Antelope Audio 853744004168

Antelope Audio Isochrone Trinity Master Clock User Manual

Model: 853744004168

1. Uvod

The Antelope Audio Isochrone Trinity is a high-definition master clock designed for professional audio environments. It provides precise synchronization for digital audio systems, ensuring optimal performance and sound quality. This manual details the setup, operation, and maintenance of your Isochrone Trinity unit.

Ključne karakteristike uključuju:

  • Universal high-definition synchronization for superior audio.
  • Advanced 4th Generation Acoustically Focused Clocking (AFC) with 64-bit DSP.
  • Military-grade stability with temperature-controlled crystal oscillators.
  • Support for audio up to 384kHz, varispeed functionality, and nine independent generators.
  • Atomic input and USB connectivity for remote control and firmware upgrades.
Antelope Audio Isochrone Trinity Master Clock front view

Slika 1: Prednja strana view of the Antelope Audio Isochrone Trinity Master Clock.

2. Podešavanje

2.1 Raspakivanje i pregled

Carefully remove the Isochrone Trinity from its packaging. Inspect the unit for any signs of damage that may have occurred during transit. Retain the original packaging for future transport or storage.

2.2 Montaža u stalak

The Isochrone Trinity is designed for standard 19-inch rack mounting. Secure the unit using appropriate rack screws. Ensure adequate ventilation around the unit to prevent overheating.

2.3 Priključci stražnje ploče

The rear panel provides all necessary input and output connections for integrating the Isochrone Trinity into your audio system.

Antelope Audio Isochrone Trinity Master Clock rear panel with labels

Figure 2: Rear panel connections of the Antelope Audio Isochrone Trinity Master Clock.

  • AC priključak za napajanje: Connect the provided power cable to this input and a suitable AC power source.
  • DC napajanje: An alternative DC power input (12VDC, 20W).
  • Ulaz za atomski sat: For connecting an external atomic clock source for ultimate precision.
  • Word Clock Inputs: BNC connectors for external word clock synchronization.
  • Video ulaz: BNC connector for video synchronization.
  • Audio A/B/C Word Clock Outputs: Multiple BNC outputs for distributing word clock signals to other devices.
  • Audio A/B/C 256x Word Clock Outputs: Dedicated BNC outputs for 256x word clock signals.
  • AES/EBU Inputs/Outputs: XLR connectors for AES/EBU digital audio signals.
  • S/PDIF Inputs/Outputs: RCA connectors for S/PDIF digital audio signals.
  • USB veza: For remote control, preset management, and firmware updates via a computer.
  • HD Video Outputs: BNC connectors for High Definition video synchronization.
  • SD Video Outputs: BNC connectors for Standard Definition video synchronization (NTSC/PAL).

2.4 Početno napajanje

After making all necessary connections, connect the power cable. The unit will perform a self-test. The front panel display will illuminate, indicating the unit is operational.

3. Uputstvo za upotrebu

The front panel of the Isochrone Trinity provides intuitive controls for managing synchronization settings.

Antelope Audio Isochrone Trinity Master Clock front panel with labels

Figure 3: Front panel controls of the Antelope Audio Isochrone Trinity Master Clock.

  • Dugme za napajanje: Toggles the unit's power on and off.
  • AC/DC Power Indicator: Svijetli kako bi prikazao status napajanja.
  • SOURCE Encoder Knob: Selects the synchronization source.
  • Sample Rate Encoder Knob: Adjusts the output sample rate. The current rate is shown on the Triple Display.
  • Audio Channel Edit Button: Selects which audio channel (A, B, or C) to edit.
  • Trostruki ekran: Prikazuje trenutne sample rates for Audio A, B, and C.
  • Display Dimmer Knob: Adjusts the brightness of the front panel display.
  • HD Select Encoders: Controls for High Definition video synchronization settings.
  • VARISPEED Select Button: Engages or disengages varispeed mode.
  • Split način rada: Allows independent control of different output groups.
  • Pull Up/Down Buttons: Podešava sample rate by small percentages (e.g., +/- 0.1% for USA, +/- 4% for European standards).
  • ATOMIC Lock Light: Indicates when the unit is successfully locked to an atomic clock source.
  • W.C. Lock Light: Indicates when the unit is successfully locked to an external word clock source.
  • Over Clock Light: Indicates an over-clocking condition.
  • Dugme za informacije: Provides access to system information or settings.
  • SD Video Select Button: Selects Standard Definition video synchronization format (NTSC/PAL).

3.1 Basic Synchronization

  1. Ensure all audio devices are connected to the appropriate Word Clock or AES/EBU/S/PDIF outputs of the Trinity.
  2. Koristite SOURCE dugme enkodera to select the desired clock source (e.g., Internal, Atomic, Word Clock Input).
  3. Podesite Sample Rate Encoder Knob za postavljanje traženog sample rate za vaš sistem.
  4. Posmatrajte ATOMIC Lock Light or W.C. Lock Light to confirm successful synchronization.

3.2 Napredne funkcije

For detailed information on Varispeed, Split Mode, and HD/SD video synchronization, refer to the comprehensive online manual available on the Antelope Audio website. The USB connection allows for software control and advanced configuration.

4. Održavanje

The Antelope Audio Isochrone Trinity is designed for reliable operation with minimal maintenance.

  • čišćenje: Za čišćenje vanjske strane uređaja koristite meku, suhu krpu. Izbjegavajte abrazivna sredstva za čišćenje ili rastvarače.
  • Okruženje: Operate the unit in a clean, dry environment, away from direct sunlight, excessive heat, and moisture. Ensure proper ventilation.
  • Ažuriranja firmvera: Periodically check the Antelope Audio website for firmware updates. Updates can be installed via the USB connection.

5. Otkrivanje problema

If you encounter issues with your Isochrone Trinity, consider the following troubleshooting steps:

  • Nema napajanja:
    • Check that the power cable is securely connected to both the unit and the power outlet.
    • Provjerite je li utičnica funkcionalna.
  • No Lock Indication:
    • Ensure the selected clock source (Internal, Atomic, Word Clock) is correctly configured.
    • If using an external source, verify the cable connections and the external device's output.
    • Provjerite sample rate settings on both the Trinity and connected devices.
  • Audio Glitches/Dropouts:
    • Confirm all devices in the audio chain are synchronized to the Isochrone Trinity.
    • Check for proper termination of Word Clock signals if applicable.
    • Ensure all cables are in good condition and securely connected.
  • Problemi sa USB povezivanjem:
    • Pokušajte s drugim USB portom ili kablom.
    • Ensure the correct drivers are installed on your computer.
    • Restart both the Isochrone Trinity and your computer.

If problems persist, consult the Antelope Audio support resources or contact their customer service.

6. Specifikacije

FeatureDetalj
BrandAntelope Audio
ModelIsochrone Trinity (Model No. 853744004168)
Clocking Technology4th Generation Acoustically Focused Clocking (AFC), 64-bit DSP
Tip oscilatoraTemperature-Controlled Crystal Oscillators
Max Sample Rate384 kHz
Generatori9 Independent Generators
InputsAtomic Clock, Word Clock, Video, AES/EBU, S/PDIF, USB
IzlaziWord Clock (Audio A/B/C, 256x), AES/EBU, S/PDIF, HD Video, SD Video
PovezivanjeUSB
Dimenzije19"W x 9"H (Rack-mountable)
Težina10.1 funte
Izvor napajanjaCorded Electric (AC/DC 12VDC, 20W)
Display TypeMulti Display (Digital)

7. Garancija i podrška

For information regarding the warranty period and terms for your Antelope Audio Isochrone Trinity, please refer to the warranty card included with your product or visit the official Antelope Audio website.

For technical support, product registration, or to download the latest drivers and firmware, please visit the Antelope Audio support page: Antelope Audio Support.

Povezani dokumenti - 853744004168

Preview Antelope Audio Isochrone Trinity Korisnički priručnik
Sveobuhvatni vodič za Antelope Audio Isochrone Trinity, univerzalni glavni sat visoke definicije, koji pokriva podešavanje, rad, karakteristike i tehničke specifikacije.
Preview Antelope Audio 10MX Rubidium Atomic Clock User Manual
Sveobuhvatno korisničko uputstvo za Antelope Audio 10MX Rubidium atomski sat, koje detaljno opisuje njegove karakteristike, podešavanje, rad, garanciju, korisničku podršku i tehničke specifikacije za audio profesionalce.
Preview Antelope Audio OCX HD 768kHz HD glavni takt - uputstvo za upotrebu
Korisnički priručnik za Antelope Audio OCX HD, 768kHz HD glavni takt sa 4. generacijom akustički fokusiranog takta (AFC) i kristalnim oscilatorom kontroliranim pećnicom. Obuhvata aktivaciju proizvoda, objašnjenja panela, softver za kontrolu, garanciju, podršku i tehničke specifikacije.
Preview Antelope MP32 32-Channel Microphone Preamp Priručnik za upotrebu
This owner's manual provides detailed information on the Antelope Audio MP32, a 32-channel console-grade microphone preamp. Covers safety, features, installation, operation, technical specifications, and support resources.
Preview Antelope Audio Atlas i8 studijski monitor - uputstvo za upotrebu
Korisnički priručnik za Antelope Audio Atlas i8, izobarični aktivni 3-sistemski studijski monitor. Detalji o karakteristikama, podešavanju, radu, sigurnosnim smjernicama i informacijama o garanciji.
Preview Antelope Audio SRC Stereo Remote Controller User Manual
Comprehensive user manual for the Antelope Audio SRC Stereo Remote Controller, detailing system requirements, product activation, front and rear panel explanations, room calibration features, application usage, customer support information, warranty policy, safety notes, and technical specifications.