1. Uvod
The Riello IDG 1200 is a compact and reliable Uninterruptible Power Supply (UPS) designed to protect your electronic devices from power outages and fluctuations. It provides a stable power source, ensuring continuous operation and safeguarding your equipment from potential damage. This manual provides essential information for the proper installation, operation, and maintenance of your Riello IDG 1200 UPS.

This image shows the Riello IDG 1200 UPS unit from a front-side angle. The device is black, compact, and designed for vertical placement. The front panel features the 'Riello iDialog UPS' logo. Ventilation grilles are visible on the side.
2. Podešavanje
2.1 Raspakivanje
Carefully remove the UPS from its packaging. Inspect the unit for any signs of damage that may have occurred during transit. Retain the packaging for future transport or storage.
2.2 Postavljanje
Due to its compact form factor, the Riello IDG 1200 can be positioned almost anywhere. Ensure the chosen location is:
- Well-ventilated, allowing for proper heat dissipation.
- Away from direct sunlight, heat sources, and excessive humidity.
- Na stabilnoj, ravnoj površini.
2.3 Povezivanje UPS-a
- Spojite kabel za napajanje UPS-a na uzemljenu zidnu utičnicu.
- Connect your computer, monitor, and other critical devices to the output sockets on the rear of the UPS. Ensure the total power consumption of connected devices does not exceed the UPS's capacity (720W).
- For advanced monitoring and management, connect the UPS to your computer via the appropriate communication port (e.g., USB, if available).
2.4 Instalacija softvera (opcionalno)
The Riello IDG 1200 is compatible with various operating systems, including Windows Vista, 2003, XP, 2000, Me, 98, Linux, Mac OSX, and Sun Solaris. For enhanced control and monitoring features, install the Riello UPS management software on your computer. Refer to the software's documentation for installation instructions.
3. Uputstvo za upotrebu
3.1 Uključivanje UPS-a
Press and hold the power button on the front panel for a few seconds until you hear a beep and the indicators light up. The UPS will perform a self-test and then enter normal operating mode.
3.2 Isključivanje UPS-a
To turn off the UPS, press and hold the power button again until the indicators turn off and you hear a final beep. Ensure all connected devices are properly shut down before turning off the UPS.
3.3 Automatsko ponovno pokretanje
The Riello IDG 1200 features an automatic restart function. After a power outage and when utility power is restored, the UPS will automatically restart and resume providing power to connected devices, provided the battery has sufficient charge.
3.4 Baterijski način rada
When utility power fails, the UPS will automatically switch to battery mode, providing backup power to connected devices. An audible alarm may sound to indicate that the UPS is operating on battery power. The alarm will typically become more frequent as the battery charge depletes.
4. Održavanje
4.1 Njega baterija
The UPS contains sealed lead-acid batteries. To maximize battery life:
- Keep the UPS connected to a power outlet to ensure the batteries remain fully charged.
- Avoid storing the UPS in extreme temperatures.
- Perform a battery self-test periodically (if supported by the management software) to assess battery health.
- The typical battery recharge time is approximately 8 hours.
4.2 Čišćenje
Očistite vanjski dio UPS-a mekom, suhom krpom. Ne koristite tekuća ili aerosolna sredstva za čišćenje. Osigurajte da ventilacijski otvori budu bez prašine i začepljeni.
4.3 Zamjena baterije
Battery replacement should only be performed by qualified service personnel. Refer to the manufacturer's guidelines for battery replacement procedures and compatible battery types.
5. Otkrivanje problema
This section provides solutions to common issues you might encounter with your Riello IDG 1200 UPS. If the problem persists after attempting these solutions, please contact customer support.
| Problem | Mogući uzrok | Rješenje |
|---|---|---|
| UPS se ne uključuje. | No input power; Battery deeply discharged. | Ensure the power cord is securely plugged into a live wall outlet. Allow the UPS to charge for at least 8 hours before attempting to turn it on. |
| UPS neprekidno pišti u normalnom režimu. | Stanje preopterećenja. | Disconnect non-essential equipment from the UPS until the alarm stops. Ensure total load does not exceed 720W. |
| UPS se često prebacuje na baterijski način rada. | Unstable utility power; Sensitivity setting too high. | Check your utility power supply. If using management software, adjust the UPS sensitivity setting (refer to software manual). |
| Kratko vrijeme sigurnosne kopije. | Baterija je stara ili nije potpuno napunjena; Preopterećenje. | Allow the UPS to charge for 8 hours. Reduce the connected load. Consider battery replacement if the battery is old. |
6. Specifikacije
| Feature | Specifikacija |
|---|---|
| Brand | Riello |
| Broj modela | IDG 1200 |
| Serije | iDialog |
| Izlazna snaga | 1200 VA / 720 W |
| Voltage | 1200 Volts (Input/Output nominal) |
| Boja | Crna |
| Materijal | Metal |
| Dimenzije proizvoda | 9.3 x 31 x 27 cm |
| Težina artikla | 3.7 kilograma |
| Vrsta baterije | Lead Acid, AGM |
| Vrijeme punjenja baterije | 8 sata |
| Form Factor | Compact |
| Prvi raspoloživi datum | 3. januara 2012 |
7. Šta se nalazi u kutiji
The Riello IDG 1200 package typically includes:
- Riello IDG 1200 UPS Unit
- Power Cables
- Korisnički priručnik (ovaj dokument)
- Communication Cable (e.g., USB cable for software connection)
8. Garancija i podrška
Za informacije o garanciji, tehničkoj podršci ili upite o servisiranju, molimo pogledajte garantni list koji ste dobili uz proizvod ili posjetite službenu Riello stranicu. webSačuvajte račun kao dokaz o kupovini za reklamacije u slučaju reklamacije.
Riello Official Webstranica: www.riello-ups.com