1. Uvod
This manual provides essential information for the safe and efficient operation of your Steinbach SPS 75-1 Filter Pump. This self-priming pump is designed for use with pool filter systems, capable of handling pools up to 33,000 liters. It features a robust 230 V/450 W motor and a pump capacity of 8,520 liters per hour (142 l/min).
Molimo vas da pažljivo pročitate ovaj priručnik prije instalacije i rada kako biste osigurali pravilnu upotrebu i spriječili oštećenje uređaja ili povrede.
2. Sigurnosna uputstva
Uvijek se pridržavajte sljedećih sigurnosnih mjera opreza kako biste smanjili rizik od požara, strujnog udara ili ozljede.
- električna sigurnost: Ensure the pump is connected to a properly grounded outlet. Do not operate the pump with a damaged power cord or plug. Disconnect power before performing any maintenance or service.
- Temperatura vode: The pump is designed for a maximum water temperature of 35°C (95°F). Operating above this temperature can cause damage to the pump.
- plasman: Install the pump on a stable, level surface, away from direct sunlight and excessive moisture. Ensure adequate ventilation around the motor.
- Djeca i kućni ljubimci: Držite djecu i kućne ljubimce dalje od pumpe tokom rada.
- Održavanje: Only perform maintenance as described in this manual. For complex repairs, consult a qualified technician.
3. Podešavanje
Slijedite ove korake za pravilnu instalaciju filter pumpe.
- Raspakivanje: Carefully remove all components from the packaging. Inspect the pump for any signs of damage during transit.
- plasman: Position the pump as close to the pool as possible, ensuring it is below the water level for optimal self-priming. The pump should be on a firm, level surface to prevent vibration.
- Priključci crijeva: Connect the pool hoses to the pump's inlet and outlet ports. The pump supports hose diameters of 32mm and 38mm. Ensure all connections are tight to prevent leaks and maintain prime.

Slika 3.1: Krupni plan view of the pre-filter inlet with a hose connection, showing the clear cover and filter basket.

Figure 3.2: The pre-filter inlet without a hose attached, illustrating the threaded connection for secure fitting.

Figure 3.3: The pump's outlet connection with a hose securely fastened, ready for water discharge.

Figure 3.4: The pump's outlet port, showing the internal threading for hose attachment.

Figure 3.5: An overall perspective of the Steinbach SPS 75-1 Filter Pump, highlighting its compact design and key components.
- Punjenje pumpe: As a self-priming pump, it will draw water once connected. However, for initial startup, it is recommended to fill the pre-filter housing with water to assist in faster priming.
- Električni priključak: Plug the pump into a suitable 230V electrical outlet. Ensure the circuit is protected by a Residual Current Device (RCD) for safety.
4. Uputstvo za upotrebu
Once installed, operating the pump is straightforward.
- Pokretanje pumpe: Turn on the power supply to the pump. The pump will begin to draw water and circulate it through your filter system.
- Nadgledanje: Observe the pump during its initial operation to ensure there are no leaks and that water is flowing correctly. The pump operates at approximately 70 dB.
- Zaustavljanje pumpe: Isključite napajanje pumpe.
- Vrijeme rada: The optimal run time for your pump depends on your pool size and usage. For a 33,000-liter pool, ensure sufficient daily filtration to maintain water clarity.
5. Održavanje
Regular maintenance ensures the longevity and efficiency of your pump.
- Čišćenje predfiltera: The pump is equipped with a pre-filter to catch larger debris. Regularly inspect and clean the pre-filter basket. To do this, turn off the pump, disconnect power, unscrew the clear lid, remove the basket, clean it, and reassemble. Ensure the O-ring is properly seated for a watertight seal.
- Zimljenje: Before freezing temperatures, drain all water from the pump and hoses. Store the pump in a dry, frost-free location.
- Generalno čišćenje: Keep the exterior of the pump clean and free from dirt and debris. Do not use harsh chemicals.
6. Otkrivanje problema
If you encounter issues with your pump, refer to the following common problems and solutions.
| Problem | Mogući uzrok | Rješenje |
|---|---|---|
| Pumpa se ne pokreće | Nema napajanja Preopterećenje motora Radno kolo je zaglavljeno | Provjerite priključak za napajanje i osigurač Ostavite motor da se ohladi, provjerite ima li prepreka Inspect and clear impeller |
| Nizak protok vode | Začepljen predfilter Curenje zraka u usisnom vodu Nizak nivo vode u bazenu | Clean pre-filter basket Provjerite nepropusnost svih priključaka Dodajte vodu u bazen |
| Pumpa je bučna | Vazduh u sistemu Vibracije Istrošeni ležajevi | Bleed air from system, check for leaks Ensure pump is on a stable surface Kontaktirajte kvalifikovanog tehničara |
| Pumpa gubi snagu | Curenje zraka u usisnom vodu Nizak nivo vode Začepljen predfilter | Check all connections and O-rings Ensure adequate water level Clean pre-filter basket |
Ako problem i dalje postoji nakon što ste pokušali pronaći ova rješenja, obratite se korisničkoj podršci ili kvalificiranom servisnom tehničaru.
7. Specifikacije
Technical data for the Steinbach SPS 75-1 Filter Pump.

Figure 7.1: Product label detailing the pump's electrical and performance specifications.

Figure 7.2: Dimensional drawing of the pump, indicating height, width, and length.
| Parametar | Vrijednost |
|---|---|
| Broj modela | 040920 |
| Voltage | 230 V |
| Snaga | 450 W |
| Kapacitet pumpe | 8,520 l/h (142 l/min) |
| Max. Pump Height | 9 m |
| Connection Diameter | 32/38 mm |
| Maksimalna temperatura vode | 35°C |
| Maximum Pool Size | 33,000 litre |
| Nivo buke | Pribl. 70 dB |
| Dimenzije proizvoda (D x Š x V) | 45 x 20.5 x 25 cm |
| Težina artikla | 6 kg |
| Materijal | Plastika |
| Izvor napajanja | Corded Electric |
8. Garancija i podrška
Specific warranty details for this product are not provided in this manual. Please refer to your purchase documentation or the manufacturer's official webstranice za informacije o garanciji.
For technical support, spare parts, or service inquiries, please contact Steinbach customer service through their official channels. Always provide your product model number (040920) and purchase date when seeking support.