Bogen BG-UTI312

Bogen Multi-Zone Page Controller BG-UTI312 User Manual

Brand: Bogen | Model: BG-UTI312

Uvod

The Bogen Multi-Zone Page Controller BG-UTI312 is engineered for multi-zone paging in one-way audio applications, specifically designed for self-amplified speaker systems. Each output is capable of providing audio for up to 150 self-amplified speakers. This unit is compatible with all standard analog port types and offers extensive configuration options for various paging needs. This manual provides essential information for the proper installation, operation, and maintenance of your BG-UTI312 unit.

Postavljanje i instalacija

The BG-UTI312 comes with a pre-installed ZX3 module, providing three zones of paging capability. The system is expandable up to 12 zones by adding additional modules. Installation involves connecting the unit to your existing telephone system and self-ampozvučeni zvučnici.

  • Proširenje zone: The unit is expandable up to 12 zones.
  • Telefonski interfejsi: Supports loop start trunk, ground start trunk, station access (analog ring-up), page port contact closure activation, and page port voice activation.
  • Konfiguracija: Features a simple 2-switch interface setup for initial configuration.
  • Pomoćni kontakti: Programmable activation of AUX contacts is available.
  • Zone Contacts: Includes a C-form contact per zone for flexible integration.
  • Napajanje: Utilizes a 24V DC, 1A internal power supply.
  • Speaker Capacity: Provides audio drive for up to 150 one-way self-amplified speakers per zone.
  • Terminal Strips: Pluggable terminal strips facilitate easy wiring and maintenance.
Front panel of the Bogen BG-UTI312 Multi-Zone Page Controller showing various inputs, outputs, and controls.

Slika 1: This image displays the front panel of the Bogen BG-UTI312, highlighting the music inputs, limiter/threshold controls, interface type selectors, power indicators, and zone connections (1-3, 4-6, 7-9, 10-12).

Uputstvo za upotrebu

The BG-UTI312 offers a range of operational features for comprehensive paging and background music management.

  • Output Limiter: An adjustable output limiter with threshold control and an active indicator helps prevent audio distortion.
  • Muzika u pozadini: Two background music busses are available, selectable per zone. The unit features two high-impedance transformer-isolated background music inputs with stereo combining inputs for these busses.
  • Paging Zone Groups: Up to 24 programmable paging zone groups can be configured, including:
    • All-Call paging zone group.
    • Auto Select paging zone group.
    • Override paging (activated via loop start trunk or page port contact closure).
    • Night Ringer (90V and contact closure activation) with a dedicated zone group.
    • Two Tone Triggers (tone and duration selectable, closure activated) with individual zone groups. Tone options include tone burst, chime, double chime, or slow whoop.
    • Code Calling with a dedicated zone group.
  • biranje: Supports 2 to 5 digit dialing with a flexible dialing plan for zone and zone group numbers.
  • Tonovi: Includes Pre-Announce Tone, Confirmation Tone, and a Setup Tone to assist in volume setting.
  • Programiranje: DTMF programming is used for configuration. DTMF Block helps suppress DTMF tones over the paging system.

Održavanje

The Bogen BG-UTI312 is designed for reliable operation with minimal maintenance.

  • Memorija: Setup data is stored in non-volatile memory, eliminating the need for a backup battery.
  • čišćenje: Uređaj održavajte čistim i bez prašine. Za čišćenje koristite meku, suhu krpu. Izbjegavajte tekuća sredstva za čišćenje.
  • ventilacija: Osigurajte odgovarajuću ventilaciju oko uređaja kako biste spriječili pregrijavanje. Ne blokirajte ventilacijske otvore.
  • Veze: Periodically check all connections to ensure they are secure. The pluggable terminal strips allow for easy inspection and re-connection.

Rješavanje problema

If you encounter issues with your Bogen BG-UTI312, consider the following general troubleshooting steps. The microcontroller-based operation provides stable performance, but basic checks can resolve common problems.

  • Nema napajanja: Verify the power connection and check the fuse rating (1A/125V). Ensure the 24V DC power supply is functioning correctly.
  • No Paging Audio: Check all audio input and output connections. Confirm that the correct zone is selected and that the output limiter is not set too low. Verify telephone interface connections.
  • Iskrivljeni zvuk: Adjust the output limiter threshold. Ensure input levels are not overdriving the system.
  • Incorrect Zone Paging: Review your dialing plan and zone group configurations. Ensure the correct digits are being dialed for the desired zone or group.
  • Background Music Issues: Check background music input connections and ensure the correct bus is selected for the zone. Verify input levels.

For persistent issues, consult a qualified technician or contact Bogen technical support.

Specifikacije

Dimenzije proizvoda19 x 7 x 6.5 inča
Težina artikla0.01 unce
ProizvođačBogen
Broj modelaBG-UTI312
Napajanje24V DC, 1A (internal)
Zone Capacity3 to 12 zones (expandable with modules)
Speaker CapacityUp to 150 one-way self-amplified speakers per zone
Paging Zone GroupsDo 24 programabilnih
MemorijaNon-volatile for setup data
Alternativa view of the Bogen BG-UTI312 Multi-Zone Page Controller.

Slika 2: This image provides another perspective of the Bogen BG-UTI312, showing the overall chassis and the arrangement of its various connection points and controls.

Informacije o garanciji

The Bogen Multi-Zone Page Controller BG-UTI312 comes with a 2 godine garancije. Please retain your proof of purchase for warranty claims. For detailed terms and conditions, refer to the official warranty documentation provided with your product or visit the Bogen website.

Podrška

For technical assistance, product inquiries, or service requests, please contact Bogen customer support. Refer to the contact information provided on the Bogen official website or in the packaging materials for the most current support channels.

Povezani dokumenti - BG-UTI312

Preview Bogen UTI312 Uputstvo za instalaciju i upotrebu zonskog kontrolera i univerzalnog telefonskog interfejsa
Uputstvo za instalaciju i upotrebu Bogen UTI312 zonskog kontrolera sa univerzalnim telefonskim interfejsom, u kojem se detaljno opisuju njegove karakteristike, podešavanje i operativne smjernice za višezonske sisteme pozivanja i signalizacije.
Preview Bogen TPU Series Telephone Paging Amplifiers: Installation and Use Manual
Comprehensive installation and use manual for Bogen TPU35B, TPU60B, TPU100B, and TPU250 telephone paging amplifiers, covering setup, wiring, operation, and specifications.
Preview Bogen MCP35A Glavna Kontrolna Panel: Uputstvo za Instalaciju i Upotreba
Ovaj priručnik pruža detaljne upute za instalaciju, rad i tehničke specifikacije za Bogen MCP35A glavnu kontrolnu ploču, svestrani sistem za dvosmjernu komunikaciju i distribuciju programa u različitim okruženjima.
Preview Bogen IH8A Reentrant zvučnik sa hornom - Specifikacije proizvoda i instalacija
Sveobuhvatni detalji o Bogen IH8A reentrantnom zvučniku s hornom, uključujući njegove karakteristike, tehničke specifikacije, vodič za montažu i instalaciju te informacije o ograničenoj garanciji.
Preview Vodič za konfiguraciju Bogen Nyquist VoIP interfonskog modula (NQ-GA10P, NQ-GA10PV)
Detaljan vodič za konfiguraciju Bogen-ovih Nyquist NQ-GA10P i NQ-GA10PV VoIP interfonskih modula. Obuhvata podešavanje, mrežne postavke, ažuriranja firmvera i samostalni rad za IP paging i audio distribucijske sisteme.
Preview Bogen VAR1 Voice-Activated Relay: Technical Specifications and Operation
Detailed specifications, installation, operation, and warranty information for the Bogen VAR1 Voice-Activated Relay, a DPDT relay device for audio signal activation and muting.