Intermatic ET1125C

Intermatic ET1125C 24-Hour 30-Amp Electronic Time Switch User Manual

Model: ET1125C

1. Uvod i krajview

The Intermatic ET1125C is a versatile 24-hour electronic time switch designed for precise control of electrical loads. This device offers advanced programming capabilities, including up to 28 events, to-the-minute accuracy, and automatic Daylight Saving Time adjustments. It features a battery backup to maintain programming during power outages and supports a wide input voltage range of 120-277 VAC. The ET1125C is an ideal upgrade from mechanical time switches, providing enhanced functionality and reliability for various applications.

Ključne karakteristike uključuju:

  • Selector switch for input voltage: 120-277 VAC, 50/60 Hz
  • Up to 28 programmable events
  • To-the-minute accuracy for precise scheduling
  • Temporary or permanent manual override options
  • Automatsko podešavanje ljetnog računanja vremena
  • Battery backup for program retention during power loss
Intermatic ET1125C Electronic Time Switch with cover open, showing display and controls

Slika 1: Prednja strana view of the Intermatic ET1125C with the cover open, revealing the digital display and control buttons.

2. Sigurnosne informacije

WARNING: Risk of Electrical Shock. More than one disconnect switch may be required to de-energize the equipment before servicing. Use 10-18 gauge copper conductors rated for at least 75°C (167°F) for all connections.

Installation and servicing of this electronic time switch should only be performed by qualified personnel in accordance with all national and local electrical codes. Always ensure power is disconnected at the circuit breaker before performing any installation, wiring, or maintenance. Failure to follow these instructions may result in serious injury or death.

  • Do not remove the insulator.
  • Osigurajte pravilno uzemljenje.
  • Provjeri voltage settings before applying power.

3. Postavljanje i instalacija

The ET1125C is designed for surface mounting and comes in a Type 1 steel enclosure. Before beginning installation, ensure the mounting location is suitable and all necessary tools and wiring are available.

3.1 Montaža

Mount the enclosure securely to a flat surface using appropriate fasteners. Ensure the enclosure is level and positioned to allow easy access for wiring and programming.

Intermatic ET1125C Electronic Time Switch with cover closed, showing the gray steel enclosure

Figure 2: The Intermatic ET1125C in its Type 1 steel enclosure with the cover closed.

3.2 svtage Izbor

The ET1125C features a selector switch to set the input voltage. This switch must be set correctly to match your electrical system's voltage (120V, 208V, 240V, or 277V) before wiring. Refer to the internal diagram for the exact location of this switch.

Close-up of the internal circuit board of the Intermatic ET1125C, showing the voltage selektorski prekidač

Slika 3: Interni view showing the voltage selector switch on the circuit board.

3.3 Ožičenje

Wiring must be performed by a qualified electrician. The unit supports 2-circuit/30-Amp rating. Connect the incoming power lines (LINE 1, LINE 2) and load lines (LOAD 1, LOAD 2) to the designated terminals. Ensure all connections are secure and comply with local electrical codes. For detailed wiring diagrams, please consult the official installation manual linked in the Support section.

4. Uputstvo za upotrebu

The ET1125C allows for flexible programming and manual control of connected loads.

4.1 Početno podešavanje i podešavanje sata

  1. After power-up, the display will show the current time and date. If incorrect, press the MODE button to enter the clock setting mode.
  2. Koristite + i - buttons to adjust the hour, minute, day, month, and year.
  3. Pritisnite ENTER/NEXT da biste potvrdili svaku postavku i prešli na sljedeću.
  4. Uređaj se automatski podešava na ljetno računanje vremena.

4.2 Programming Events

The ET1125C can store up to 28 ON/OFF events. Each event can be set for specific days of the week or daily.

  1. Pritisnite MODE button until 'PROGRAM' or 'EVENT' appears on the display.
  2. Koristi ENTER/NEXT to cycle through event numbers (e.g., 01 ON, 01 OFF, 02 ON, etc.).
  3. For each event, use the + i - buttons to set the desired time and day(s) of the week.
  4. Specify which load (LOAD 1, LOAD 2, or both) the event applies to using the dedicated ON/OFF buttons for each load during programming.
  5. Pritisnite ENTER/NEXT to save the event and move to the next.
  6. To clear an event, navigate to the event and press CLEAR MEM.
Close-up of the Intermatic ET1125C digital display and control buttons

Slika 4: Detaljno view of the LCD display and programming buttons.

4.3 Ručno prebacivanje

The ET1125C offers both temporary and permanent manual override functions:

  • Privremeno poništavanje: Pritisnite ON/OFF button for LOAD 1 or LOAD 2. The load will switch state until the next scheduled event, at which point it will resume programmed operation.
  • Trajno poništavanje: Pritisnite i držite ON/OFF button for LOAD 1 or LOAD 2 for several seconds until the display indicates 'MANUAL'. The load will remain in its current state, overriding all programmed events, until the manual override is cancelled by pressing the ON/OFF ponovo dugme.

5. Održavanje

The Intermatic ET1125C is designed for minimal maintenance. Periodically inspect the enclosure for any signs of damage or corrosion. Ensure the area around the time switch is clean and free from obstructions.

5.1 Zamjena baterije

The unit uses internal batteries to maintain time and program settings during power outages. If the 'LOW BATT' indicator appears on the display, the batteries should be replaced. Refer to the official installation manual for specific battery type and replacement procedures.

6. Otkrivanje problema

If you encounter issues with your ET1125C, consider the following common troubleshooting steps:

  • Nema prikaza/Nema napajanja: Check the circuit breaker supplying power to the unit. Verify that the voltage selector switch is set correctly.
  • Opterećenje se ne prebacuje: Ensure the unit is in 'AUTO' mode and not in permanent manual override. Check programmed events for correct times and days. Verify wiring connections.
  • Netačno vrijeme/datum: Reset the clock as described in Section 4.1. If the issue persists after power outages, the internal batteries may need replacement.
  • Teškoće s programiranjem: Refer to Section 4.2 for detailed programming steps. Use the CLEAR MEM button to reset events if necessary.

For persistent issues or complex problems, contact Intermatic customer support or consult a qualified electrician.

7. Specifikacije

Broj modelaET1125C
Ulazni voltage120-277 VAC, 50/60 Hz (odabirljivo)
Krugovi2-kružni
Amp Ocjena30 Amp
Enclosure TypeNEMA 1 Steel Enclosure
Broj događajaDo 28
Dimenzije (D x Š x V)3.1" x 5.3" x 8"
Težina artikla2.8 funti
MaterijalČelik
BojaGrey
Vrsta montažeSurface Mount
Stil prekidačaPrekidač na dugme
UPC078275109957

8. Informacije o garanciji

The Intermatic ET1125C Electronic Time Switch comes with a 1-year limited warranty. This warranty covers replacement of the unit due to manufacturing defects but does not include labor costs associated with removal or reinstallation. For full warranty terms and conditions, please refer to the official documentation or contact Intermatic customer service.

9. Customer Support and Further Information

For detailed installation instructions, wiring diagrams, and advanced programming guides, please refer to the official Installation Manual (PDF):

Download Intermatic ET1125C Installation Manual (PDF)

For additional support, technical assistance, or to inquire about service, please visit the official Intermatic webstranice ili kontaktirajte njihov odjel za korisničku podršku.

Povezani dokumenti - ET1125C

Preview Intermatic ET8215C Elektronski tajmer - Tehnički podaci
Detaljne tehničke specifikacije za Intermatic ET8215C elektronski tajmer, astronomski 7-dnevni, 2-kružni elektronski regulator pogodan za primjene od 120-277 VAC u zatvorenom metalnom kućištu.
Preview Upute za instalaciju i korištenje elektroničkog 24-satnog vremenskog prekidača Intermatic serije ET1100
Upute za instalaciju i korištenje Intermatic ET1100 serije elektronskih 24-satnih vremenskih prekidača. Obuhvataju podešavanje, programiranje, specifikacije i informacije o garanciji za modele ET1105C i ET1125C.
Preview Intermatic ET2145 serija elektronskih 4-kružnih 24-satnih vremenskih prekidača - vodič za instalaciju i podešavanje
Comprehensive installation and setup instructions for the Intermatic ET2145C, ET2145CR, and ET2145CP Electronic 4-Circuit 24-Hour Time Switches. Learn how to configure output settings, set date and time, program schedules, manage holidays, and utilize USB data transfer.
Preview Intermatic EJ351 Zidni prekidač s tajmerom za unutarnju upotrebu: Upute za instalaciju i upotrebu
Ovaj dokument pruža upute za instalaciju i korištenje Intermatic EJ351 unutarnjeg zidnog tajmera. Obuhvata specifikacije, ožičenje, metode programiranja (brzo i 24-satno), svakodnevnu upotrebu, rješavanje problema i ograničenu jednogodišnju garanciju.
Preview Intermatic T104 24-satni vremenski prekidač - Specifikacije i upute
Sveobuhvatni vodič za Intermatic T104 vremenski prekidač sa 24-satnim brojčanikom, koji detaljno opisuje njegove specifikacije, električne nazivne vrijednosti, sigurnosna upozorenja, upute za ožičenje, postupke programiranja i smjernice za upotrebu. Uključuje tehničke podatke i savjete za rješavanje problema.
Preview Intermatic DTAV40E2 serija: Podešavanje vremena i programiranje događaja
Vodič za podešavanje vremena, dana u sedmici i programiranje događaja UKLJUČENO/ISKLJUČENO za elektronski tajmer Intermatic serije DTAV40E2.