Uvod
This manual provides detailed instructions for the installation, operation, and maintenance of your ELKAY 400A Columbus Pneumatic Timer. This device is designed to automatically switch off lighting after a user-defined period, offering a practical solution for energy management.
Važne informacije o sigurnosti
WARNING: Risk of electric shock. Installation should only be performed by a qualified electrician or competent person in accordance with national wiring regulations.
- Always disconnect power at the main circuit breaker before installing or servicing the timer.
- Osigurajte da su svi spojevi ožičenja sigurni i pravilno izolirani.
- Do not exceed the maximum load ratings specified for this device.
- Ovaj proizvod je dizajniran samo za upotrebu u zatvorenom prostoru.
- Čuvati van domašaja djece.
Product Overview
The ELKAY 400A Columbus Pneumatic Timer is a single-contact, push-button operated timer. It is designed to replace standard single-gang wall switches and does not require a neutral connection. The timer provides an adjustable delay period, automatically turning off connected lighting after the set time has elapsed.

Slika 1: Prednja strana view of the ELKAY 400A Columbus Pneumatic Timer. Shows the white ABS casing and the central push-button mechanism.
Ključne karakteristike:
- Automatsko isključivanje: Turns off lighting after a set time.
- Podesivo vremensko kašnjenje: Configurable from approximately 5 seconds to 5 minutes.
- Jednostavna instalacija: Replaces existing single-gang wall switches.
- No Neutral Required: Simplifies wiring.
- Kompatibilnost: Suitable for fluorescent (up to 6 fittings) and incandescent lighting.
- Izdržljiva konstrukcija: Made from Acrylonitrile Butadiene Styrene (ABS).
Uputstva za instalaciju
- Isključivanje struje: Before beginning installation, ensure the electrical supply to the circuit is completely disconnected at the consumer unit/fuse box. Verify with a suitable voltage tester.
- Uklonite postojeći prekidač: Carefully remove the existing wall switch from its mounting box. Note the wiring connections.
- Ožičenje:
- Connect the incoming live wire to the terminal marked 'L' or 'IN' on the ELKAY 400A timer.
- Connect the switched live wire (going to the light fitting) to the terminal marked 'SW' or 'OUT' on the ELKAY 400A timer.
- Note: This timer does not require a neutral connection.
- Podešavanje vremenskog kašnjenja:
The time delay is adjusted via a small screw located on the rear of the timer mechanism. Use a small screwdriver to turn this screw. Turning clockwise typically increases the time, and counter-clockwise decreases it. The timing range is approximately 5 seconds to 5 minutes. Adjust this setting before fully mounting the timer.
Note: Timings are approximate and may require fine-tuning after initial power-up.
- Montaža: Carefully place the wired timer into the wall mounting box, ensuring no wires are pinched. Secure the timer to the box using the provided screws. Attach the faceplate.
- Ponovno priključivanje napajanja: Restore power to the circuit at the consumer unit/fuse box.
- testiranje: Press the timer button to activate. Observe the connected lighting and verify that it switches off after the set delay. Adjust the time delay screw further if necessary (repeat steps 1, 4, 6, 7).
For optimal performance, ensure the mounting surface is flat and does not exert undue pressure on the timer mechanism, which could affect timing accuracy.
Uputstvo za upotrebu
To operate the ELKAY 400A Columbus Pneumatic Timer, simply press the central button. This action will switch on the connected lighting and simultaneously activate the internal pneumatic delay mechanism. The lighting will remain on for the pre-set duration (between 5 seconds and 5 minutes) and then automatically switch off.
- A single press activates the timer.
- The timer cannot be manually turned off before the delay period expires.
- Pressing the button again during an active cycle will restart the timer, extending the light-on period.
Održavanje
The ELKAY 400A Pneumatic Timer requires minimal maintenance. To ensure longevity and proper function:
- čišćenje: Wipe the surface with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure power is off before cleaning.
- inspekcija: Periodically check for any signs of damage or loose connections. If any issues are found, disconnect power and consult a qualified electrician.
- Nema dijelova koje korisnik može servisirati: Do not attempt to open or repair the internal mechanism of the timer. This will void any warranty and could lead to electric shock.
Rješavanje problema
| Problem | Mogući uzrok | Rješenje |
|---|---|---|
| Timer does not activate lights. |
|
|
| Lights do not turn off, or turn off too quickly/slowly. |
|
|
| Inconsistent timing. |
|
|
Specifikacije proizvoda
- Model: 400A
- Brand: Elkay
- Materijal: akrilonitril butadien stiren (ABS)
- Boja: Bijelo
- Dimenzije proizvoda (D x Š x V): 2.17" x 3.35" x 3.35" (približno 55 mm x 85 mm x 85 mm)
- Težina artikla: 3.87 ounces (110g approx.)
- Raspon vremenskog kašnjenja: Approximately 5 seconds to 5 minutes (adjustable)
- Tip prekidača: Single Contact, Pneumatic
- Neutral Requirement: Nije potrebna neutralnost
- Kompatibilnost rasvjete:
- Rasvjeta sa žarnom niti
- Fluorescent lighting (maximum 6 fittings)
- Certifikati: CE, IEC 60669-2-1:2002, RoHS compliant
- Uključene komponente: 1 x Columbus Pneumatic Timer - Single Contact - 400A
Garancija i korisnička podrška
For warranty information or technical assistance, please contact Elkay customer support. Keep your purchase receipt as proof of purchase.
Elkay korisnička podrška: Please refer to the official Elkay webkontakt podatke potražite na web-mjestu ili na pakiranju proizvoda.