1. Uvod
The ACI A/100KS-D-4"-PB Duct Temperature Sensor is a precision instrument designed for accurate temperature measurement within HVAC, building automation, and light industrial systems. This sensor utilizes a 100k ohm thermistor at 77°F (25°C) to provide reliable temperature data. Its robust design includes a plastic duct mount configuration with a mounting flange for easy installation and a foam pad to minimize vibration. The sensing element is double encapsulated to prevent moisture infiltration, ensuring long-term performance and reliability.
Typical applications for this sensor include zone control, air handling units, and general temperature monitoring within ductwork environments.
2. Sigurnosne informacije
Please read all instructions carefully before installation and operation. Failure to follow these instructions may result in equipment damage or personal injury.
- Disconnect all power to the system before installation or maintenance.
- Instalaciju treba izvršiti kvalificirano osoblje u skladu sa svim lokalnim i nacionalnim električnim propisima.
- Do not exceed the specified operating temperature or humidity ranges.
- Avoid exposing the sensor to corrosive chemicals or excessive mechanical stress.
- Osigurajte ispravno uzemljenje kako biste spriječili električne opasnosti.
3. Komponente i sadržaj paketa
Prije nego što nastavite s instalacijom, provjerite jesu li sve komponente prisutne i neoštećene.
- ACI A/100KS-D-4"-PB Duct Temperature Sensor (with integrated plastic enclosure and 4-inch probe)
- Mounting Screws (typically included, verify with packaging)

Figure 3.1: ACI A/100KS-D-4"-PB Duct Temperature Sensor. This image shows the ACI A/100KS-D-4"-PB Duct Temperature Sensor. It features a black plastic enclosure with a metal temperature probe extending upwards. The enclosure has a mounting flange and visible knockouts for wiring.
4. Postavljanje i instalacija
The ACI duct temperature sensor is designed for straightforward installation in ductwork.
4.1. Odabir lokacije
- Choose a location in the ductwork that provides a representative temperature reading of the air stream. Avoid areas directly downstream of coils, fans, or other heat sources/sinks that could skew readings.
- Ensure sufficient clearance for mounting the plastic enclosure and inserting the probe into the duct.
4.2. Montaža
- Drill a hole in the ductwork large enough to accommodate the 4-inch sensor probe.
- Position the sensor's mounting flange against the duct surface. The integrated foam pad on the enclosure helps dampen vibrations and provides a seal.
- Secure the enclosure to the duct using appropriate screws through the mounting holes on the flange.
4.3. Ožičenje
- Open the plastic enclosure.
- Route the necessary wiring through one of the knockouts provided on the enclosure.
- Connect the sensor wires to your building automation system or controller according to the system's wiring diagram. Refer to the specifications section for thermistor resistance values.
- Uvjerite se da su svi priključci sigurni i izolirani.
- Close the enclosure securely after wiring is complete.
5. Principi rada
The A/100KS-D-4"-PB sensor operates on the principle of thermistor resistance change with temperature. A thermistor is a type of resistor whose resistance is strongly dependent on temperature, more so than in standard resistors. As the ambient air temperature within the duct changes, the resistance of the 100k ohm thermistor element changes accordingly. Your building automation system or controller measures this resistance change and converts it into a temperature reading.
The double-encapsulated sensing element ensures that the thermistor remains protected from moisture, which is crucial for maintaining accuracy and longevity in duct environments.
6. Održavanje
The ACI Duct Temperature Sensor is designed for minimal maintenance. However, periodic checks can ensure optimal performance.
- Godišnja inspekcija: Godišnje pregledajte senzor i njegovo ožičenje na bilo kakve znakove fizičkog oštećenja, korozije ili labavih spojeva.
- čišćenje: If dust or debris accumulates on the probe or enclosure, gently wipe it clean with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Rekalibracija: While these sensors are generally stable, if significant discrepancies in temperature readings are observed, consult your building automation system's documentation for recalibration procedures or consider professional service.
7. Otkrivanje problema
Ovaj odjeljak pruža rješenja za uobičajene probleme s kojima se možete susresti.
| Problem | Mogući uzrok | Rješenje |
|---|---|---|
| No temperature reading or incorrect reading. | Slabo ožičenje. Sensor damaged. Incorrect wiring to controller. Controller input misconfigured. | Provjerite nepropusnost svih priključaka ožičenja. Inspect sensor for physical damage. If damaged, replace. Verify wiring against controller's specifications. Confirm controller input is set for a 100k ohm thermistor. |
| Temperature reading is consistently high/low. | Sensor located in an unrepresentative area. Calibration offset in controller. Sensor aging. | Relocate sensor to a more appropriate position in the duct. Check controller settings for any applied offsets and adjust if necessary. If sensor is old, consider replacement. |
| Povremena očitavanja. | Slaba veza. Interferencija. Moisture ingress (unlikely due to encapsulation). | Provjerite i osigurajte sve priključke ožičenja. Ensure wiring is routed away from sources of electrical interference. Inspect enclosure for signs of damage that could allow moisture. |
8. Specifikacije
| Atribut | Vrijednost |
|---|---|
| Model | A/100KS-D-4"-PB |
| Brand | ACI (Automation Components Inc.) |
| Tip senzora | Termistor |
| Otpor | 100k ohms @ 77°F (25°C) |
| Duljina sonde | 4 inča |
| Materijal kućišta | Plastika |
| Montaža | Duct Mount with Flange |
| Posebne karakteristike | Foam pad for vibration dampening, Double encapsulated sensing element |
| ASIN | B01M0V9CEK |
| Datum prve dostupnosti | 22. septembra 2016 |
9. Garancija i podrška
For specific warranty information, please refer to the documentation provided with your purchase or visit the official ACI website. ACI products are typically covered by a manufacturer's warranty against defects in materials and workmanship.
For technical support, troubleshooting assistance beyond this manual, or to inquire about replacement parts, please contact ACI customer service or your authorized distributor. Contact information can usually be found on the manufacturer's website or on your purchase invoice.
Proizvođač: Automation Components Inc. (ACI)
Webstranica: www.workaci.com (Npramplink, provjerite službenu stranicu)