Uvod
This manual provides essential information for the installation, operation, and maintenance of the ICM Controls Upgraded Day & Night Furnace Control Circuit Board, Model HK42FZ013. This board is designed as a replacement for various Carrier, Bryant, and Payne main control circuit boards, including part numbers HK42FZ004, HK42FZ007, HK42FZ008, HK42FZ009, HK42FZ011, HK42FZ013, HK42FZ014, and HK42FZ016. It is crucial to read and understand all instructions before proceeding with installation or service.

Figure 1: ICM Controls HK42FZ013 Circuit Board and Wiring Harness. Nad glavom view of the green circuit board, showing various electronic components, relays, and terminal blocks. A multi-colored wiring harness is visible in the foreground, connected to a white connector, indicating its readiness for installation.
Sigurnosne informacije
Always prioritize safety when working with electrical and HVAC systems. Failure to follow these safety guidelines could result in property damage, personal injury, or death.
- Isključite napajanje: Before beginning any installation, maintenance, or troubleshooting, ensure that all electrical power to the furnace and associated equipment is completely disconnected at the main service panel. Verify power is off using a voltage metar.
- Kvalificirano osoblje: Installation and service should only be performed by qualified, experienced HVAC technicians.
- statičko pražnjenje: Handle the circuit board by its edges to avoid damage from electrostatic discharge (ESD). Consider using an anti-static wrist strap.
- Ožičenje: Osigurajte da su svi spojevi ožičenja sigurni i da su u skladu s lokalnim i nacionalnim električnim propisima.
- Integritet komponenti: Do not operate the furnace if any components appear damaged or if there are signs of overheating.
Postavljanje i instalacija
This replacement board is designed for straightforward installation, often requiring minor wiring adjustments facilitated by the included wiring harness. Refer to the specific instructions provided with your board for detailed wiring diagrams and configuration settings.
- Isključivanje struje: Turn off all power to the furnace at the circuit breaker or fuse box.
- Access Furnace Control Area: Otvorite pristupnu ploču peći kako biste otkrili postojeću upravljačku ploču.
- Dokumentujte postojeće ožičenje: Prije odspajanja bilo koje žice, napravite jasne fotografije ili detaljne dijagrame svih postojećih ožičenja na staroj ploči. Zabilježite položaj i boju svake žice.
- Isključite staru ploču: Pažljivo odspojite sve žice i montažni pribor sa stare upravljačke ploče.
- Instalirajte novu ploču: Mount the new HK42FZ013 board in the same location as the old board.
- Povežite ožičenje: Using your documented wiring and the included wiring harness, connect all wires to the new board. Pay close attention to the terminal labels (e.g., G, Y, W, R, C, 24V, L1, Neutral). The included harness facilitates necessary changes for compatibility.
- Sigurne veze: Ensure all spade connectors are firmly seated and screw terminals are tightened appropriately.
- Zatvori pristupnu ploču: Čvrsto zatvorite pristupnu ploču peći.
- Vrati snagu: Turn on the power to the furnace at the main service panel.
- Probni rad: Pokrenite ciklus zagrijavanja kako biste provjerili ispravan rad peći.
Operativni principi
The HK42FZ013 control board manages the sequence of operations for your furnace, including ignition, fan control, and safety monitoring. Once installed, the board operates automatically based on signals from the thermostat and internal sensors.
- Thermostat Input: The board receives calls for heat or fan operation from the connected thermostat.
- Redoslijed paljenja: Upon a call for heat, the board initiates the ignition sequence, which typically involves proving the draft, energizing the igniter, opening the gas valve, and proving flame.
- Kontrola ventilatora: The board controls the circulation blower fan based on heating/cooling demands and timed delays.
- Sigurnosni nadzor: Integrated safety circuits continuously monitor furnace operation, including flame sensing, limit switches, and pressure switches. If a fault is detected, the board will shut down the furnace and typically display a diagnostic code.
Održavanje
The HK42FZ013 circuit board itself requires no routine maintenance. However, regular maintenance of the overall furnace system is crucial for its longevity and efficient operation. Always disconnect power before performing any maintenance.
- Zamjena filtera zraka: Regularly inspect and replace the furnace air filter according to the manufacturer's recommendations (typically every 1-3 months). A dirty filter restricts airflow and can cause the furnace to overheat.
- Godišnji stručni pregled: Schedule an annual inspection and tune-up by a qualified HVAC technician. They can clean components, check electrical connections, verify proper operation, and identify potential issues before they become major problems.
- Clear Vents and Returns: Ensure that all supply and return air vents are unobstructed.
Rješavanje problema
The HK42FZ013 board features a status code LED (visible on the board, labeled "STATUS CODE LED") to assist in diagnosing furnace issues. Refer to your furnace's specific diagnostic code chart for detailed interpretations. Below are general troubleshooting steps.
| Simptom | Mogući uzrok | Akcija |
|---|---|---|
| Furnace not heating / No power | No power to furnace; tripped breaker; blown fuse; thermostat issue. | Check circuit breaker/fuse. Ensure thermostat is set to heat and temperature is above ambient. Verify power supply to the board. |
| Furnace cycles on and off rapidly (short cycling) | Restricted airflow (dirty filter); clogged vents; overheating; faulty limit switch. | Replace air filter. Ensure all vents are open. Check for obstructions in ductwork. Consult a technician if issue persists. |
| Ventilator radi neprestano | Thermostat fan setting; faulty fan limit switch; board issue. | Check thermostat fan setting (should be "Auto"). If set to "Auto" and fan still runs, a component may be stuck or faulty. |
| No ignition / Burners not lighting | No gas supply; faulty igniter; dirty flame sensor; pressure switch issue. | Ensure gas valve is open. Clean flame sensor. Check diagnostic codes on the board's LED. |
| Diagnostic LED flashing a code | Specific fault detected by the board. | Count the flashes and consult your furnace's specific diagnostic code chart (often found on the furnace door or in its manual) to identify the fault. |
Napomena: Za složene probleme ili ako niste sigurni u vezi s bilo kojim korakom, preporučuje se da kontaktirate ovlaštenog HVAC tehničara.
Specifikacije
| Atribut | Detalj |
|---|---|
| Proizvođač | ICM kontrole |
| Broj dijela | HK42FZ013 |
| Težina artikla | 14.4 unce |
| Dimenzije paketa | 8.82 x 6.3 x 4.41 inča |
| Kompatibilnost | Replaces HK42FZ004, HK42FZ007, HK42FZ008, HK42FZ009, HK42FZ011, HK42FZ013, HK42FZ014, HK42FZ016. Compatible with various Carrier, Bryant, and Payne models (e.g., Bryant 359MA-F, Carrier 58MX0-5). |
| Prvi raspoloživi datum | 5. juna 2010 |
Garancija i podrška
For specific warranty information regarding your ICM Controls HK42FZ013 circuit board, please refer to the documentation included with your purchase or contact ICM Controls directly. Support for installation and troubleshooting can often be found through the manufacturer's official website or by consulting a qualified HVAC professional.
Za tehničku pomoć ili upite, posjetite Službenik ICM Controls-a website.