This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Einhell House Waterworks GE-WW 5537 E. Please read these instructions carefully before using the device for the first time and keep them for future reference. This house waterworks system is designed for pumping clear water from reservoirs, wells, and shafts to supply irrigation systems, washing machines, toilets, and similar applications.

Einhell House Waterworks GE-WW 5537 E

Figure 1: Einhell House Waterworks GE-WW 5537 E. This image shows the complete house waterworks unit, featuring the red pump housing, black motor, clear pre-filter, and the silver 20-liter pressure tank.

2. Sigurnosna uputstva

Uvijek se pridržavajte sljedećih sigurnosnih mjera opreza kako biste spriječili ozljede i oštećenje opreme:

3. Proizvod je gotovview

The Einhell House Waterworks GE-WW 5537 E is designed for efficient water supply with several key features:

3.1 Ključne komponente

Pre-filter and inlet connection

Figure 2: Pre-filter and Inlet. This close-up shows the transparent pre-filter housing and the threaded inlet connection, designed to protect the pump from debris.

Manometar pritiska

Figure 3: Pressure Manometer. A detailed view of the integrated manometer, which displays the current system pressure in bar and psi for easy monitoring.

Water Filling Opening

Figure 4: Water Filling Opening. This image highlights the large, easily accessible opening for filling the pump with water before initial operation or after maintenance.

Čep za odvod vode

Figure 5: Water Drain Plug. A close-up of the red drain plug located at the bottom of the pump, used for completely emptying the unit, especially for winterization.

4. Tehničke specifikacije

FeatureSpecifikacija
ModelGE-WW 5537 E
Snaga590 W
Max. Kapacitet protoka3750 l/h
Max. Pritisak3.8 bara
Pressure Container Volume20 litar
Voltage230 V
Frekvencija50 Hz
Max. Visina usisavanja8 m
Maks. Visina isporuke38 m
Pressure Tank MaterialStainless Steel (as specified)
Težina11.91 kg
Performance Curve Diagram

Figure 6: Performance Curve. This graph illustrates the relationship between the delivery height (H in meters) and the flow rate (Q in liters per hour) for the GE-WW 5537 E.

5. Podešavanje

5.1 Postavljanje

Place the house waterworks on a firm, level surface, protected from frost and direct sunlight. Ensure adequate ventilation around the unit.

5.2 Connecting Suction Line

Connect a suction hose (minimum 1 inch diameter) to the pump's inlet. Ensure all connections are airtight to prevent air ingress, which can impair pump performance. It is recommended to use a foot valve with a filter at the end of the suction hose in the water source.

5.3 Connecting Pressure Line

Connect the pressure line to the pump's outlet. Use appropriate fittings and ensure secure, leak-free connections.

5.4 Filling the Pump

Before initial operation, the pump housing must be completely filled with water. Open the water filling opening (Figure 4) and pour water until the housing is full. Close the opening securely.

5.5 Električni priključak

Connect the power plug to a properly installed and grounded electrical outlet (230V, 50Hz). Ensure the electrical circuit is protected by a residual current device (RCD).

Tipični dijagram instalacije

Figure 7: Typical Installation. This diagram illustrates a common setup for the house waterworks, showing the maximum suction height (H max: 8m) and maximum delivery height (H max: 38m), along with the pressure tank and connections.

6. Operacija

6.1 Pokretanje pumpe

After filling the pump and ensuring all connections are secure, switch on the power. The pump will start and build up pressure in the system. The manometer (Figure 3) will display the current pressure.

6.2 Automatski rad

The integrated pressure switch automatically turns the pump on when the pressure in the system drops (e.g., when a tap is opened) and turns it off when the maximum pressure is reached. The 20-liter pressure tank reduces the frequency of pump cycles, extending its lifespan and saving energy.

ECO Power Technology Diagram

Figure 8: ECO Power Technology. This diagram visually compares past energy consumption for a given delivery rate with the current ECO Power technology, highlighting up to 10% energy savings.

7. Održavanje

Regular maintenance ensures optimal performance and longevity of your house waterworks.

7.1 Čišćenje predfiltera

Periodically check and clean the integrated pre-filter (Figure 2). To do this, disconnect the power, relieve system pressure, unscrew the filter housing, remove and clean the filter insert under running water. Reassemble carefully, ensuring the O-ring is correctly seated.

7.2 Zimovanje

Before the first frost, completely drain the house waterworks to prevent damage from freezing water. Disconnect the power, open all taps in the pressure line, and remove the water drain plug (Figure 5) to empty the tank and pump housing. Store the unit in a frost-free location.

7.3 Generalno čišćenje

Očistite vanjski dio jedinice s oglasomamp tkanina. Nemojte koristiti agresivna sredstva za čišćenje.

8. Otkrivanje problema

Evo nekih uobičajenih problema i njihovih potencijalnih rješenja:

ProblemMogući uzrokRješenje
Pumpa se ne pokrećeNo power supply; Motor overload; Pressure switch faultCheck power connection/fuse; Allow motor to cool; Consult service technician
Pumpa radi, ali voda se ne isporučujePump not filled; Air in suction line; Suction height too high; Foot valve blockedFill pump with water; Check suction line for leaks; Reduce suction height; Clean foot valve
Nizak pritisak ili protokPre-filter clogged; Air in system; Leak in pressure line; Insufficient water supplyClean pre-filter; Bleed system; Check for leaks; Ensure adequate water source
Pump switches on and off frequentlyLeak in pressure system; Pressure tank pre-charge pressure incorrect; Pressure switch faultyCheck for leaks; Check/adjust pressure tank pre-charge; Consult service technician

If you cannot resolve the issue using this table, please contact customer support.

9. Jamstvo i podrška

Einhell products are manufactured with care and undergo strict quality controls. This product is covered by a manufacturer's warranty. Please refer to the warranty card included with your purchase for specific terms and conditions, including the warranty period and claim procedures. For technical support, spare parts, or warranty claims, please contact your authorized Einhell dealer or visit the official Einhell webstranica za kontakt informacije za korisničku podršku.

Sačuvajte račun kao dokaz o kupovini u slučaju eventualnih reklamacija.

Povezani dokumenti - GE-WW 5537 E

Preview Einhell GE-DP 7535 N LL ECO Schmutzwasserpumpe / Flutset Bedienungsanleitung
Diese Anleitung beschreibt die Bedienung und Wartung der Einhell GE-DP 7535 N LL ECO Schmutzwasserpumpe und des Flutsets. Sie enthält wichtige Sicherheitshinweise, technische Daten und Anleitungen zur Fehlerbehebung für den effizienten Einsatz der Pumpe.
Preview Einhell GE-CF 18/2200 Li bežični ventilator - uputstvo za upotrebu
Otkrijte Einhell GE-CF 18/2200 Li bežični ventilator. Ovo uputstvo za upotrebu detaljno opisuje njegove karakteristike za ventilaciju domaćinstva, uključujući bežično napajanje, podesive brzine i prenosivost. Saznajte više o sigurnom radu, održavanju i garanciji.
Preview Einhell GE-SP 18 Li Akku-Klarwasserpumpe Bedienungsanleitung
Die offizielle Bedienungsanleitung für die Einhell GE-SP 18 Li Akku-Klarwasserpumpe. Enthält detaillierte Informationen zu Sicherheit, Installation, Betrieb, Wartung und Fehlerbehebung für dieses leistungsstarke Gartengerät.
Preview Einhell GE-WS 18/35 Li & GE-WS 18/75 Li Akku-Drucksprühgerät Bedienungsanleitung
Diese Bedienungsanleitung für die Einhell Akku-Drucksprühgeräte GE-WS 18/35 Li i GE-WS 18/75 Li bietet detaillierte Anleitungen zur sicheren Verwendung, Wartung und Fehlerbehebungä dieser Garte.
Preview Einhell GE-PP 18 RB Li Akku-Tauchdruckpumpe: Bedienungsanleitung
Umfassende Bedienungsanleitung für die Einhell GE-PP 18 RB Li Akku-Tauchdruckpumpe. Erfahren Sie alles über Installation, sichere Bedienung, technische Daten und Wartung dieses kabellosen Geräts für Haus und Garten.
Preview Einhell GE-CL 36 Li E bežični usisivač Upute za upotrebu
Sveobuhvatna uputstva za upotrebu i sigurnosne smjernice za Einhell GE-CL 36 Li E bežični usisivač, s detaljnim opisom montaže, upotrebe, održavanja i rješavanja problema.