1. Uvod
The GVS Elipse P100 Dust Half Mask Respirator is designed to provide personal respiratory protection against dust and fumes. Its compact and lightweight design ensures comfort and a full range of vision, making it suitable for various industrial and safety applications. This manual provides essential information for the proper use, maintenance, and care of your respirator.

Slika 1: Prednja strana view of the GVS Elipse P100 Respirator.
Video 1: Krajview of Elipse respirators by GVS, highlighting key features and benefits.
2. Postavljanje i montaža
Proper fitting is crucial for effective respiratory protection. Follow these steps to correctly set up and wear your GVS Elipse P100 Respirator:
- Pregledajte respirator: Before each use, check the mask body, straps, and filters for any signs of damage, cracks, or wear. Ensure the filters are securely attached.
- Podesite trake za glavu: Hold the respirator with one hand and pull the head straps over your head with the other. Position the mask over your nose and mouth. The top strap should rest on the crown of your head, and the neck strap should rest around your neck below your ears.
- Tighten Straps: Pull the ends of the straps to tighten the mask until it feels secure but comfortable. Do not overtighten. The mask should fit snugly against your face without gaps.
- Perform a Seal Check:
- Provjera pozitivnog pritiska: Place the palm of your hand over the exhalation valve cover (front center of the mask) and gently exhale. The mask should slightly bulge outwards, and you should feel no air leaking from the edges.
- Provjera negativnog pritiska: Place the palms of your hands over the filter covers on both sides of the mask and gently inhale. The mask should pull inward towards your face, and you should feel no air leaking from the edges.

Slika 2: Natrag view of the respirator showing adjustable straps.
Video 2: An unboxing and fitting demonstration of the GVS Elipse P100 Respirator.
3. Uputstvo za upotrebu
Once properly fitted, the GVS Elipse P100 Respirator provides effective protection in environments containing dust and fumes. It is recommended for use in situations involving micro-organisms, marble, gypsum, titanium oxide, rock wool, wood, detergents, and various dusts that can cause lung disease, including asbestos, bauxite, coal, silica, and iron.
The mask's compact design allows for a full range of vision and does not interfere with other personal protective equipment (PPE) such as eye or ear protection. Its low breathing resistance minimizes user fatigue during extended periods of use.

Figure 3: Worker using the respirator during drilling, demonstrating compatibility with safety glasses.
Video 3: Demonstrates the comfort and lightweight nature of the mask during use.
Video 4: Emphasizes the importance of wearing a respirator for protection in dusty environments.
4. Održavanje
Regular maintenance ensures the longevity and effectiveness of your respirator. Filters should be replaced when breathing resistance becomes noticeably high or when odors are detected.
4.1 Zamjena filtera
- Remove Used Filters: Gently twist and pull the filter covers to detach them from the mask body. Remove the old filter cartridges.
- Umetni nove filtere: Align the new filter cartridges with the openings on the mask body and push them firmly into place until they click. Ensure a secure fit.
- Reattach Covers: Place the filter covers back over the new filters and twist to lock them into position.
Video 5: Detailed instructions on how to remove and replace the Elipse P100 filters.
4.2 Čišćenje i skladištenje
- čišćenje: After each use, wipe the mask body (excluding filters) with a damp cloth using mild soap and water. Do not submerge the entire mask or filters in water. Allow all parts to air dry completely before reassembly or storage.
- Skladištenje: Store the respirator in a clean, dry place away from direct sunlight, extreme temperatures, and contaminants. It is recommended to store it in a sealed bag or container to protect the filters from dust and moisture when not in use.
5. Otkrivanje problema
If you encounter issues with your GVS Elipse P100 Respirator, consider the following:
- Otežano disanje: This usually indicates that the filters are clogged and need to be replaced. Ensure the exhalation valve is not obstructed.
- Smelling Contaminants: If you can smell or taste contaminants while wearing the mask, the seal may be compromised, or the filters may be exhausted. Re-perform a seal check and replace filters if necessary.
- Discomfort or Skin Irritation: Ensure the straps are not overtightened. The mask is made from hypoallergenic thermoplastic elastomer (TPE) to minimize irritation, but prolonged use or improper fit can still cause discomfort. Adjust the fit or take breaks as needed.
- Fogging of Eyewear: Ensure the mask is properly sealed around the nose bridge. A good seal prevents exhaled air from escaping upwards and fogging glasses.
6. Specifikacije
| Feature | Detalj |
|---|---|
| Broj modela | SPR451 |
| Odobrenje | NIOSH Approval number: P100 TC-84A-6949 (Meets 42CFR84 requirements) |
| Materijal | Thermoplastic Elastomers (TPE) |
| Boja | Plava |
| Veličina | Small/Medium (Elipse comes in 2 sizes) |
| Dimenzije proizvoda | 5 x 4 x 4 inča |
| Težina | 6.4 unce |
| Zemlja porijekla | Ujedinjeno Kraljevstvo |
7. Garancija i podrška
For detailed warranty information and support, please refer to the official GVS user manual available in PDF format. Please note that no returns are allowed on this product.
Zvanični korisnički priručnik (PDF): Preuzmite ovdje