1. Uvod

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Embraco NT6215Z1 Refrigeration Compressor. Please read this manual thoroughly before attempting any installation or operation. Keep this manual for future reference.

The Embraco NT6215Z1 is a high-temperature refrigeration compressor designed for use with R134A refrigerant. It operates on 115V power and features a 1/2 HP motor with High Starting Torque (HST).

2. Sigurnosne informacije

UPOZORENJE: Nepravilna instalacija, podešavanje, preinake, servisiranje ili održavanje mogu uzrokovati oštećenje imovine, ozljede ili smrt. Prije instaliranja ili servisiranja ove opreme temeljito pročitajte upute za instalaciju, rad i održavanje.

  • Always disconnect power before servicing the compressor.
  • Osigurajte ispravno uzemljenje kako biste spriječili strujni udar.
  • Rashladnim sredstvima rukujte pažljivo i u skladu s lokalnim propisima.
  • Nosite odgovarajuću ličnu zaštitnu opremu (LZO), uključujući zaštitne naočale i rukavice.
  • Instalaciju i servis treba da obavlja samo kvalifikovano osoblje.

3. Postavljanje i instalacija

3.1 Raspakivanje

Carefully remove the compressor from its packaging. Inspect for any shipping damage. Do not install a damaged unit.

3.2 Montaža

Mount the compressor on a stable, level surface using appropriate vibration isolation mounts. The mounting centers for this model are 8.0 inches by 4.8 inches. Ensure adequate ventilation around the compressor for proper heat dissipation.

3.3 Električni priključak

Connect the compressor to a dedicated 115V power supply circuit. Refer to the wiring diagram provided with your refrigeration system for specific connections. Ensure all electrical connections are secure and comply with local electrical codes. The compressor utilizes a Start Capacitor (G22-839) and a Relay (9660041180EM).

3.4 Refrigerant Line Connection

Connect the suction line to the 5/16 inch ODF suction connection and the discharge line to the 1/4 inch ODF discharge connection. Use proper brazing techniques and ensure all connections are leak-free. This compressor is designed for R134A refrigerant. Evacuate the system thoroughly before charging with refrigerant.

4. Uputstvo za upotrebu

4.1 Prvo pokretanje

After completing all connections and leak checks, slowly open the service valves. Apply power to the compressor. The compressor should start and begin to circulate refrigerant. Monitor system pressures and temperatures to ensure proper operation.

4.2 Normalan rad

The Embraco NT6215Z1 is a high-temperature compressor. Ensure the refrigeration system is designed for high-temperature applications. The compressor will cycle on and off as dictated by the system's thermostat or control board to maintain the desired temperature.

5. Održavanje

Regular maintenance ensures optimal performance and extends the lifespan of your compressor.

  • čistoća: Keep the compressor and surrounding area clean and free of dust and debris to ensure proper airflow and cooling.
  • Električni priključci: Povremeno provjeravajte sve električne spojeve na čvrstoću i znakove korozije.
  • Vibracija: Inspect mounting for excessive vibration. Replace worn vibration isolators if necessary.
  • Curenje rashladnog sredstva: Regularly check for refrigerant leaks using an appropriate leak detector.

Note: This product does not include additional components. Ensure all necessary system parts are sourced separately.

6. Otkrivanje problema

Before troubleshooting, always disconnect power to the unit.

ProblemMogući uzrokRješenje
Kompresor se ne pokrećeNo power; Faulty relay (9660041180EM); Faulty start capacitor (G22-839); Overload protector trippedCheck power supply; Test/replace relay; Test/replace start capacitor; Check for system overload, allow to cool and reset.
Compressor runs but does not coolLow refrigerant charge; System blockage; Faulty expansion valveCheck for leaks and recharge; Inspect and clear blockages; Inspect/replace expansion valve.
Prekomjerna buka ili vibracijeLoose mounting; Worn vibration isolators; Internal compressor issueTighten mounting bolts; Replace isolators; Consult a qualified technician for internal issues.

If problems persist, contact a qualified refrigeration technician.

7. Specifikacije

FeatureSpecifikacija
ModelNT6215Z1
Rashladno sredstvoR134A
Voltage115 Volts
konjske snage (HP)1/2 KS (0.5 KS)
Početni obrtni momentHigh Starting Torque (HST)
Usisni priključak5/16 inch ODF
Priključak za pražnjenje1/4 inch ODF
Mounting Centers8.0 inča x 4.8 inča
BtuH Capacity at 20°F Evap.3084
BtuH Capacity at 30°F Evap.4095
BtuH Capacity at 40°F Evap.5253
BtuH Capacity at 45°F Evap.5855
Start CapacitorG22-839
Relej9660041180EM
Težina artikla31 funti
Dimenzije paketa14.29 x 9.13 x 8.98 inča

8. Garancija i podrška

Specific warranty details for the Embraco NT6215Z1 compressor are not provided in this document. For warranty information or technical support, please contact Embraco directly or the authorized distributor from whom the product was purchased. Ensure you have your model number (NT6215Z1) and purchase date available when contacting support.

9. Media (Images and Videos)

No product images or official videos were provided in the source data for inclusion in this manual. For visual references, please refer to the product listing or the manufacturer's official website.

Povezani dokumenti - NT6215Z1

Preview Embraco Compressor Installation Instructions for European On-Off Compressors
Comprehensive installation instructions for Embraco European on-off compressors, covering safety, selection, installation procedures, electrical connections, troubleshooting, and handling. Essential guide for professional users, refrigeration system manufacturers, installers, and maintenance technicians.
Preview Embraco Guide to Using R600a and R290 Hydrocarbon Refrigerants
A comprehensive guide from Embraco on the safe use, handling, and servicing of R600a and R290 hydrocarbon refrigerants, covering system design, safety standards, general information, component specifications, and compressor replacement procedures.
Preview Katalog kompresora Embraco Nidec za azijsko-pacifičku regiju | Rješenja za hlađenje
Istražite sveobuhvatni katalog kompresora Embraco Nidec za azijsko-pacifičku regiju, koji sadrži kompresore s fiksnom i promjenjivom brzinom, tehničke specifikacije i vodiče za primjenu rashladnih sistema.
Preview Embraco Compressor Replacement Guide: Cross Reference for Secop & Danfoss
Find the perfect Embraco compressor replacement for your Secop and Danfoss units. This guide provides a comprehensive cross-reference with detailed specifications, performance data, and dimensions for various refrigerants like R-134A, R290, and R-404A.
Preview Manual del Inversor Electrónico Embraco CF10B para Compresores de Velocidad Variable
Guía completa del manual del inversor electrónico Embraco CF10B, cubriendo especificaciones técnicas, instalación, funcionamiento y diagnóstico para compresores de velocidad variable.
Preview Embraco NJ 9232GS Compressor Technical Data
Detailed technical specifications and performance data for the Embraco NJ 9232GS hermetic reciprocating compressor, covering application limits, mechanical and electrical data, and performance curves for commercial refrigeration systems.