Riello 3007771/RI

Riello Gulliver RG1 Oil Burner Pump Instruction Manual

Model: 3007771/RI

Uvod

This instruction manual provides essential information for the safe and correct use, installation, and maintenance of the Riello Gulliver RG1 Oil Burner Pump, model 3007771/RI. This pump is designed for use with Riello RDB, Unit, Gulliver RG0 (358T1 - 359T1 - 360T1), Gulliver RG1 (363T1), and Gulliver RG2 (377T1) series oil burners. Please read this manual thoroughly before any operation or service.

Važne informacije o sigurnosti

WARNING: Risk of injury or equipment damage.

The replacement of spare parts on boilers or boiler burners must be carried out with extreme caution. To ensure the safety and proper functioning of your appliance, it is strongly recommended that this operation be performed by a qualified technician. Incorrect installation can lead to risks of malfunction, safety hazards, and potential damage to the heating system or property.

This product is sold in its original manufacturer's packaging and has not undergone any modifications. Due to the nature of this product, professional installation is highly recommended.

Product Overview

The Riello Gulliver RG1 Oil Burner Pump (model 3007771/RI) is a critical component for various Riello oil burners. It is designed to deliver fuel efficiently and reliably to the burner. This specific pump is supplied without a coil, which must be acquired separately if needed.

Riello Gulliver RG1 Oil Burner Pump

Slika 1: Front view of the Riello Gulliver RG1 Oil Burner Pump. The pump features a metallic housing with visible hex screws and a central brass shaft. The front plate is marked "R.B.L." with directional arrows, indicating flow. This image shows the robust construction and key external features of the pump.

Tehničke specifikacije

FeatureDetalj
ProizvođačRiello
Broj modela3007771/RI
KompatibilnostRiello RDB, Unit, Gulliver RG0 (358T1 - 359T1 - 360T1), Gulliver RG1 (363T1), Gulliver RG2 (377T1)
Shaft Diameter8 mm
RotacijaD (Right)
Pritisak12 bara
Hub32 mm
d_bit36
Coil IncludedNo (delivered without coil)

Instalacija

As highlighted in the safety information, the installation of the Riello Gulliver RG1 pump requires specialized knowledge and should only be performed by a qualified and certified technician. Incorrect installation can lead to severe operational issues, safety hazards, and void any warranties.

General steps for a qualified technician typically include:

  1. Isključivanje struje: Ensure the main power supply to the burner and heating system is completely disconnected and locked out.
  2. Fuel Line Isolation: Close fuel supply valves to prevent spills.
  3. Old Pump Removal: Carefully disconnect fuel lines and electrical connections from the old pump. Remove mounting bolts and extract the old pump.
  4. New Pump Installation: Mount the new Riello Gulliver RG1 pump securely, ensuring proper alignment with the burner shaft.
  5. Veze: Reconnect fuel lines, ensuring all fittings are tight and leak-free. Reconnect electrical wiring according to the burner's wiring diagram.
  6. Prajming: Follow the burner manufacturer's instructions for priming the fuel system to remove air.
  7. Leak Check & Testing: Restore power and carefully check for any fuel leaks. Test the burner operation, monitoring fuel pressure and combustion.

Always refer to the specific installation instructions provided with your Riello burner model for detailed steps and safety precautions.

Operacija

The Riello Gulliver RG1 pump operates as part of the oil burner system, drawing fuel from the tank and delivering it at a precise pressure to the nozzle for atomization and combustion. Once installed correctly, the pump's operation is typically automatic, controlled by the burner's control unit.

Održavanje

Proper maintenance is crucial for the longevity and efficient operation of your Riello Gulliver RG1 pump and the entire heating system. Maintenance should be performed by a qualified technician.

Rješavanje problema

If you experience issues with your oil burner, the pump may be a contributing factor. Always consult a qualified technician for diagnosis and repair.

ProblemMogući uzrokAction (for qualified technician)
Gorionik se ne uspijeva zapalitiNo fuel delivery, low fuel pressure, air in fuel lines, clogged filter.Check fuel level, prime pump, inspect/replace filter, check pump pressure.
Burner cycles on/off frequentlyInconsistent fuel pressure, air in system.Check for air leaks, verify pump pressure stability.
Oil leaks from pumpDamaged shaft seal, loose fittings.Inspect and replace seals, tighten connections.
Neobična buka iz pumpeAir in system, worn bearings, cavitation.Bleed air, inspect pump internals for wear.

Do not attempt to repair the pump yourself if you are not a qualified technician. Contact a professional for all troubleshooting and repair needs.

Garancija i podrška

Information regarding specific warranty terms for the Riello Gulliver RG1 pump (model 3007771/RI) is not available in this document. Please refer to your purchase documentation or contact your supplier or a certified Riello service center for warranty details and technical support.

For spare parts availability, the provided information states "Information indisponible sur les pièces détachées" (Information unavailable on spare parts). It is recommended to contact Riello directly or an authorized distributor for spare part inquiries.

Povezani dokumenti - 3007771/RI

Preview Popis dijelova i dijagram uljnog plamenika Riello Gulliver RG2F
Detaljan popis rezervnih dijelova i dijagram komponenti za Riello Gulliver RG2F gorionik na lako ulje (Model 377T1, Šifra 3737770), uključujući brojeve dijelova i opise na engleskom jeziku.
Preview Priročnik za upotrebu, upotrebu i održavanje gorilnika RIELLO Gulliver RG1NR na plinskom olju
Ovaj dokument sadrži detaljne upute za ugradnju, korištenje, održavanje i popravljanje grešaka enostopenskog gorilnika RIELLO Gulliver RG1NR na plinsko ulje, uključujući tehničke podatke, sigurnosne predpise u postupcima za rješavanje problema.
Preview Riello 40 Serija kućnih uljnih plamenika F3 i F5 Uputstvo za instalaciju
Ovaj priručnik pruža detaljne upute za instalaciju Riello 40 serije kućnog ulja, modela F3 i F5. Obuhvata identifikaciju komponenti, podešavanje, montažu, električne priključke, postavljanje mlaznica i postupke podešavanja. Priručnik je namijenjen za naknadnu ugradnju i uključuje tehničke podatke, specifikacije i popise rezervnih dijelova.
Preview Riello 40 BF Single Stage Uputstvo za instalaciju i upotrebu uljnog plamenika
Sveobuhvatno uputstvo za instalaciju i upotrebu za Riello 40 BF single-stage uljni gorionik, koji obuhvata tehničke specifikacije, postupke instalacije, dijagrame ožičenja, rješavanje problema i rezervne dijelove.
Preview Riello 40 serija F3 i F5 Uputstvo za instalaciju kućnog uljnog plamenika
Sveobuhvatni priručnik za instalaciju Riello 40 serije kućnog ulja, modela F3 i F5. Obuhvata tehničke podatke, identifikaciju komponenti, podešavanje, montažu, električne priključke, konfiguraciju uljnih vodova, ispiranje pumpe, podešavanja i rezervne dijelove.
Preview Riello 40 G10 Uputstvo za ugradnju i održavanje gorionika na lako ulje
Ovaj dokument pruža sveobuhvatne upute za instalaciju, upotrebu i održavanje gorionika na lako ulje Riello 40 G10. Uključuje tehničke podatke, dijagrame, sheme električnih ožičenja i postupke podešavanja sagorijevanja.