U.S. Solid USS-LNS00001

U.S. Solid 500ml Liquid Nitrogen Sprayer (Model USS-LNS00001) Instruction Manual

Brand: U.S. Solid | Model: USS-LNS00001

1. Uvod

This manual provides essential instructions for the safe and effective operation, maintenance, and troubleshooting of your U.S. Solid 500ml Liquid Nitrogen (LN2) Sprayer. Please read this manual thoroughly before using the device to ensure proper handling and to prevent injury or damage.

The U.S. Solid Liquid Nitrogen Sprayer is designed for controlled application of liquid nitrogen in various settings. It features a lightweight aluminum alloy canister and comes with 9 specialized freeze heads for diverse applications.

2. Sigurnosne informacije

WARNING: Liquid Nitrogen (LN2) is extremely cold (-196°C / -320°F) and can cause severe frostbite or cryogenic burns upon contact with skin or eyes. Always handle LN2 with extreme caution and wear appropriate personal protective equipment (PPE).

  • Always wear cryogenic protective gloves, a face shield or safety glasses, and long-sleeved clothing when handling liquid nitrogen or operating the sprayer.
  • Use in a well-ventilated area to prevent oxygen displacement, which can lead to asphyxiation. LN2 rapidly vaporizes into gaseous nitrogen, which is an inert gas.
  • Do not store liquid nitrogen in sealed containers, as pressure buildup can cause an explosion. This sprayer is not designed for prolonged storage of LN2.
  • Avoid direct contact of LN2 with skin, eyes, or clothing. If contact occurs, immediately flush the affected area with lukewarm water and seek medical attention.
  • Keep the sprayer upright during transport and operation to prevent spills.
  • Ensure the sprayer is empty and depressurized before attempting any maintenance or cleaning.
  • This product does not come with liquid nitrogen. LN2 must be purchased separately from a qualified supplier.

3. Sadržaj paketa

Prilikom raspakivanja provjerite da li su svi artikli prisutni i neoštećeni:

  • U.S. Solid 500ml Liquid Nitrogen Sprayer Unit
  • 9 Freeze Heads (8 without holes, 1 with a hole)
  • Storage Case (if included with your purchase)
  • Uputstvo za upotrebu (ovaj dokument)
U.S. Solid 500ml Liquid Nitrogen Sprayer with 9 freeze heads

Image 1: The U.S. Solid 500ml Liquid Nitrogen Sprayer with its included 9 freeze heads. The sprayer is a stainless steel cylinder with a handle and a long, curved nozzle. The freeze heads are small, metallic attachments.

4. Components Overview

Familiarize yourself with the main parts of the sprayer:

  • Main Vessel: The insulated container for liquid nitrogen.
  • Lid/Cap: Seals the vessel and contains the internal mechanism for dispensing.
  • Sklop mlaznice: The long, curved tube through which LN2 is dispensed.
  • Flow Control Switch: A small knob on the lid that regulates LN2 flow when rotated.
  • ručka: For carrying and holding the sprayer during use.
  • Freeze Heads: Various attachments for precise application.
Close-up of the top of the U.S. Solid Liquid Nitrogen Sprayer

Slika 2: Krupni plan view of the top section of the sprayer, showing the black lid, the curved nozzle, and the small flow control switch.

Assortment of 9 freeze heads for the LN2 sprayer

Image 3: The nine distinct metallic freeze heads, varying in shape and size, designed for different application patterns.

5. Podešavanje

  1. Pripremite prostor: Ensure you are in a well-ventilated space. Have all necessary PPE (cryogenic gloves, face shield/safety glasses, long sleeves) readily available and worn.
  2. Inspect the Sprayer: Before each use, visually inspect the sprayer for any signs of damage, cracks, or loose components. Ensure the lid screws on securely.
  3. Fill with Liquid Nitrogen:
    • Carefully unscrew the lid from the main vessel.
    • Using a suitable LN2 transfer device (e.g., a funnel designed for cryogenic liquids), slowly pour liquid nitrogen into the sprayer vessel. Do not overfill. The maximum capacity is 500ml.
    • Once filled, carefully screw the lid back onto the vessel, ensuring it is tight but do not overtighten or hold the steel pipe to rotate the lid.
  4. Attach Freeze Head: Select the appropriate freeze head for your application. Screw it onto the end of the nozzle assembly until secure.

6. Uputstvo za upotrebu

Always wear appropriate PPE during operation.

  1. Pozicioniranje: Hold the sprayer by its handle, keeping it upright. Point the nozzle away from yourself and others.
  2. Pokreni tok: The sprayer does not have a trigger button. To begin dispensing LN2, slowly rotate the flow control switch on the lid. Rotating it clockwise typically increases the flow, and counter-clockwise decreases it.
  3. primjena: Direct the stream of liquid nitrogen or the contact tip of the freeze head to the target area. Maintain a safe distance if spraying directly.
  4. Stop Flow: To stop dispensing, rotate the flow control switch back to its closed position.
  5. Nakon upotrebe: After use, allow any remaining LN2 to evaporate in a well-ventilated area. Do not store the sprayer with LN2 for extended periods (storage time is typically 12-20 hours depending on ambient temperature).

7. Održavanje

Proper maintenance ensures the longevity and safe operation of your sprayer.

  • čišćenje: After all liquid nitrogen has evaporated, the sprayer can be wiped clean with a damp cloth. Ensure all components are dry before reassembly or storage. Do not immerse the entire unit in water.
  • inspekcija: Regularly inspect the lid, nozzle, and freeze heads for any blockages, wear, or damage. Replace any damaged parts immediately.
  • Skladištenje: Store the empty and clean sprayer in its protective case (if applicable) in a dry, cool place, away from direct sunlight and extreme temperatures.
U.S. Solid Liquid Nitrogen Sprayer stored in its protective case

Image 4: The liquid nitrogen sprayer neatly placed within its custom-fitted protective carrying case, which features foam padding for secure storage.

8. Otkrivanje problema

ProblemMogući uzrokRješenje
No LN2 flow or very weak flow
  • Flow control switch is closed.
  • Sprayer is empty or nearly empty.
  • Nozzle or freeze head is clogged.
  • Rotate the flow control switch to open.
  • Refill the sprayer with LN2.
  • Remove and clean the nozzle/freeze head.
LN2 leaks from the lid area
  • Poklopac nije čvrsto zatvoren.
  • Oštećen poklopac ili zaptivka.
  • Provjerite je li poklopac sigurno zatvoren.
  • Inspect the lid and seal for damage; replace if necessary.
Sprayer does not hold LN2 for expected duration
  • Not designed for long-term storage.
  • Temperatura okoline je visoka.
  • Poklopac nije pravilno zatvoren.
  • This unit is for application, not storage (0.5 to 1 day holding time).
  • Use in a cooler environment if possible.
  • Ensure lid is tightly sealed.

9. Specifikacije

FeatureDetalj
BrandUS Solid
Broj modelaUSS-LNS00001
Kapacitet0.5 Liters (500ml / 16 oz.)
Prečnik posude3.15 inča (80 mm)
Vessel Height8.27 inča (210 mm)
Prazna težina0.57 kg (približno 1.5 lbs)
Freeze Heads Included9 (8 without hole, 1 with hole)
MaterijalAluminum Alloy (interior canister)
Static Holding TimeNot designed for prolonged storage (0.5 to 1 day, or 12-20 hours depending on ambient temperature)

10. Garancija i podrška

For warranty information, technical support, or to inquire about replacement parts, please contact U.S. Solid customer service. Refer to the product packaging or the official U.S. Solid webstranicu za najnovije kontakt podatke.

Proizvođač: US Solid

Webstranica: www.ussolid.com

Email: service@ussolid.com

Povezani dokumenti - USS-LNS00001

Preview U.S. Solid Motorized Ball Valve Installation and Maintenance Manual
Comprehensive guide for U.S. Solid Motorized Ball Valves, covering installation, wiring schematics, DC/AC operation, manual override, FAQs, environmental protection, warranty, and detailed specifications for models USS-MSV00201-216.
Preview U.S. Solid Ultrasonic Cleaner Dual Frequency - Model USS-FX30-FX35 User Manual
Comprehensive user manual for the U.S. Solid Dual Frequency Ultrasonic Cleaner (models USS-FX30, USS-FX31, USS-FX32, USS-FX33, USS-FX34, USS-FX35). Learn about operating principles, safety instructions, applications, specifications, and operation.
Preview U.S. Solid Electric Ball Valve (Two-Way) - USS-EBV Models Instruction Manual
Instruction manual for U.S. Solid USS-EBV series electric ball valves, covering product features, specifications, wiring diagrams, manual operation, and frequently asked questions.
Preview Uputstvo za upotrebu analitičke vage US Solid USS-DBS
Comprehensive operating manual for the U.S. Solid USS-DBS series analytical balances, covering features, specifications, installation, usage, calibration, maintenance, troubleshooting, and RS232 interface.
Preview U.S. Solid USS-DBS Digital Balance Operating Manual
Comprehensive operating manual for U.S. Solid USS-DBS series digital balances, covering specifications, installation, usage, maintenance, and troubleshooting. Learn how to calibrate, tare, and use piece counting functions.
Preview U.S. Solid USS-DBS82 Precision Balance Instruction Manual
Comprehensive instruction manual for the U.S. Solid USS-DBS82 Series Precision Balance, covering safety precautions, design, operation, technical specifications, and contact information.