Arista Networks DCS-7050S-52-R

Arista Networks DCS-7050S-52-R 7050 Series Switch User Manual

Model: DCS-7050S-52-R

1. Uvod

This manual provides essential information for the installation, operation, and maintenance of the Arista Networks DCS-7050S-52-R 7050 Series Switch. This high-performance switch features 52 SFP+ ports, rear-to-front airflow, and dual 460W AC power supplies, designed for demanding network environments.

Please read this manual thoroughly before attempting to install or operate the device. Retain this manual for future reference.

Sigurnosne informacije

Always observe standard safety precautions when working with electrical equipment. Ensure proper grounding and ventilation. Only qualified personnel should perform installation and maintenance procedures. Disconnect power before servicing.

2. Postavljanje i instalacija

2.1 Raspakivanje prekidača

Carefully remove the switch and all accessories from the packaging. Verify that all components listed in the packing list are present and undamaged. Report any missing or damaged items to your supplier immediately.

2.2 Fizička instalacija

The DCS-7050S-52-R switch is designed for rack mounting. Ensure the rack is stable and properly grounded. This model features rear-to-front airflow, meaning cool air enters from the rear of the chassis and exits through the front. Ensure adequate clearance for airflow at both the front and rear of the switch.

Arista Networks DCS-7050S-52-R Switch Front View

Slika 1: Front view of the Arista Networks DCS-7050S-52-R switch, showing the SFP+ ports and status indicators. This image illustrates the port layout and general appearance of the device.

2.3 Priključak za napajanje

The switch is equipped with dual 460W AC power supplies for redundancy. Connect the provided 2XC13-C14 power cords to the AC inlets on the rear of the switch and then to separate, grounded AC power sources. It is recommended to connect to different power circuits for maximum redundancy.

  • Ensure power sources match the switch's input voltage zahtjeve.
  • Connect both power supplies for redundant operation.

2.4 Mrežne veze

The DCS-7050S-52-R features 52 SFP+ porta. Insert compatible SFP+ transceivers into the desired ports. Connect appropriate fiber optic or direct attach copper (DAC) cables to the transceivers. Ensure proper cable management to avoid strain on the ports.

2.5 Početno uključivanje

After all physical connections are made, power on the switch. Observe the system status LEDs for initial boot-up sequence. Refer to the LED indicators section for status interpretation.

3. Uputstvo za upotrebu

3.1 Uključivanje/isključivanje napajanja

To power on, ensure power cords are connected. The switch will automatically power on. To power off, disconnect both power cords from their sources. For graceful shutdown, it is recommended to use the operating system commands before disconnecting power.

3.2 Pristup upravljačkom interfejsu

The switch can be managed via a console port (RJ-45), out-of-band management (OOB) Ethernet port, or in-band management through one of the SFP+ data ports. Connect a console cable to the console port and use a terminal emulator (e.g., PuTTY, Tera Term) with settings: 9600 baud, 8 data bits, no parity, 1 stop bit, no flow control.

3.3 Arista EOS Overview

The Arista DCS-7050S-52-R runs Arista EOS (Extensible Operating System). EOS provides a command-line interface (CLI) for configuration and monitoring. For detailed configuration instructions, refer to the official Arista EOS documentation available on the Arista Networks website.

3.4 SFP+ Port Operation

The 52 SFP+ ports support 10 Gigabit Ethernet connectivity. Ensure that compatible SFP+ transceivers are used for the desired link type (e.g., SR, LR, DAC). Port status LEDs indicate link activity and speed.

4. Održavanje

4.1 Čišćenje

Periodically clean the exterior of the switch with a soft, dry, lint-free cloth. Ensure ventilation openings are free from dust and obstructions. Do not use liquid or aerosol cleaners directly on the switch.

4.2 Ažuriranja firmvera

Regularly check the Arista Networks support website for the latest EOS firmware updates. Follow the provided instructions for safe and effective firmware upgrades to ensure optimal performance and security.

4.3 Zamjena komponenti

The DCS-7050S-52-R is designed with hot-swappable components such as fan trays and power supplies. Refer to the Arista Networks hardware guide for specific instructions on replacing these components while the switch is operational.

5. Otkrivanje problema

This section provides basic troubleshooting steps for common issues. For more complex problems, consult the Arista Networks support resources.

5.1 LED indikatori

Observe the status LEDs on the front panel for diagnostic information:

  • Sistemska LED dioda: Indicates overall system health (e.g., green for normal, amber for warning, red for critical).
  • Power Supply LEDs: Indicate the status of each power supply.
  • Fan LEDs: Indicate the status of the fan trays.
  • LED diode porta: Indicate link status and activity for each SFP+ port.

Refer to the Arista Networks documentation for a detailed explanation of all LED states.

5.2 Uobičajeni problemi

  • Nema napajanja: Verify power cord connections, power source, and power supply LEDs.
  • Nema veze na portu: Check transceiver compatibility, cable integrity, and connection to the peer device. Verify port configuration.
  • Kvar sistema: Check system LED. If red, consult logs via console or management interface.

5.3 Procedure resetovanja

A system reboot can often resolve minor issues. Use the appropriate EOS command for a graceful reboot. In cases where the system is unresponsive, a hard power cycle (disconnecting and reconnecting power) may be necessary, but this should be a last resort.

6. Specifikacije

FeatureOpis
Broj modelaDCS-7050S-52-R
ProizvođačArista
Interface TypeSFP+
Broj portova52
Smjer protoka zrakaOd pozadi prema naprijed
Power SuppliesDual 460W AC
Dimenzije proizvoda1 x 1 x 1 inča
Težina artikla2 funte
Gornja temperatura40 stepeni Celzijusa
Materijal kućištaMetal

7. Informacije o garanciji

This Arista Networks product is covered by a standard manufacturer's warranty. For detailed information regarding warranty terms, conditions, and duration, please refer to the warranty statement provided with your purchase or visit the official Arista Networks webSačuvajte dokaz o kupovini za slučaj reklamacije.

8. Tehnička podrška

For technical assistance, product documentation, and software downloads, please visit the Arista Networks support portal. You can find comprehensive resources, FAQs, and contact information for their technical support team.

  • Arista Networks Webstranica: www.arista.com
  • Portal podrške: Refer to the Arista website for specific support contact details and online resources.

Povezani dokumenti - DCS-7050S-52-R

Preview Arista Networks 7000 Serija 1 RU-Gen 2 Prekidači za podatkovne centre - Kratki vodič
Ovaj vodič pruža osnovne informacije za instalaciju i početno podešavanje Arista Networks 7000 serije 1 RU-Gen 2 preklopnika za podatkovne centre, uključujući modele DCS-7048T-A, DCS-7050Q-16, DCS-7050QX-32, DCS-7050S-52, DCS-7050S-64, DCS-7050T-36, DCS-7050T-52, DCS-7050T-64, DCS-7124FX, DCS-7124SX, DCS-7150S-24, DCS-7150S-52 i DCS-7150S-64.
Preview Vodič za brzi početak Arista 7050X4 serije preklopnika za podatkovne centre | Instalacija i podešavanje
Započnite s Arista Networks 7050X4 serijom podatkovnih centara. Ovaj vodič za brzi početak pokriva instalaciju, montažu u rack, kabliranje, sigurnost i početnu konfiguraciju za modele kao što su DCS-7050DX4-32S, DCS-7050PX4-32S i druge. Neophodan je za mrežne tehničare i servisno osoblje.
Preview Vodič za skup funkcija specifičnih za Arista platformu: ZTP, autentifikacija hardvera, sigurno pokretanje
Vodič koji detaljno opisuje podršku za specifične funkcije platforme kompanije Arista Networks za Zero Touch Provisioning (ZTP) sa CloudVision kao uslugom, autentifikaciju hardvera i sigurno pokretanje. Uključuje liste podržanih Arista SKU-ova prekidača i porodica proizvoda.
Preview Kratki vodič za korištenje Arista Networks 7280R3A serije preklopnika za podatkovne centre
Ovaj vodič za brzi početak kompanije Arista Networks pruža osnovne informacije za instalaciju i početno podešavanje preklopnika za podatkovne centre serije 7280R3A. Obuhvata raspakivanje, montažu u rack, kabliranje i osnovne korake konfiguracije za ove visokoperformansne mrežne uređaje.
Preview Vodič za hardver DANZ Monitoring Fabric | Arista Networks
Detaljne specifikacije hardvera, opisi komponenti i LED indikatori za Arista Networks DANZ Monitoring Fabric. Obuhvata čvorove kontrolera, servisa, analitike i snimanja, plus podržane Arista prekidače.
Preview Arista CloudEOS and vEOS Router Configuration Guide
A comprehensive guide detailing the configuration and deployment of Arista CloudEOS and vEOS Router software across various platforms including AWS, Azure, GCP, KVM, and ESXi, covering licensing, high availability, IPsec, DPDK, and appliance-specific setups.