1. Uvod
This manual provides essential instructions for the safe and efficient installation, operation, and maintenance of your Duluth Forge DLS-24R-1 Dual Fuel Ventless Fireplace Logs Set. This unit is designed to operate on either natural gas or liquid propane, offering a versatile heating solution for your indoor space. Please read this manual thoroughly before installation or use and retain it for future reference.
2. Važne informacije o sigurnosti
UPOZORENJE: Nepravilna instalacija, podešavanje, izmjena, servisiranje ili održavanje mogu uzrokovati ozljede ili materijalnu štetu. Pogledajte ovaj priručnik. Za pomoć ili dodatne informacije obratite se kvalificiranom instalateru, servisnoj agenciji ili dobavljaču plina.
- Prijedlog 65 Upozorenje: Ovaj proizvod vas može izložiti hemikalijama, uključujući ugljen monoksid, za koji je u državi Kalifornija poznato da uzrokuje urođene mane ili druge reproduktivne štete. Za više informacija idite na www.P65Warnings.ca.gov.
- This ventless gas log set is 99.9% efficient and does not require an outside duct or chimney.
- Equipped with a Safety Pilot O.D.S. (Oxygen Depletion Sensor) that automatically shuts down the unit if carbon monoxide or lack of oxygen is detected.
- Features Battery-Assisted Piezo ignition for reliable startup.
- Mora se ugraditi u zidanu ili ložište odobreno od strane agencije.
- Minimum Firebox Size Required: 20 inches (H) x 28 inches (W) in front (23 inches W at rear) x 15 inches (D).
- Designed for Indoor Use Only.
- Ensure adequate ventilation in the room where the unit is installed.
3. Postavljanje i instalacija
Professional installation by a qualified technician is highly recommended for gas connections to ensure safety and compliance with local codes.
3.1 Raspakivanje i pregled
- Pažljivo izvadite sve komponente iz pakovanja.
- Inspect all items for any damage. Contact your retailer immediately if any damage is found.
- Ensure all listed components are present: 8 Hand Painted Ceramic Logs, Bag of Embers, Remote Control, Receiver Box, AA & AAA Batteries, Hardware Pack, Damper Clamp.
3.2 Instalacija baterije
- For the Ignition: Install 1 AAA battery into the designated ignition compartment on the main unit.
- Za daljinski upravljač: Install 2 AAA batteries into the remote control unit.
- For the Receiver Box: Install 4 AA batteries into the receiver box.
3.3 Povezivanje prijemnika
Connect the main unit with the receiver, ensuring that the receiver is in the OFF position before connecting. Refer to the included wiring diagram for proper connection.
3.4 Postavljanje trupaca
The log set includes 8 hand-painted ceramic logs designed for a realistic appearance. Arrange the logs according to the diagram provided in the detailed instruction sheet included with your product. Proper log placement is crucial for optimal flame pattern and safe operation.

Slika: prample of log arrangement for a natural appearance.
3.5 Ember Material Placement
Distribute the included bag of glowing ember material over the burner pan to enhance the realistic fire effect. Do not obstruct the burner ports.

Image: The Duluth Forge DLS-24R-1 log set with flames and glowing embers.
4. Uputstvo za upotrebu
4.1 Lighting the Pilot Flame
- Provjerite da li je dovod plina otvoren.
- Press lightly on the control knob and turn it counter-clockwise to the PILOT pozicija.
- While holding the control knob in, press and hold the IGNITION dugme dok se pilot plamen ne upali.
- Continue to hold the control knob in for approximately 30-60 seconds after the pilot lights to allow the thermocouple to heat up and stabilize the pilot flame. Release the knob slowly. If the pilot goes out, repeat the process.
4.2 Igniting the Main Burner (Remote Control)
Your log set includes a remote control for convenient operation.

Image: Remote control unit with display and buttons.
- Ensure the pilot flame is lit and stable.
- Set the receiver box to the REMOTE pozicija.
- Press any button on the remote control to activate its display.
- Once the display is active, press the ON dugme na daljinskom upravljaču da biste upalili glavni plamen.
4.3 Adjusting Temperature and Mode
- Koristite MODE button on the remote control to switch between manual mode and automatic constant temperature (thermostat) mode.
- In thermostat mode, use the up and down arrow buttons to set your desired room temperature. The unit will automatically adjust the flame to maintain this temperature.
4.4 Turning Off the Unit
- To turn off the main flame, press the OFF dugme na daljinskom upravljaču.
- To turn off the pilot flame, rotate the control knob on the main unit clockwise to the OFF position. Always turn off the pilot flame when the unit will not be used for an extended period.
5. Održavanje
Regular maintenance ensures the longevity and safe operation of your fireplace logs.
- Zapisi čišćenja: Periodically inspect the ceramic logs for soot buildup. Clean gently with a soft brush or cloth. Do not use abrasive cleaners.
- Čišćenje plamenika: Keep the burner ports free of dust and debris. Use a vacuum cleaner with a brush attachment to gently clean the burner area.
- Pilot Assembly: Ensure the pilot assembly and ODS sensor are clean and free from obstructions.
- Opšta njega: Keep the area around the fireplace clear of combustible materials.
Always ensure the unit is completely cool and the gas supply is turned off before performing any maintenance.
6. Otkrivanje problema
If you encounter issues, refer to the following common problems and solutions. For persistent problems, contact a qualified service technician.
| Problem | Mogući uzrok | Rješenje |
|---|---|---|
| Pilot will not light or stay lit. | No gas supply, air in gas line, thermocouple not heating, ODS sensor dirty. | Check gas supply. Bleed air from line. Hold pilot knob longer. Clean ODS sensor. |
| Glavni plamenik se ne pali. | Pilot not lit, receiver in OFF position, remote batteries low, gas valve closed. | Ensure pilot is lit. Set receiver to REMOTE. Replace remote batteries. Check gas valve. |
| Daljinski upravljač ne reaguje. | Low batteries, receiver out of range, receiver in OFF position. | Replace remote/receiver batteries. Move closer to unit. Set receiver to REMOTE. |
| Neobični mirisi tokom rada. | Initial burn-off of manufacturing oils/paint, inadequate ventilation. | Ensure proper ventilation. Odor should dissipate after initial use. If persistent, consult technician. |
7. Specifikacije
| Feature | Detalj |
|---|---|
| Broj modela | DLS-24R-1 |
| Brand | Duluth Forge |
| Izlaz toplote | 33,000 BTU |
| Pokrivenost grijanja | Do 1,300 sq. ft. |
| Vrsta goriva | Dvogorivni (prirodni plin ili tekući propan) |
| Materijal | Ceramic, Oak |
| Dimenzije proizvoda (D x Š x V) | 15" x 20" x 28" |
| Težina artikla | 30 funti |
| Tip ventilacije | Vent Free |
| Posebna karakteristika | Daljinski upravljač |
| Uključene komponente | 8 Hand Painted Ceramic Logs, Bag of Embers, Remote Control, Receiver Box, AA & AAA Batteries, Hardware Pack, Damper Clamp |

Image: Product dimensions and minimum firebox requirements.
8. Garancija
This Duluth Forge product comes with a Ograničena garancija. For specific details regarding coverage, duration, and terms, please refer to the warranty information included in your product packaging or contact Duluth Forge customer support directly. Keep your proof of purchase for warranty claims.
9. Korisnička podrška
For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact Duluth Forge customer support. Refer to your product packaging or the official Duluth Forge webstranicu za najnovije kontakt informacije.