Uvod
The Intermatic PE153P is a versatile 3-circuit digital timer designed for automatic control of electrical loads. This 24-hour control mechanism allows for precise scheduling of various applications, including lighting, heating, air conditioning, and pool or spa pumps. Each circuit can manage loads up to 17 amps. This manual provides essential information for the safe installation, programming, operation, and maintenance of your PE153P digital timer.

Slika 1: Intermatic PE153P 3-Circuit Digital Timer. This image shows the timer unit with its rainproof enclosure open, revealing the digital display, control buttons, and wiring terminals. The enclosure is designed to protect the internal components from environmental elements.
Sigurnosne informacije
Uvijek se pridržavajte sljedećih sigurnosnih mjera opreza kako biste smanjili rizik od požara, strujnog udara ili ozljede:
- Installation must be performed by a qualified electrician and in accordance with all national and local electrical codes.
- Disconnect power at the circuit breaker or fuse box before installing or servicing the timer.
- Provjerite da li je tajmer pravilno uzemljen.
- Do not exceed the maximum load ratings for each circuit (17 amps).
- This device is intended for outdoor use and is housed in a rainproof enclosure. Ensure the enclosure is securely closed after installation and servicing.
Instalacija i podešavanje
Montaža kućišta
- Select a suitable location for mounting the timer. The location should be easily accessible for programming and maintenance, and protected from direct sunlight if possible to prolong LCD life.
- Use appropriate mounting hardware (not included) to secure the enclosure to a flat, vertical surface. Ensure the enclosure is level.
Upute za ožičenje
UPOZORENJE: Disconnect power at the main service panel before wiring. Failure to do so may result in serious injury or death.
- Otvorite kućište tajmera.
- Identify the input terminals (LINE 1, LINE 2, NEUTRAL) and output terminals for each of the three circuits (LOAD 1, LOAD 2, LOAD 3).
- Connect the incoming power supply wires to the appropriate input terminals. For 120V operation, connect LINE 1 and NEUTRAL. For 240V operation, connect LINE 1 and LINE 2.
- Connect the load wires for each device you wish to control to the corresponding output terminals.
- Ensure all wire connections are tight and secure. Use copper conductors only, rated for at least 75°C.
- Zatvorite i osigurajte vrata kućišta.
Uputstvo za upotrebu
Initial Power-Up and Time Setting
- Restore power to the timer at the main service panel.
- The LCD display will illuminate. If the display is blank, check power connections.
- Pritisnite PROGRAM dugme za ulazak u režim programiranja.
- Koristite UP i DOLJE arrows to set the current time (hour and minute).
- Pritisnite ENTER za potvrdu svake postavke.
- Podesite trenutni dan u sedmici pomoću UP i DOLJE arrows, then press ENTER.
Rasporedi programiranja
The PE153P offers seven preprogrammed modes and custom programming. Refer to the detailed programming section in the full manual for advanced settings.
- Pritisnite PROGRAM repeatedly to cycle through the available circuits (CIRCUIT 1, CIRCUIT 2, CIRCUIT 3).
- Once the desired circuit is selected, press ENTER to begin setting ON/OFF times.
- Koristi UP i DOLJE arrows to set the ON time, then press ENTER.
- Repeat for the OFF time.
- Select the days of the week for this schedule to be active.
- Pritisnite PROGRAM to save and exit, or to move to the next program event.
Manual Override
To manually turn a circuit ON or OFF outside of its programmed schedule, press the corresponding PRETEŽI button for that circuit. The override will remain active until the next programmed event or until manually cancelled.
Održavanje
The Intermatic PE153P digital timer requires minimal maintenance. Periodically inspect the enclosure for any signs of damage or wear. Ensure the door seal is intact to maintain its rainproof rating. Keep the display and buttons clean and free of debris. No user-serviceable parts are inside the sealed unit beyond the wiring terminals.
Rješavanje problema
| Problem | Mogući uzrok | Rješenje |
|---|---|---|
| Ekran je prazan. | Nema napajanja za jedinicu. | Check circuit breaker/fuse. Verify wiring connections. |
| Opterećenje se ne uključuje/isključuje kako je programirano. | Incorrect programming; Manual override active; Faulty wiring; Load exceeding capacity. | Review programming schedule. Check for active manual override. Inspect wiring. Ensure load is within 17A per circuit. |
| Vrijeme je netačno. | Time not set correctly; Power interruption. | Reset current time and day. The internal battery should maintain time during short power outages. |
If troubleshooting steps do not resolve the issue, contact Intermatic customer support.
Specifikacije
| Model | PE153P |
| Brand | Intermatic |
| Ulazni voltage | 120/240 VAC, 60 Hz |
| Broj krugova | 3 independent circuits |
| Maksimalno opterećenje po krugu | 17 Amps (resistive/inductive), 1000W tungsten, 3 HP |
| Enclosure Type | Rainproof (Type 3R) |
| Ključne karakteristike | LCD Readout, Multivoltage Input/Output, Countdown, Override, Freeze Protection, Heater Protection |
| Težina artikla | 2.55 funte |
Garancija i podrška
Informacije o garanciji
Intermatic products are designed for reliability and performance. For specific warranty details, please refer to the warranty card included with your product or visit the official Intermatic webSačuvajte dokaz o kupovini za slučaj reklamacije.