diagram provided with the unit (not detailed in this general manual).
AERMEC OMNIA UL Series Installation Diagram

Figure 2: Installation Diagram for AERMEC OMNIA UL Series

This diagram illustrates typical installation configurations for the AERMEC OMNIA UL Series, showing options for wall and floor mounting, and the general layout of connections.

AERMEC OMNIA UL Series Dimensions

Figure 3: Dimensions of AERMEC OMNIA UL Series

This image provides detailed dimensional drawings for various OMNIA UL models, including length, height, depth, and weight, crucial for planning installation space.

5. Uputstvo za upotrebu

Your AERMEC OMNIA UL16C+ZU fan coil unit is equipped with an electronic thermostat for user-friendly control.

  • Uključivanje/isključivanje: Use the main power switch (if present) or the thermostat control to turn the unit on or off.
  • Podešavanje temperature: Use the controls on the electronic thermostat to set your desired room temperature. The unit will automatically adjust its operation to maintain this setting.
  • Operating Modes (Heating/Cooling): The unit can function in both heating and cooling modes. Select the appropriate mode via the thermostat interface. The unit is efficient for heating at lower water temperatures (e.g., 50°C).
  • Kontrola brzine ventilatora: The electronic thermostat also allows you to adjust the fan speed. Choose a lower speed for quieter operation or a higher speed for faster temperature changes.

Refer to the specific instructions provided with your electronic thermostat for detailed operation of its features and settings.

6. Održavanje

Regular maintenance ensures optimal performance and longevity of your fan coil unit. Always disconnect power before maintenance.

  • Čišćenje ventilatora: Periodically clean the fan blades to prevent dust accumulation, which can reduce efficiency and airflow. Access the fan compartment as per the unit's design (refer to specific diagrams if available).
  • Condensation Tub Cleaning: The tub for condensation should be cleaned regularly to prevent blockages and the growth of mold or bacteria. Ensure the drain is clear.
  • Čišćenje/zamjena filtera: While not explicitly listed, most fan coil units have air filters. Check your unit for filters and clean or replace them as recommended by AERMEC to maintain air quality and unit efficiency.
  • Eksterijerno čišćenje: Obrišite vanjske površine mekom krpom, damp tkanina. Nemojte koristiti abrazivna sredstva za čišćenje ili rastvarače.

7. Otkrivanje problema

If you encounter issues with your AERMEC OMNIA UL16C+ZU, consider the following basic troubleshooting steps:

  • Jedinica se ne uključuje:
    • Check if the unit is properly plugged into a power outlet.
    • Provjerite da li je prekidač strujnog kruga isključen.
    • Ensure the thermostat is set to an active mode and desired temperature.
  • Nedovoljno grijanje/hlađenje:
    • Check if the air filters are clean and not obstructed.
    • Pazite da rešetke za usis i izlaz zraka nisu blokirane.
    • Verify the thermostat settings are appropriate for the desired temperature.
    • Confirm that the hydraulic system is functioning correctly and water is circulating.
  • Neobična buka:
    • Check for loose components or debris inside the unit.
    • Uvjerite se da je jedinica ravna i stabilna.

If problems persist after performing these checks, contact a qualified service technician for assistance.

8. Specifikacije

FeatureDetalj
BrandAERMEC
Broj modelaUL16C+ZU
BojaWhite Ral9002 Feet Ral7044
Dimenzije proizvoda75 x 51.3 x 17.3 cm
Težina artikla28 kg
MaterijalPlastika
Posebne karakteristikeElectronic thermostat for regulating speed and room temperature
Dizajn električnog ventilatoraPodni ventilator
Izvor napajanjaElektrična struja
StilModerna
Vrsta sobeBathroom (also suitable for other rooms)
Preporučena upotrebaCooling, Ventilating, Heating
Vrsta montažeFloor Mounted
ASINB01MTW5F82
Datum prve dostupnosti16. maja 2017

9. Garancija i podrška

For warranty information and technical support, please refer to the documentation provided with your purchase or contact AERMEC customer service directly. Keep your proof of purchase for warranty claims.

Manufacturer: aermec

Contact information for AERMEC can typically be found on their official webweb-mjestu ili na ambalaži proizvoda.

Povezani dokumenti - UL16C+ZU

Preview AERMEC Omnia Radiant Fan Coils: Tehnički priručnik i specifikacije
Sveobuhvatni tehnički priručnik za AERMEC Omnia Radiant ventilatorske konvektori (serija UL_R, UL_RI), s detaljnim karakteristikama, specifikacijama, načinima rada, instalacijom i podacima o performansama.
Preview AERMEC Omnia UL C Fan Coil: User and Installation Manual
Comprehensive user and installation manual for the AERMEC Omnia UL C fan coil unit, covering product description, operation, controls, installation, maintenance, troubleshooting, dimensions, wiring diagrams, and warranty information.
Preview AERMEC ZH serija nožica/baza ventilatorskih konvektora - Vodič za instalaciju
Zvanični vodič za instalaciju AERMEC ZH 1, ZH 1M, ZH 1B i ZH 1BM stopala i podnožja dizajniranih za OMNIA HL i OMNIA HL M ventilokonvektorske jedinice. Uključuje detalje o proizvodu, korake instalacije i sigurnosna upozorenja.
Preview Aermec VCH trokraki ventil za OMNIA ventilatorske konvektori - Tehnički podaci i instalacija
Tehničke specifikacije, vodič za instalaciju i dijagram ožičenja za Aermec VCH trokraki ventil koji se koristi s ventilatorskim konvektorima serije OMNIA HL i UL.
Preview Aermec FCZ Fan Coil: Universal and Floor Installation Guide
Comprehensive guide to the Aermec FCZ fan coil series, detailing features, versions, accessories, and technical specifications for universal and floor installation. Includes performance data and dimensions.
Preview Aermec Omnia UL N ventilatorski konvektor: Uputstvo za instalaciju i upotrebu
Sveobuhvatan vodič za Aermec Omnia UL N ventilatorsku konvekciju, koji obuhvata instalaciju, rad, održavanje, rješavanje problema i tehničke specifikacije. Naučite kako efikasno koristiti i instalirati svoju Aermec ventilatorsku konvekciju.