Uvod

This manual provides detailed instructions for the installation, operation, and maintenance of your Intermatic T104R3 Metal Time Clock. Please read this manual thoroughly before attempting to install or operate the device to ensure safe and efficient use.

The Intermatic T104R3 is a robust 24-hour, 230V, Double-Pole Single-Throw (DPST) time clock designed for various applications requiring scheduled ON/OFF control of electrical loads. It comes enclosed in a durable metal case for protection.

Sigurnosne informacije

WARNING: Risk of Electric Shock. Disconnect power at the circuit breaker or fuse box before installation or servicing. Installation should be performed by a qualified electrician in accordance with all local and national electrical codes.

  • Always ensure power is OFF before working on the timer or connected circuits.
  • Do not exceed the electrical ratings of the timer.
  • This device is intended for permanent installation.
  • Uvjerite se da su svi priključci sigurni i pravilno izolirani.
  • Do not use this device in wet locations unless specifically rated for such use and installed in a weatherproof enclosure.

Sadržaj paketa

  • Intermatic T104R3 Metal Time Clock
  • Uputstvo za upotrebu (ovaj dokument)
  • Mounting hardware (screws, anchors - typically included)

Postavljanje i instalacija

The Intermatic T104R3 is designed for easy installation, but proper electrical knowledge is essential. If you are unsure, consult a qualified electrician.

1. Mounting the Time Clock

  1. Choose a suitable location for mounting the time clock. It should be easily accessible, protected from direct weather (unless installed in a weatherproof enclosure), and close to the electrical circuit it will control.
  2. Open the metal case by unlatching the cover.
  3. Using the mounting holes on the back of the enclosure, mark the desired drilling locations on the wall or mounting surface.
  4. Drill pilot holes and secure the enclosure using appropriate screws and anchors. Ensure the enclosure is level and securely fastened.

2. Upute za ožičenje

IMPORTANT: Ensure power is OFF at the main circuit breaker before proceeding with any wiring.

Intermatic T104R3 Time Clock internal view sa terminalima za ožičenje

Slika 1: Interni view of the Intermatic T104R3 showing the timer mechanism and wiring terminals. Note the "LINE" and "LOAD" connections, and the manual override switch.

  1. Locate the wiring terminals inside the time clock. You will typically find terminals labeled "LINE" (for incoming power) and "LOAD" (for outgoing power to the device being controlled). For the T104R3, which is DPST, there will be two "LINE" terminals and two "LOAD" terminals.
  2. Connect the incoming 230V power supply wires to the "LINE" terminals. Ensure proper polarity if applicable (L1 to L1, L2 to L2).
  3. Connect the wires leading to the electrical load (e.g., pump, lighting) to the "LOAD" terminals.
  4. Ensure all wire connections are tight and secure. Use appropriate wire gauges for the current draw.
  5. After wiring, carefully close the metal case, ensuring no wires are pinched.

Uputstvo za upotrebu

Once installed and wired, the Intermatic T104R3 is ready for programming.

1. Podešavanje trenutnog vremena

  1. Restore power to the time clock at the circuit breaker.
  2. Rotate the large yellow dial clockwise until the current time of day aligns with the "TIME" arrow or indicator on the timer mechanism. The dial represents a 24-hour cycle.

2. Programiranje ciklusa UKLJUČENO/ISKLJUČENO

The T104R3 uses "trippers" or "pins" on the dial to set ON and OFF times. It has 3 settings, implying it can handle multiple ON/OFF cycles.

  • ON Trippers: These are typically green or silver and are inserted into the dial at the desired time for the connected device to turn ON.
  • OFF Trippers: These are typically red or black and are inserted into the dial at the desired time for the connected device to turn OFF.
  1. Insert the ON tripper into the slot on the dial corresponding to the desired ON time.
  2. Insert the OFF tripper into the slot on the dial corresponding to the desired OFF time.
  3. You can set multiple ON/OFF cycles throughout the 24-hour period by adding more trippers. Ensure there is at least one ON and one OFF tripper for each cycle.

3. Ručno prebacivanje

The T104R3 typically includes a manual override switch (often a lever or button) that allows you to temporarily turn the connected device ON or OFF without affecting the programmed schedule. Locate the "MANUAL" switch on the timer mechanism. Moving it to "ON" or "OFF" will override the current program until the next programmed event occurs.

Održavanje

The Intermatic T104R3 is designed for long-term, reliable operation with minimal maintenance.

  • Periodični pregled: Annually inspect the time clock for any signs of wear, damage, or loose connections. Ensure the enclosure is free from dust, debris, or moisture.
  • čišćenje: If necessary, gently wipe the exterior of the case with a dry, soft cloth. Do not use abrasive cleaners or solvents. Ensure the power is disconnected before cleaning.
  • Tačnost vremena: Periodically check if the time clock is keeping accurate time. Minor adjustments to the current time setting may be needed over long periods.

Rješavanje problema

ProblemMogući uzrokRješenje
Time clock not operating / no power.No power to the unit; tripped circuit breaker; loose wiring.Check circuit breaker and reset if tripped. Verify power supply at the terminals with a multimeter (CAUTION: High Voltage). Ensure all wiring connections are secure.
Device not turning ON/OFF at programmed times.Incorrect tripper placement; manual override engaged; incorrect current time setting.Verify ON/OFF trippers are correctly positioned on the dial. Check if the manual override switch is in the desired automatic position. Ensure the current time is accurately set.
Brojčanik tajmera se ne okreće.Motor failure; obstruction.Ensure power is supplied to the unit. Check for any physical obstructions preventing the dial from rotating. If the motor is faulty, the unit may require professional servicing or replacement.

Specifikacije

  • Model: T104R3
  • Brand: Intermatic
  • Voltage: 230V
  • Tip prekidača: Double-Pole Single-Throw (DPST)
  • Ciklus: 24 sata
  • Materijal: metal (futrola)
  • Dimenzije proizvoda: 3.63"D x 6.5"Š x 10.13"H
  • Broj postavki: 3 (referring to tripper capacity)
  • Boja: Multicolor (referring to components, case is typically beige/grey)

Garancija i podrška

Intermatic products are manufactured to high-quality standards. For specific warranty information, please refer to the warranty card included with your product or visit the official Intermatic webSačuvajte račun kao dokaz o kupovini za reklamacije u slučaju reklamacije.

For technical support, troubleshooting assistance, or to inquire about replacement parts, please contact Intermatic Customer Service. Contact information can typically be found on the manufacturer's webweb-mjestu ili na ambalaži proizvoda.

You can visit the official Intermatic Store on Amazon for more products and information: Intermatic Amazon Store

Povezani dokumenti - T104R3

Preview Intermatic ET2705 Series elektronski 7-dnevni vremenski prekidač - vodič za instalaciju i podešavanje
Sveobuhvatni vodič za instalaciju, podešavanje i programiranje elektronskih 1-kružnih sedmodnevnih vremenskih prekidača Intermatic ET2705, ET2705CR i ET2705CP. Obuhvata ožičenje, početno podešavanje, raspoređivanje, konfiguraciju ljetnog računanja vremena, USB prijenos podataka i rješavanje problema.
Preview Upute za upotrebu elektroničkog vremenskog prekidača Intermatic Digi 42 serije
Upute za upotrebu elektronskih vremenskih prekidača Intermatic Digi 42 serije, koje obuhvataju instalaciju, programiranje i rješavanje problema za 24-satne i 7-dnevne rasporede.
Preview Intermatic ET1100 serija elektronskih vremenskih prekidača: Karakteristike, specifikacije i modeli
Detaljne informacije o Intermatic ET1100 seriji 24-satnih elektronskih vremenskih prekidača, uključujući karakteristike, tehničke specifikacije, nazivne vrijednosti kontakata, opcije kućišta i varijacije modela za preciznu kontrolu opterećenja.
Preview Intermatic P7000ME Series Electronic Time Controls Installation and Service Manual
This manual provides detailed instructions for installing, operating, and servicing Intermatic P7000ME Series Electronic Time Controls, including models P7101ME, P7102ME, and P7103ME. It covers safety precautions, specifications, wiring diagrams, programming, and troubleshooting for reliable appliance and equipment control.
Preview Upute za ugradnju Intermatic kućišta vremenskog prekidača otpornog na kišu, potpuno plastičnog
Detaljan vodič za instalaciju Intermatic kućišta vremenskog prekidača otpornog na kišu, izrađenog u potpunosti od plastike, uključujući montažu kućišta, spojeve cijevi i zahtjeve za uzemljenje u skladu s Nacionalnim električnim kodeksom.
Preview Intermatic PE20000 Series Pool/Spa Equipment Control Panel Installation, Operation & Service Manual
Comprehensive guide for installing, operating, and servicing the Intermatic PE20000 Series Pool/Spa Equipment Control Panel, featuring the P1353ME Digital Time Clock. Includes safety instructions, wiring diagrams, operational procedures, and troubleshooting.