This manual provides essential information for the installation, configuration, operation, and maintenance of the ADTRAN Total Access 908E Gen 3 Router. This device is designed for carrier Ethernet and SIP/MGCP Voice over IP (VoIP) networks, offering robust routing and voice features for efficient IP service delivery.
2. Sigurnosne informacije
Pridržavajte se sljedećih sigurnosnih mjera opreza tokom instalacije i rada:
- Osigurajte da je uređaj instaliran u dobro prozračenom prostoru kako biste spriječili pregrijavanje.
- Koristite samo strujni adapter koji je isporučen s jedinicom.
- Ne izlažite uređaj vodi ili prekomjernoj vlazi.
- Izbjegavajte postavljanje uređaja u blizini izvora topline ili na direktnom suncu.
- Isključite napajanje prije čišćenja ili bilo kakvog održavanja.
3. Sadržaj paketa
Provjerite da li vaš paket sadrži sljedeće stavke:
- ADTRAN Total Access 908E Gen 3 Router (Model 4243908F2)
- Kabl za napajanje
- Rack Mounts (if applicable)
- Kabel za konzolu
4. Fizički overview
This section details the physical components and ports of the ADTRAN Total Access 908E Gen 3 Router.

Slika 1: ADTRAN Total Access 908E Gen 3 Router, illustrating the front and rear panels. The top image shows the front panel with LED indicators, while the bottom image displays the rear panel with various connectivity ports.
4.1 Indikatori na prednjoj ploči
The front panel of the router features several LED indicators to display the device's operational status:
- GLAS: Indicates the status of voice services.
- STATUS: Označava cjelokupno stanje sistema.
- GIG 1: Status for the Gigabit Ethernet port 1.
- USB: Označava aktivnost USB porta.
- T1 (1-4): Status for T1 interfaces 1 through 4.
- ETH 1, ETH 2: Status for Ethernet ports 1 and 2.
4.2 Priključci na zadnjoj ploči
The rear panel provides various connectivity options:
- VOICE (DB-25): Connector for voice services.
- FXO 0/0 (RJ-11): Foreign Exchange Office port for analog line connection.
- T1 0/1 - T1 0/4 (RJ-48C): Four T1/E1 interfaces for digital voice and data.
- ETH 0/1, ETH 0/2 (RJ-45): Fast Ethernet ports.
- GIG 0/1 (RJ-45): Gigabit Ethernet port (10/100/1000 BASE-T).
- USB: USB port for future expansion or configuration.
- CRAFT (DB-9): Console port for local management access.
- BBU: Battery Backup Unit connector.
- AC ULAZ: Ulazni konektor za napajanje.
5. Podešavanje
Follow these steps to set up your ADTRAN Total Access 908E Gen 3 Router:
5.1 Postavljanje
Place the router on a stable, flat surface or install it in a standard 19-inch equipment rack using the provided rack-mount brackets. Ensure adequate airflow around the unit.
5.2 Priključak za napajanje
- Spojite kabel za napajanje na AC INPUT port na zadnjoj ploči.
- Uključite drugi kraj kabla za napajanje u uzemljenu električnu utičnicu.
- The device will power on automatically. Observe the front panel LEDs for initial boot-up status.
5.3 Mrežne veze
Connect your network cables to the appropriate Ethernet ports:
- WAN veza: Connect your Internet service provider's Ethernet cable to the GIG 0/1 luka.
- LAN veze: Connect local network devices (e.g., switches, computers) to the ETH 0/1 or ETH 0/2 luke.
5.4 Voice Connections
Depending on your service, connect voice lines:
- Analog Lines: Connect analog telephone lines to the FXO 0/0 luka.
- Digital T1 Lines: Connect T1 lines to the T1 0/1 kroz T1 0/4 luke.
- Voice Equipment: Connect voice equipment to the GLAS port using the appropriate cable.
5.5 Console Connection (Optional)
For initial configuration or troubleshooting, connect a computer to the CRAFT port using the console cable.
6. Uputstvo za upotrebu
After physical setup, configure and operate the router.
6.1 Početno napajanje
Once connected to power, the router will initiate its boot sequence. Monitor the STATUS LED on the front panel. A steady green light typically indicates successful boot-up and operational status.
6.2 Pristup interfejsu za upravljanje
The ADTRAN Total Access 908E Gen 3 can be managed via a web-based Graphical User Interface (GUI) or a Command Line Interface (CLI) through the console port.
- Web GUI: Otvori a web browser and enter the router's default IP address (refer to your network administrator or product documentation for the specific IP). Enter the default username and password when prompted.
- CLI (Console): Use a terminal emulation program (e.g., PuTTY, Tera Term) on your computer connected to the CRAFT port. Configure the serial connection settings (e.g., baud rate 9600, 8 data bits, no parity, 1 stop bit, no flow control).
6.3 Osnovna konfiguracija
Refer to the comprehensive ADTRAN Operating System (AOS) documentation for detailed configuration instructions. Key configuration areas include:
- IP adresa: Configure WAN and LAN IP addresses, subnet masks, and default gateways.
- Rutiranje: Set up static routes or dynamic routing protocols.
- VoIP Settings: Configure SIP or MGCP parameters, including registrar servers, proxy servers, and dial plans.
- Firewall i sigurnost: Implement access control lists (ACLs) and other security features.
7. Održavanje
Redovno održavanje osigurava optimalne performanse i dugotrajnost vašeg rutera.
7.1 Ažuriranja firmvera
Periodically check the ADTRAN support website for the latest firmware versions. Updating firmware can provide new features, performance improvements, and security patches. Follow the instructions provided with the firmware package carefully.
7.2 Sigurnosno kopiranje i vraćanje konfiguracije
Regularly back up your router's configuration to an external storage device. This allows for quick restoration in case of accidental changes or system issues.
7.3 Čišćenje
Clean the exterior of the router with a soft, dry cloth. Do not use liquid cleaners or aerosol sprays. Ensure ventilation openings are free from dust and obstructions.
8. Otkrivanje problema
Ovaj odjeljak se bavi uobičajenim problemima s kojima se možete susresti.
8.1 Značenja LED indikatora
| LED | Status | Opis |
|---|---|---|
| STATUS | Solid Green | Sistem radi normalno. |
| STATUS | Treperi zeleno | Booting up or performing a task. |
| STATUS | Solid Red/Amber | System error or fault. |
| GLAS | Solid Green | Voice services are active. |
| GLAS | Isključeno | Voice services are inactive or not configured. |
| ETH/GIG | Solid Green | Veza uspostavljena. |
| ETH/GIG | Treperi zeleno | Aktivnost u luci. |
| ETH/GIG | Isključeno | Nijedan link ili port nisu onemogućeni. |
8.2 Uobičajeni problemi
- Nema napajanja: Ensure the power cord is securely connected to both the router and the electrical outlet. Verify the outlet is functional.
- Nema mrežne veze: Check Ethernet cable connections. Verify LED indicators for the connected ports. Confirm IP configuration settings.
- Voice Service Issues: Check T1/FXO line connections. Verify VoIP configuration settings (SIP/MGCP registration). Consult your service provider.
- Ne mogu pristupiti Web GUI: Ensure your computer is on the same network segment as the router. Verify the router's IP address and your computer's network settings. Try clearing your browser's cache.
9. Specifikacije
Key technical specifications for the ADTRAN Total Access 908E Gen 3 Router (Model 4243908F2):
- Brand: ADTRAN
- Broj modela: 4243908F2
- Hardverska platforma: PC
- Težina artikla: 8.32 funte
- Dimenzije proizvoda: 22.5 x 16.5 x 6 inča
- Boja: Crno/plavo
- Tehnologija povezivanja: Ethernet
- LAN Port Bandwidth: 10/100/1000 megabits per second (Gigabit Ethernet)
- Posebna karakteristika: WPS (Wireless Protected Setup - Note: This router is primarily wired, WPS may refer to a related feature or be a general specification from the source data)
- Uključene komponente: Router
- UPC: 607565037399
10. Garancija i podrška
ADTRAN products are typically covered by a limited warranty. For specific warranty terms and conditions, please refer to the documentation included with your purchase or visit the official ADTRAN website.
For technical assistance, product support, or to report issues, please contact ADTRAN customer support through their official channels. Have your product model number (4243908F2) and serial number ready when contacting support.