1. Uvod
This manual provides essential instructions for the installation, operation, and maintenance of the ADTRAN MX2800 M13/STS-1 Multiplexer Redundant AC Power Supply (Model 1202289L1). Please read this manual thoroughly before attempting to install or operate the device to ensure proper function and safety.
2. Sigurnosne informacije
Pridržavajte se sljedećih sigurnosnih mjera opreza kako biste spriječili ozljede i oštećenje opreme:
- Isključivanje struje: Always disconnect power to the MX2800 chassis before installing or removing the power supply unit.
- Kvalificirano osoblje: Instalaciju i servisiranje treba obavljati samo kvalificirano osoblje.
- ventilacija: Ensure adequate ventilation around the power supply and the MX2800 chassis to prevent overheating.
- Uslovi okoline: Operate the device within specified environmental limits (temperature, humidity).
- uzemljenje: Ensure the MX2800 chassis is properly grounded.
3. Sadržaj paketa
Provjerite da li su sve stavke prisutne u paketu:
- ADTRAN MX2800 M13/STS-1 Multiplexer Redundant AC Power Supply (Model 1202289L1)
- Documentation (this manual or similar)
- Note: Power cords or mounting hardware may be sold separately or included with the main MX2800 unit.
4. Proizvod je gotovview
The ADTRAN MX2800 M13/STS-1 Multiplexer Redundant AC Power Supply is designed to provide reliable power to the ADTRAN MX2800 chassis. This 30-watt AC power supply offers redundancy, enhancing the overall system's uptime and reliability by providing a backup power source in case of a primary power supply failure. It is specifically engineered for seamless integration with the MX2800 M13/STS-1 Multiplexer system.

Slika: Front view of the ADTRAN MX2800 Redundant AC Power Supply. This image displays the physical unit, typically showing its connectors and form factor designed for integration into the MX2800 chassis.
5. Podešavanje
Follow these steps to install the AC Power Supply into the MX2800 chassis:
- Iskljuciti: Ensure the MX2800 chassis is completely powered off and disconnected from all power sources.
- Pronađite slot: Identify the designated power supply slot(s) in the MX2800 chassis. Refer to the MX2800 chassis manual for specific slot locations.
- Insert Power Supply: Carefully slide the AC Power Supply into the vacant slot until it is fully seated. Ensure the connectors align properly.
- Sigurnosna jedinica: Use any provided thumbscrews or locking mechanisms to secure the power supply in place within the chassis.
- Povežite AC napajanje: Connect a suitable AC power cord (not included) to the power supply's AC inlet and then to a grounded electrical outlet.
- Uključeno: Reconnect power to the MX2800 chassis and power it on. Observe the power supply's indicator lights for proper operation.
6. Uputstvo za upotrebu
Once installed and powered on, the redundant AC power supply operates automatically. Key operational aspects include:
- Pokazatelji napajanja: Check the status indicator lights on the power supply. A solid green light typically indicates normal operation. Refer to the MX2800 chassis manual for specific indicator meanings.
- redundantnost: If two power supplies are installed, they operate in a redundant configuration. Should one unit fail, the other automatically takes over, ensuring continuous operation of the MX2800.
- Hot-swapable: This power supply is designed to be hot-swappable, meaning it can be replaced without powering down the entire MX2800 chassis, provided another operational power supply is present. Always follow proper hot-swap procedures outlined in the MX2800 chassis manual.
7. Održavanje
The ADTRAN MX2800 AC Power Supply requires minimal maintenance. Regular checks can help ensure its longevity and reliable performance:
- Vizuelni pregled: Periodically inspect the power supply and its connections for any signs of damage, loose cables, or excessive dust accumulation.
- čišćenje: If dust is present, gently clean the exterior of the power supply and the chassis ventilation openings using a soft, dry cloth or compressed air. Ensure the unit is powered off and disconnected before cleaning.
- Firmware: Power supplies typically do not have user-upgradable firmware. Any firmware updates would be part of the main MX2800 chassis system.
8. Otkrivanje problema
Ako imate problema s napajanjem, razmotrite sljedeće:
- No Power/No Indicators:
- Verify the AC power cord is securely connected to both the power supply and a working electrical outlet.
- Check the circuit breaker or fuse for the electrical outlet.
- Ensure the power supply is fully seated in its slot within the MX2800 chassis.
- Indikator kvara:
- A fault indicator (often amber or red) suggests an internal issue or an environmental problem.
- If redundant power supplies are installed, the system should continue operating on the healthy unit.
- Attempt to reseat the power supply. If the fault persists, the unit may require replacement.
- Nestabilnost sistema:
- If the MX2800 system experiences unexpected shutdowns or instability, and a power supply fault is indicated, replace the faulty power supply.
- Ensure the power supply is compatible with your specific MX2800 chassis model.
For further assistance, contact ADTRAN technical support.
9. Specifikacije
| Broj modela | 1202289L1 |
| Vrsta proizvoda | Redundantno AC napajanje |
| Brand | ADTRAN |
| Output Wattage | 30 Watts |
| Ulazni voltage | AC (Specific voltage range typically found on unit label) |
| Dimenzije (D x Š x V) | 10 x 6 x 3 inča |
| Težina artikla | 0.6 funte (otprilike 9.6 unce) |
| Kompatibilni uređaji | ADTRAN MX2800 M13/STS-1 Multiplexer (Servers) |
| ASIN | B000067OBM |
| UPC | 607565007804 |
10. Garancija i podrška
For information regarding the warranty coverage for your ADTRAN MX2800 M13/STS-1 Multiplexer Redundant AC Power Supply, please refer to the warranty documentation provided with your original MX2800 system or visit the official ADTRAN website. For technical support, troubleshooting assistance beyond this manual, or to inquire about replacement parts, please contact ADTRAN customer service or your authorized ADTRAN reseller.
ADTRAN Contact Information:
- Please refer to the official ADTRAN webstranicu za najnovije kontakt podatke.