1. Uvod
The OPUS BT-C3100 V2.2 is an advanced universal battery charger designed for a wide range of rechargeable batteries. It features four independent charging slots, an intuitive LCD display, and multiple operating modes to efficiently charge, discharge, test, and refresh your batteries. This manual provides detailed instructions for safe and effective use of your charger.
2. Važne informacije o sigurnosti
Uvijek pročitajte i razumite sva sigurnosna upozorenja i upute prije upotrebe ovog proizvoda. Nepoštivanje ovih uputa može dovesti do strujnog udara, požara ili ozbiljnih ozljeda.
- Use only the provided AC/DC adapter.
- This charger is designed for indoor use only.
- Ensure proper battery polarity when inserting batteries.
- Ne pokušavajte da punite nepunjive baterije.
- Keep the charger and batteries away from water, moisture, and high temperatures.
- The charger includes overheat detection to protect both the batteries and the unit itself from excessive heat. If overheating occurs, the charging current will be reduced to 0mA until the temperature drops below 40 degrees Celsius.
- Nemojte rastavljati niti modificirati punjač.
3. Proizvod je gotovview
The OPUS BT-C3100 V2.2 features a robust design with four independent battery slots, each capable of displaying real-time charging information on the integrated LCD. A cooling fan is incorporated to manage internal temperatures during operation.

Slika 3.1: Prednja strana view of the OPUS BT-C3100 V2.2 charger with LCD display.
3.1 Ključne karakteristike
- Four independent charging slots for simultaneous operation.
- LCD display with backlight showing battery voltage, charge/discharge current, charging time, and battery capacity.
- Selectable charging currents: 200mA, 300mA, 500mA, 700mA, 1000mA, 1500mA, 2000mA. (Note: 1500mA and 2000mA are only available when using slot 1 or 4).
- Selectable discharge currents: 200mA, 300mA, 500mA, 700mA, 1000mA (for Li-ion cells only). Default discharge current is 500mA.
- Integrated minus delta voltage (-ΔV) termination for NiCd/NiMh batteries.
- Constant current (CC) and constant voltage (CV) charging for Li-ion batteries.
- Overheat, short-circuit, over-charging, and over-discharging protection.
- New fan cover for improved cooling.

Figure 3.2: Visual representation of the charger's main features.
4. Tehničke specifikacije
| Feature | Specifikacija |
|---|---|
| Ulazni voltage | AC 100 ~ 240V 50 / 60HZ |
| Output Voltage | DC 12V, 3.0A |
| Opseg struje punjenja | 200, 300, 500, 700, 1000, 1500, 2000mA |
| Raspon struje pražnjenja | 200, 300, 500, 700, 1000mA (Li-ion only) |
| Max. Charging Capacity | Up to 20000mAh |
| Radna temperatura | 0 - 40 °C (32 - 104 °F) |
| Voltage Devijacija | Max 0.03V @ 4.2V |
| Current Deviation | Max 5% |
| Dimenzije proizvoda (D x Š x V) | 14.4 x 9.8 x 3.9 cm (5.67 x 3.86 x 1.54 inča) |
| Težina artikla | 8.3 unci (0.52 lbs) |
5. Postavljanje i početna upotreba
5.1 Spajanje adaptera za napajanje
Connect the provided DC 12V, 3.0A power adapter to the charger's input port located on the back. Plug the adapter into a standard AC 100-240V, 50/60Hz wall outlet. The LCD display will illuminate, indicating the charger is ready for use.

Slika 5.1: Pozadi view of the charger with power input and cooling fan.
5.2 Umetanje baterija
The charger features a classical slider construction to accommodate various battery sizes. Gently insert batteries into the charging slots, ensuring the positive (+) and negative (-) terminals align correctly with the markings in the slots. The charger will automatically detect the battery type (Ni-MH, Ni-Cd, or Li-ion) and display its current voltage.

Figure 5.2: Proper insertion of a battery into a charging slot.
6. Načini rada
The BT-C3100 V2.2 offers four distinct operating modes, selectable via the 'MODE' button. Each mode serves a specific purpose for battery management.

Figure 6.1: LCD display showing available operating modes.
6.1 Odabir načina rada
After inserting batteries, press the 'MODE' button to cycle through the available modes. Use the 'CURRENT' button to adjust the current for the selected mode, and the 'SLOT' button to select individual slots for specific settings.
- NAKNADA: Charges the battery to its maximum capacity. The LCD displays voltage, current, and accumulated capacity.
- ISPRAVA: Discharges the battery to a safe low voltage. Useful for cycling NiCd/NiMh batteries to reduce memory effect.
- TEST: Measures the actual capacity of the battery. The charger will fully charge the battery, then discharge it while measuring the discharged capacity, and finally recharge it. The discharged capacity is displayed.
- QUICK TEST: Measures the internal resistance of the battery. This mode quickly determines the battery's health.
- OSVJEŽITI: Cycles the battery through charge and discharge multiple times to restore its full capacity, especially for older NiCd/NiMh batteries.
7. Kompatibilnost baterija
The OPUS BT-C3100 V2.2 is compatible with a wide range of rechargeable battery chemistries and sizes.
7.1 Supported Battery Types and Voltages
The charger supports Ni-MH, Ni-Cd, and various Li-ion battery types. For specific Li-ion chemistries (Li-FeO4, high voltage Li-ion), a switch on the board allows selection of different charging termination voltages (3.7V, 4.2V, 4.35V).

Figure 7.1: Supported battery types and their corresponding voltages.
7.2 Supported Battery Sizes
The charger is designed for common battery sizes, including AA (LR6) and AAA (LR3) for NiCd/NiMh, and various 3.7V Li-ion sizes such as 10440, 14500, 16340, 17335, 17500, 18490, 17670, 18650, 26650.

Figure 7.2: The charger accommodates a wide range of battery sizes.
8. Smjernice za punjenje
8.1 Trenutni odabir
The charger allows manual selection of charging and discharging currents. For optimal battery life and safety, it is generally recommended to use lower currents for smaller batteries and higher currents for larger capacity batteries. Note that 1500mA and 2000mA charging currents are only available when using a single battery in slot 1 or slot 4.
8.2 Upravljanje toplinom
During charging and discharging, especially at higher currents, batteries and the charger may generate heat. The BT-C3100 V2.2 is equipped with a cooling fan that activates when the internal temperature or battery temperature exceeds 40°C (104°F). If the battery temperature is sensed to be over 60°C (140°F), the over-heat protection will activate, halting the current working mode for all 4 slots by reducing the charging current to 0mA. Operation will resume once the battery temperature drops below 40°C. Ensure adequate ventilation around the charger during operation.
9. Održavanje
- čišćenje: Disconnect the charger from power before cleaning. Use a soft, dry cloth to wipe the exterior. Do not use abrasive cleaners or solvents.
- Skladištenje: Čuvajte punjač na hladnom i suvom mestu dalje od direktne sunčeve svetlosti i ekstremnih temperatura.
- Održavanje baterije: Always remove batteries from the charger once the process is complete.
10. Otkrivanje problema
- Punjač se ne uključuje: Ensure the power adapter is securely connected to both the charger and the wall outlet. Verify the outlet has power.
- Baterija nije detektovana: Check that the battery is inserted correctly with proper polarity. Ensure the battery is a supported rechargeable type.
- Problemi sa pregrijavanjem: If the charger or batteries become excessively hot, ensure the cooling fan is not obstructed. Reduce the charging current if possible. The charger will automatically halt operation if temperatures exceed safe limits.
- Low Voltage Battery Recovery: The charger is capable of recovering some deeply discharged batteries. If a battery is too low, the charger may initiate a trickle charge to bring its voltage up before regular charging begins.
- Inaccurate Capacity Readings: Ensure the 'TEST' or 'REFRESH' mode is used for accurate capacity measurement. Allow the full cycle to complete.