1. Uvod
This manual provides essential information for the safe and efficient installation, operation, and maintenance of the EBARA LPD Type Line Pump, Model 25LPD5.15. Please read this manual thoroughly before using the product and keep it for future reference.
2. Sigurnosne informacije
Važna sigurnosna uputstva:
- Uvijek isključite napajanje prije bilo kakvog održavanja ili pregleda.
- Osigurajte ispravno uzemljenje kako biste spriječili strujni udar.
- Do not operate the pump with damaged wiring or components.
- Nosite odgovarajuću ličnu zaštitnu opremu (LZO) tokom instalacije i održavanja.
- Refer to local electrical codes and regulations for installation.
3. Proizvod je gotovview
The EBARA LPD Type Line Pump 25LPD5.15 is a compact and lightweight inline pump designed for various industrial and commercial applications. Its inline configuration allows for direct installation within existing piping systems, minimizing the required installation space. The design also facilitates easy disassembly and inspection without the need to remove the entire piping.
Ključne karakteristike:
- Kompaktan i lagan: Inline design saves space.
- Lako održavanje: Disassembly and inspection possible without removing piping.
- Svestrane primjene: Suitable for cold/hot water circulation, various machine sets, and general water supply.

Figure 1: EBARA LPD Type Line Pump 25LPD5.15. This image shows the compact, inline design of the pump, highlighting its integration capability within a piping system.
4. Postavljanje i instalacija
4.1 Raspakivanje i pregled
- Pažljivo izvadite pumpu iz ambalaže.
- Inspect the pump for any visible damage that may have occurred during transit.
- Provjerite da li su prisutne sve komponente navedene na listi za pakovanje.
4.2 Montaža
- The LPD type pump is designed for inline installation directly into the piping system.
- Ensure the mounting location is stable, level, and can support the weight of the pump and associated piping when filled with liquid.
- Allow sufficient space around the pump for ventilation and future maintenance access.
4.3 Priključci cijevi
- Connect the pump to the piping system, ensuring all connections are tight and leak-free.
- Use appropriate sealing materials for pipe threads.
- Ensure the piping is properly supported to prevent strain on the pump casing.
4.4 Električne veze
- Connect the pump to a three-phase 200/220V power supply, matching the frequency of 50Hz.
- All electrical work must be performed by a qualified electrician in accordance with local codes.
- Ensure correct wiring for motor rotation.
5. Uputstvo za upotrebu
5.1 Provjere prije rada
- Confirm all piping connections are secure and there are no leaks.
- Ensure the pump casing is filled with the liquid to be pumped (priming).
- Check that the power supply matches the pump's requirements.
5.2 Pokretanje pumpe
- Open the discharge valve gradually after starting the pump.
- Monitor for unusual noises or vibrations. If detected, shut down immediately and investigate.
5.3 Zaustavljanje pumpe
- Close the discharge valve gradually.
- Isključite napajanje pumpe.
5.4 Rukovanje tekućinama
This pump is designed to handle clean water within a temperature range of 0°C to 100°C. Do not use it for liquids outside this specification or for corrosive/abrasive fluids unless specifically approved by EBARA.
6. Održavanje
Regular maintenance is crucial for the longevity and optimal performance of your EBARA pump. Always disconnect power before beginning any maintenance procedures.
6.1 Redovna inspekcija
- Check for leaks around the shaft seal and piping connections.
- Listen for unusual noises or vibrations during operation.
- Monitor motor temperature.
6.2 Disassembly and Inspection (without removing piping)
A key feature of the LPD pump is the ability to disassemble and inspect internal components without detaching the pump from the main piping. Refer to the detailed exploded view diagram (not provided in this document, refer to official EBARA service manual) for specific steps. This typically involves:
- Shutting down the pump and isolating it from the power supply.
- Draining the pump casing.
- Removing the motor and impeller assembly from the casing while the casing remains inline.
- Inspecting the impeller, mechanical seal, and bearings for wear or damage.
- Replacing worn parts as necessary.
- Reassembling the pump, ensuring all seals are correctly seated.
6.3 Mechanical Seal Replacement
The pump uses a mechanical seal. If leaks persist from the shaft seal, the mechanical seal may need replacement. This is a precision component and should be handled with care. Consult a qualified technician for replacement if you are unfamiliar with the procedure.
7. Otkrivanje problema
This section provides solutions to common issues. For problems not listed here, contact EBARA technical support.
| Problem | Mogući uzrok | Rješenje |
|---|---|---|
| Pumpa se ne pokreće | Nema napajanja Preopterećenje motora Radno kolo je zaglavljeno | Provjerite priključak za napajanje i osigurač Reset overload protector Inspect impeller for obstructions |
| Low flow or no discharge | Pumpa nije punjena Suction line air leak Clogged impeller/piping | Ensure pump is fully primed Check suction connections for leaks Clean impeller and piping |
| Prekomjerna buka ili vibracije | Kavitacija Istrošeni ležajevi Neusklađenost | Check suction conditions, ensure adequate liquid supply Inspect and replace bearings Provjerite poravnanje pumpe i motora |
| Curenje zaptivke vratila | Istrošena mehanička brtva Nepravilna instalacija | Zamijenite mehaničku brtvu Reinstall mechanical seal correctly |
8. Specifikacije
| Parametar | Vrijednost |
|---|---|
| Proizvođač | EBARA Corporation |
| Naziv modela | 25LPD5.15 |
| Caliber (Nominal Diameter) | 25 mm |
| Frekvencija | 50 Hz |
| Izlaz | 0.15 kW |
| Power Voltage | Three-phase 200/220 V |
| Rukovanje tekućinom | Čista voda |
| Raspon temperature tekućine | 0°C do 100°C |
| Ukupna usisna glava | -6 m (at 20°C) |
| Impeller Type | Zatvoreno |
| Zaptivka osovine | Mehanička brtva |
| Ležaj | Sealed ball bearing (inside motor) |
| Type / Protection Method | Drip-proof protection type / IP22 (indoor) |
9. Garancija i podrška
For warranty information, technical support, or to order replacement parts, please contact your authorized EBARA distributor or visit the official EBARA website. Keep your purchase receipt and product model number (25LPD5.15) handy when contacting support.