ICM Controls ACS-8

ICM Controls ACS-8 8-pinska oktalna priključna baza - korisnički priručnik

Model: ACS-8 | Brand: ICM Controls

1. Proizvod je gotovview

The ICM Controls ACS-8 is an 8-pin octal plug-in base designed for use with various plug-in style phase monitors and timers. It provides a secure and reliable connection point for compatible devices, ensuring proper electrical contact and mechanical stability.

ICM Controls ACS-8 8-Pin Octal Plug-in Base

Image: The ICM Controls ACS-8 8-Pin Octal Plug-in Base, showing its grey housing, eight pin receptacles, and screw terminals for wiring connections. A red locating key is visible on one side.

2. Ključne karakteristike

  • Relay Socket: Functions as a robust relay socket for plug-in devices.
  • 8-Pin Octal Design: Specifically designed for 8-pin octal plug-in components.
  • Locating Key: Features a locating key to ensure correct orientation and prevent improper insertion of compatible devices.
  • Kompatibilnost: Intended for use with ICM408 three-phase monitors and ICM500 Series multi-mode timers.

3. Postavljanje i instalacija

Installation of the ACS-8 base involves securing it to a panel or enclosure and wiring the appropriate electrical connections. Ensure all power is disconnected before beginning installation.

  1. Montaža: Secure the ACS-8 base to a stable surface using appropriate fasteners through its mounting holes.
  2. Ožičenje: Connect the electrical wires to the screw terminals on the base. Refer to the wiring diagram of the specific phase monitor or timer being used for correct terminal assignments. Ensure all connections are tight and secure.
  3. Umetanje uređaja: Align the compatible 8-pin octal phase monitor or timer with the ACS-8 base, ensuring the locating key on the device matches the slot on the base. Gently push the device into the base until it is fully seated.
  4. Uključeno: Once the device is securely installed and all wiring is verified, restore power to the system.

Važno: Always consult the specific wiring diagrams and safety instructions provided with the phase monitor or timer you intend to use with this base.

4. Principi rada

The ACS-8 functions as a passive interface, providing the necessary electrical and mechanical connection for an 8-pin octal plug-in device. It does not perform any active monitoring or timing functions itself. Its operation is entirely dependent on the functionality of the device plugged into it, such as an ICM408 three-phase monitor or an ICM500 Series multi-mode timer.

Once a compatible device is correctly inserted and powered, the ACS-8 base facilitates the electrical signals and power flow required for the device to operate as intended.

5. Održavanje

The ICM Controls ACS-8 8-Pin Octal Plug-in Base is designed for minimal maintenance. Regular inspection is recommended to ensure optimal performance.

  • Vizuelni pregled: Periodically check the base for any signs of physical damage, discoloration, or loose connections.
  • čišćenje: If necessary, gently clean the exterior of the base with a dry, soft cloth. Do not use abrasive cleaners or solvents. Ensure power is disconnected before cleaning.
  • Integritet veze: Verify that the plug-in device is securely seated and that all wired connections remain tight.

6. Otkrivanje problema

If the system incorporating the ACS-8 base is not functioning as expected, consider the following troubleshooting steps:

  • Nema napajanja uređaja: Verify that power is supplied to the base and that all wiring connections are correct and secure. Check circuit breakers or fuses.
  • Uređaj ne funkcioniše: Ensure the plug-in device (monitor/timer) is fully and correctly seated in the ACS-8 base. The locating key should ensure proper orientation.
  • Intermitentni rad: Check for loose wiring connections at the screw terminals of the base. Ensure the plug-in device is not loose in its socket.
  • Incorrect Device: Confirm that the device being plugged into the ACS-8 is an 8-pin octal type and compatible with the base.

If issues persist after performing these checks, consult the user manual for the specific phase monitor or timer being used, or contact ICM Controls technical support.

7. Specifikacije

AtributVrijednost
Broj modelaACS-8
Dimenzije proizvoda2 x 2 x 2 inča
Težina artikla1.6 unce
ProizvođačICM kontrole
KompatibilnostICM408 three-phase monitors, ICM500 Series multi-mode timers

8. Garancija i podrška

For specific warranty information regarding the ICM Controls ACS-8, please refer to the documentation provided with your purchase or visit the official ICM Controls webstranica. Garantni uslovi obično pokrivaju nedostatke u materijalima i izradi pri normalnoj upotrebi.

For technical support, product inquiries, or assistance with troubleshooting beyond the scope of this manual, please contact ICM Controls customer service directly. Contact information can usually be found on the manufacturer's weblokacija ili ambalaža proizvoda.

Povezani dokumenti - ACS-8

Preview ICM401A trofazni monitor: Vodič za instalaciju zaštite od gubitka faze i inverzije faze
Detaljan vodič za instalaciju i specifikacije za ICM401A trofazni vod vol.tage monitor od ICM Controls. Saznajte više o njegovom radu, rješavanju problema i sigurnosnim mjerama opreza za zaštitu od gubitka faze i inverzije.
Preview ICM402 3-fazni monitor: Karakteristike, specifikacije i ožičenje
Detaljne informacije o ICM402 trofaznom monitoru, uključujući njegove karakteristike, tehničke specifikacije i dijagrame ožičenja. Ovaj uređaj štiti od gubitka faze, inverzije faze i fazne neravnoteže, idealan za kompresore.
Preview Vodič za instalaciju univerzalnog regulatora pritiska ICM325A za jednofazni sistem
Vodič za instalaciju, rad i primjenu univerzalnog jednofaznog regulatora pritiska ICM325A. Poseduje NFC tehnologiju za programiranje putem ICM Omni aplikacije, dvostruke senzorske ulaze, bypass toplotne pumpe i univerzalni regulator protoka.tage.
Preview ICM450A i ICM450A PLUS+ Programabilni trofazni linijski regulator jačine zvukatage Monitors - Installation, Operation & Application Guide
This guide provides detailed specifications, parameters, installation instructions, fault conditions, troubleshooting steps, and warranty information for the ICM450A and ICM450A PLUS+ programmable 3-phase line voltage monitors from ICM Controls.
Preview ICM517A Surge Protective Device Installation, Operation & Application Guide
Comprehensive guide for installing, operating, and applying the ICM517A Type 2 Surge Protective Device. Includes specifications, wiring diagrams, safety warnings, and warranty information from ICM Controls.
Preview Vodič za instalaciju i upotrebu univerzalnog jednofaznog regulatora pritiska ICM325A
Detaljan vodič za instalaciju, rad i rješavanje problema ICM325A jednofaznog univerzalnog regulatora pritiska kompanije ICM Controls. Ima NFC povezivost, univerzalni regulator...tage, i promjenjivu kontrolu brzine ventilatora za HVAC sisteme.