Greisinger GPHU 014 MP/BNC pH konverter - uputstvo za upotrebu

Model: GPHU 014 MP/BNC

1. Uvod

This manual provides comprehensive instructions for the safe and efficient operation of your Greisinger GPHU 014 MP/BNC pH Measurement Converter. Please read this manual thoroughly before using the device to ensure proper functionality and to prevent damage. Keep this manual for future reference.

The GPHU 014 MP/BNC is designed to convert pH electrode signals into a standardized output, allowing for precise pH monitoring in various applications. It is intended for use with compatible pH electrodes featuring a BNC connector.

2. Sigurnosne informacije

  • Always operate the device within its specified environmental conditions.
  • Ne izlažite uređaj ekstremnim temperaturama, direktnoj sunčevoj svjetlosti ili visokoj vlažnosti.
  • Izbjegavajte ispuštanje ili izlaganje uređaja jakim udarima.
  • Ensure proper electrical connections are made according to the instructions to prevent electrical shock or damage.
  • Ne pokušavajte sami otvarati ili popravljati uređaj. Za sve servisne radove obratite se kvalifikovanom osoblju.
  • Use only compatible pH electrodes and accessories with this converter.
  • Dispose of the device and any associated components in accordance with local environmental regulations.

3. Sadržaj paketa

Molimo Vas da provjerite sadržaj paketa prilikom prijema. Ukoliko bilo koji artikl nedostaje ili je oštećen, odmah se obratite svom dobavljaču.

  • Greisinger GPHU 014 MP/BNC pH Measurement Converter
  • Uputstvo za upotrebu (ovaj dokument)
  • Mounting accessories (if applicable, check packaging)

Note: A pH electrode is not included with this converter and must be purchased separately.

4. Proizvod je gotovview

The Greisinger GPHU 014 MP/BNC is a compact and robust pH measurement converter designed for industrial and laboratory applications. It features a clear digital display and intuitive controls for easy operation.

Greisinger GPHU 014 MP/BNC pH Measurement Converter front view

Slika 1: Front view of the Greisinger GPHU 014 MP/BNC pH Measurement Converter. The display shows "7.46 pH" and includes "ATC" and "Temp" indicators. Below the display are three buttons labeled "SET 1", "▼ 2", and "▲ 3". A BNC connector is visible on the right side for electrode connection. Two small ports are visible at the bottom.

Greisinger GPHU 014 MP/BNC pH Measurement Converter side view

Slika 2: Side view of the Greisinger GPHU 014 MP/BNC pH Measurement Converter, highlighting the BNC connector and the robust housing. The connector is labeled "AMPHENOL".

Ključne komponente:

  • Digitalni prikaz: Shows pH value, temperature, and status indicators.
  • SET Button (1): Koristi se za unos i potvrdu postavki.
  • Dugme za donji pritisak (2): Used to navigate menus and decrease values.
  • Dugme za gore (3): Used to navigate menus and increase values.
  • BNC konektor: For connecting a compatible pH electrode.
  • Ulazna snaga: (Location not visible in images, refer to device for exact position)

5. Podešavanje

5.1. Montaža

The converter can be mounted using the integrated mounting points (screws visible in Figure 1). Ensure the mounting location is stable, free from excessive vibration, and within the specified operating temperature range.

5.2. Connecting the pH Electrode

  1. Ensure the converter is powered off.
  2. Carefully connect your pH electrode's BNC connector to the BNC input on the right side of the GPHU 014 MP/BNC converter (refer to Figure 1 and 2).
  3. Ensure the connection is secure but do not overtighten.

5.3. Priključak za napajanje

Connect the appropriate power supply to the converter. Refer to the device labeling for specific voltage and current requirements. Ensure the power source is stable and matches the device's specifications.

5.4. Inicijalna kalibracija

Before first use, or after prolonged storage, the pH converter and electrode system must be calibrated. Refer to your pH electrode's manual for specific calibration buffer requirements.

  1. Uključite uređaj.
  2. Access the calibration menu using the SET button. (Specific steps may vary, consult the device's on-screen prompts or a more detailed technical manual if available).
  3. Follow the on-screen instructions to perform a 2-point or 3-point calibration using standard pH buffer solutions (e.g., pH 4.01, 7.00, 10.01).
  4. Rinse the electrode thoroughly with distilled water between buffer solutions.
  5. Confirm calibration settings.

6. Operativni

6.1. Mjerenje

  1. Ensure the pH electrode is properly connected and calibrated.
  2. Immerse the pH electrode into the sample solution, ensuring the sensing bulb and reference junction are fully submerged.
  3. Allow sufficient time for the reading to stabilize on the digital display. The display will show the current pH value.
  4. Note any temperature readings if the electrode has an integrated temperature sensor and ATC (Automatic Temperature Compensation) is active.

6.2. Navigacija menijem

The SET, ▼, and ▲ buttons are used to navigate through the device's menu options. Press SET to enter the menu or confirm a selection. Use ▼ and ▲ to scroll through options or adjust values.

  • SET (1): Enter/Exit menu, confirm selection.
  • ▼ (2): Scroll down, decrease value.
  • ▲ (3): Scroll up, increase value.

Specific menu functions (e.g., setting alarm limits, output configuration) will be detailed in a more advanced technical manual or on-screen prompts.

7. Održavanje

7.1. Cleaning the Converter

Wipe the exterior of the converter with a soft, damp krpu. Ne koristite abrazivna sredstva za čišćenje ili rastvarače. Pazite da tekućina ne uđe u uređaj.

7.2. Održavanje pH elektroda

Proper maintenance of the pH electrode is crucial for accurate readings and extended lifespan. Refer to your specific pH electrode's instruction manual for detailed care instructions. General guidelines include:

  • Always keep the electrode's sensing bulb hydrated, typically in a storage solution or pH 7 buffer. Never store dry.
  • Rinse the electrode with distilled or deionized water after each measurement.
  • Clean the electrode regularly to remove sample residues. Specific cleaning solutions may be required depending on the application.
  • Recalibrate the electrode regularly, especially if readings become unstable or inaccurate.

7.3. Skladištenje

When not in use for extended periods, store the converter in a clean, dry environment at room temperature. Ensure the pH electrode is properly stored according to its manufacturer's recommendations.

8. Otkrivanje problema

Problem Mogući uzrok Rješenje
Nema prikaza/Uređaj se ne uključuje No power, faulty power supply, incorrect connection. Check power cable and source. Ensure correct voltage.
Unstable or inaccurate pH readings Electrode not calibrated, dirty electrode, damaged electrode, air bubbles, incorrect temperature compensation. Recalibrate electrode. Clean electrode. Replace electrode if damaged. Ensure electrode is fully submerged. Check ATC settings.
Poruka "Greška" na ekranu Electrode fault, out of range measurement, internal device error. Check electrode connection. Try another electrode if available. Refer to specific error codes in a detailed technical manual. Contact support if persistent.
Sporo vreme odziva Aged or dirty electrode, low sample temperature. Clean or recondition electrode. Allow electrode to equilibrate with sample temperature. Consider replacing electrode.

If the problem persists after attempting these solutions, please contact Greisinger customer support or your local distributor.

9. Specifikacije

Feature Detalj
Proizvođač GREISINGER
Broj modela stavke 602331
Dimenzije proizvoda (D x Š x V) 5.5 x 8.2 x 8 cm; 9.07 grama
ASIN B00ICKLET6
Količina artikala 1
Battery(ies) included br
Battery(ies) required br
Datum prve dostupnosti na Amazon.com.be 12. avgust 2022
Discontinued by manufacturer br
Dostupnost rezervnih dijelova Informacije o rezervnim dijelovima nisu dostupne

10. Garancija i podrška

Greisinger products are manufactured to high-quality standards. For information regarding warranty terms and conditions, please refer to the warranty card included with your product or visit the official Greisinger website.

For technical support, troubleshooting assistance beyond this manual, or to inquire about spare parts and service, please contact your authorized Greisinger dealer or the manufacturer directly. Contact information can typically be found on the product packaging or the official Greisinger website.

Povezani dokumenti - GPHU 014 MP/BNC

Preview GREISINGER GE xxx Uputstvo za upotrebu: pH elektrode
Sveobuhvatno uputstvo za upotrebu GREISINGER GE xxx serije pH elektroda, koje obuhvata sigurnost, osnove, mjerenje, kalibraciju, održavanje, odabir i specifikacije. Uključuje detaljne smjernice za precizno mjerenje pH.
Preview GREISINGER EBUW 232 EASYBUS Protocol Converter Operating Manual
Operating manual for the GREISINGER EBUW 232 EASYBUS protocol converter, detailing its specifications, general information, and safety requirements.
Preview GREISINGER GIA 20 EB / PK Uputstvo: Spajanje i rukovanje
Ovaj priručnik pruža sveobuhvatne upute za GREISINGER GIA 20 EB / PK mikroprocesorski kontrolirani uređaj za prikaz, nadzor i upravljanje. Obuhvata sigurnosne propise, električne veze za različite ulazne signale i tipove izlaza, konfiguraciju uređaja pomoću softvera, postavke preklopnih tačaka i alarma, podešavanje pomaka/nagiba, serijski interfejs, kodove grešaka, specifikacije i napomene o odlaganju.
Preview GREISINGER GMH 3710 Precizni termometar Uputstvo za upotrebu
Ovo uputstvo za upotrebu pruža detaljna uputstva za precizni termometar GREISINGER GMH 3710. Obuhvata namjenu, sigurnosne mjere opreza, specifikacije proizvoda, rukovanje, konfiguraciju, izlazne opcije, podešavanja ulaza, priključke sonde, osnovne principe mjerenja temperature, poruke o greškama i smjernice za odlaganje temperaturnih senzora Pt100.
Preview Greisinger GDH 200 serija manometara i barometara: Tehnički pregledview
Discover the Greisinger GDH 200 series handheld pressure measurement instruments. This document details the GDH 200-07 fine manometer, GDH 200-13 manometer, and GDH 200-14 vacuum/barometer, highlighting their specifications and features for professional use.
Preview GREISINGER GMH 38-LW1 / -LW2 Mjerač vlage - Uputstvo za upotrebu, Dodatak
Dodatak uputstvu za upotrebu za GREISINGER GMH 38-LW1 / -LW2 set za mjerenje vlage za poljoprivrednu primjenu. Obuhvata namjenu, sigurnost, opis proizvoda, rukovanje, principe mjerenja i specifikacije za drvnu sječku, žitarice, sijeno i slamu.